Loading...
*  Abstract W MP12: Changing Policies for Blood Pressure Management in Spontaneous Intracerebral Hemorrhage | Stroke
Thank you for your interest in spreading the word on Stroke.. NOTE: We only request your email address so that the person you ... Conclusion: Stroke centers have rapidly adopted changes in blood pressure management in intracerebral hemorrhage in advance of ... Purpose: To determine the current level of adoption by stroke centers of lower targets for blood pressure in patients with ... Our mission is to build healthier lives, free of cardiovascular diseases and stroke. That single purpose drives all we do. The ...
  http://stroke.ahajournals.org/content/45/Suppl_1/AWMP12
*  Cardiac output - pulse contour analysis vs. pulmonary artery thermodilution - ØStergaard - 2006 - Acta Anaesthesiologica...
Elizabeth J. Bridges, Arterial Pressure-Based Stroke Volume and Functional Hemodynamic Monitoring, The Journal of ... that estimated the left ventricular stroke volume, beat-to-beat, from the pressure curve of the aorta. The PiCCOplus, however, ... Post-operatively, the volume of thermal indicator injections was 10 ml.. The injections were by hand and always completed ... The ability of the PiCCO system to track haemodynamic changes during volume loading has recently been published (14). ...
  http://onlinelibrary.wiley.com/doi/10.1111/j.1399-6576.2006.01080.x/full
*  Experimental and numerical study on optimal spot-electrodes arrays in transthoracic electrical impedance cardiography.
... cardiography is a simple technique for the non-invasive and continuous monitoring of stroke volume or cardiac output by ... 7398015 - Pulsed doppler echocardiographic measurement of beat-to-beat changes in stroke volume i.... 8469715 - Converting ... cardiography is a simple technique for the non-invasive and continuous monitoring of stroke volume or cardiac output by ... Annual Conference Volume: 2007 ISSN: 1557-170X ISO Abbreviation: Conf Proc IEEE Eng Med Biol Soc Publication Date: 2007 ...
  http://www.biomedsearch.com/nih/Experimental-numerical-study-optimal-spot/18003025.html
*  Estimation of Errors in Determining Intrathoracic Blood Volume Using the Single Transpulmonary Thermal Dilution Technique in...
In the shock group, the shock phase was associated with a significant reduction in CO, stroke volume, and mean arterial ... We estimated blood volume on the basis of 75 ml/kg based on previous studies in our laboratory22 and the volume of blood ... Third, volume of distribution measured using the dye-dilution technique refers to the respective volume from the point of ... Whether this central blood volume should be referred to as global end-diastolic volume, as suggested in current literature and ...
  http://anesthesiology.pubs.asahq.org/article.aspx?articleid=1923704
*  Abstract 302: Transthoracic Impedance Is Poorly Predicted by Patient Characteristics but Significantly Reduced by Placement of...
Our mission is to build healthier lives, free of cardiovascular diseases and stroke. That single purpose drives all we do. The ...
  http://circ.ahajournals.org/content/126/Suppl_21/A302
*  Patent US7329226 - System and method for assessing pulmonary performance through transthoracic ... - Google Patents
McKay et al., "Instantaneous Measurement of Left and Right Venticular Stroke Volume and Pressure-Volume Relationships with an ... which is the volume inhaled or exhaled in normal quiet breathing; inspiratory reserve volume (IRV), which is the maximum volume ... the pulmonary volume 163 for a healthy person is shown. FEV1.0 164 is measured at a one-second interval 166. The volume expired ... Pulmonary volume 163, 183, 203 is respectively plotted as a function of time. For clarity, the pulmonary volumes have been ...
  http://www.google.com/patents/US7329226?dq=7,343,408
*  Why Did Fluid Therapy Kill My Patient? - WSAVA2008 - VIN
Adding large volumes of crystalloid to such patients can often cause pulmonary edema and/or pleural effusion. Therefore, it is ... Volume resuscitation can be a frequent cause of circulatory fluid overload even if the administered dose is within acceptable ... Acute hypernatremia with ECF (extracellular fluid space) volume expansion is usually seen in patients receiving excess amounts ... Providing fluid therapy for the oliguric/anuric patient first entails replacing dehydration volumes followed by precise ...
  http://www.vin.com/apputil/content/defaultadv1.aspx?pId=11268&id=3866703
*  Impedance cardiography - Wikipedia
Systemic (global) blood flow parameters are (a) the blood flow per heartbeat, the Stroke Volume, SV [ml/beat], and (b) the ... induced level of contractility is modulated by variation of intravascular volume (volume expansion or volume reduction/diuresis ... such as Stroke Volume, SV, Heart Rate, HR, Cardiac Output, CO, Ventricular Ejection Time, VET, Pre-ejection Period and used to ... stroke volume, systemic vascular resistance, thoracic fluid content, acceleration index, and systolic time ratio. What is TEB ...
  https://en.wikipedia.org/wiki/Impedance_cardiography
*  Definitions of stroke volume - OneLook Dictionary Search
stroke volume: online medical dictionary [home, info] *stroke volume: Medical dictionary [home, info] *Stroke volume, Volume, ... stroke volume: Encyclopedia [home, info] Medicine (6 matching dictionaries). *Stroke volume, Volume, stroke: MedTerms.com ... stroke volume: Merriam-Webster.com [home, info] *stroke volume: Dictionary.com [home, info] *Stroke volume: Wikipedia, the Free ... stroke volume: Dictionary/thesaurus [home, info] Business (2 matching dictionaries). *stroke volume: Legal dictionary [home, ...
  https://www.onelook.com/?w=stroke+volume&ls=a
*  Stroke volume - Wikipedia
In cardiovascular physiology, stroke volume (SV) is the volume of blood pumped from the left ventricle per beat. Stroke volume ... which is stroke volume divided by end-diastolic volume. Because stroke volume increase in certain conditions and disease states ... Stroke volume is an important determinant of cardiac output, which is the product of stroke volume and heart rate, and is also ... Heart rate and Stroke Volume are unfixed. EF math needs to be more transparent. Men, on average, have higher stroke volumes ...
  https://en.wikipedia.org/wiki/Stroke_volume
*  Clinically significant change in stroke volume in pulmonary hypertension.
Stroke volume directly reflects right ventricular function in response to its load, w ... Stroke volume is probably the best hemodynamic parameter because it reflects therapeutic changes and contains prognostic ... The change in stroke volume was related to the change in 6MWT. Using the anchor-based method, an MID of 10 mL in stroke volume ... 15096094 - Stroke and blood pressure variability.. 1521314 - Reliability of doppler echocardiographic stroke volume measurement ...
  http://www.biomedsearch.com/nih/Clinical-significant-change-stroke-volume/20864614.html
*  Stroke Volume/Pulse Pressure Ratio and Cardiovascular Risk in Arterial Hypertension | Hypertension
The ratio of stroke volume to pulse pressure (SV/PP) has been proposed as an indirect measure of total arterial compliance,1 2 ... Stroke Volume/Pulse Pressure Ratio and Cardiovascular Risk in Arterial Hypertension. Giovanni de Simone, Mary J. Roman, Michael ... Stroke Volume/Pulse Pressure Ratio and Cardiovascular Risk in Arterial Hypertension. Giovanni de Simone, Mary J. Roman, Michael ... Stroke Volume/Pulse Pressure Ratio and Cardiovascular Risk in Arterial Hypertension. Giovanni de Simone, Mary J. Roman, Michael ...
  http://hyper.ahajournals.org/content/33/3/800
*  Patent US7024244 - Estimation of stroke volume cardiac output using an intracardiac pressure sensor - Google Patents
The pressure monitor may control a delivery of therapy by an implantable medical device as a function of the stroke volume or ... The pressure monitor may calculate the stroke volume or cardiac output using the velocity-time integral. ... such as a stroke volume or a cardiac output, as a function of a pressure in the heart. A pressure monitor may measure pressure ... Stroke volume is the volume of blood pumped out of the heart in one beat. Cardiac output is the volume of blood pumped out of ...
  http://www.google.com/patents/US7024244?dq=6,272,646
*  A Model Simulation for Decreased Left Ventricular Stroke Volume in Obstructive Sleep-Disordered Breathing
... Ernesto Goldman ... Ernesto Goldman, "A Model Simulation for Decreased Left Ventricular Stroke Volume in Obstructive Sleep-Disordered Breathing," ... Volume 2012 (2012), Article ID 926345, 5 pages. http://dx.doi.org/10.5402/2012/926345. Research Article ...
  https://www.hindawi.com/journals/isrn/2012/926345/cta/
*  Stroke volume | Article about stroke volume by The Free Dictionary
... the diastolic volume of the left ventricle minus the volume of blood in the... Explanation of stroke volume ... Find out information about stroke volume. The amount of blood pumped during each cardiac contraction; quantitatively, ... Stroke volume , Article about stroke volume by The Free Dictionary https://encyclopedia2.thefreedictionary.com/stroke+volume ... stroke volume. Also found in: Dictionary, Thesaurus, Medical, Legal, Financial, Acronyms, Wikipedia. stroke volume. [′strōk ‚ ...
  http://encyclopedia2.thefreedictionary.com/stroke+volume
*  Patent US5058583 - Multiple monopolar system and method of measuring stroke volume of the heart - Google Patents
... voltage between one of the monopolar electrodes in the ventricle and the pacemaker case and for calculating stroke volume ... includes a constant-current source for current injection into the volume of blood in the patient's ventricle and an impedance ... A multiple monopolar system and method for measuring stroke volume of a patient's heart. An intracardiac impedance catheter is ... measuring the patient's stroke volume during said induced variations in heart rate, said step of measuring stroke volume ...
  http://www.google.co.uk/patents/US5058583
*  Pressure-Flow Studies in Man: Effect of Respiration on Left Ventricular Stroke Volume | Circulation
... an immediate fall in stroke volume with the onset of inspiration; and (2) a subsequent increase in stroke volume presumably due ... Pressure-Flow Studies in Man: Effect of Respiration on Left Ventricular Stroke Volume. JEROME RUSKIN, ROBERT J. BACHE, JUDITH C ... In normals, stroke volume, systolic pressure, and pulse pressure fell an average of 7, 3 and 11% (P , 0.01), respectively, ... After breath-holding, stroke volume also fell immediately with the onset of inspiration in both groups. These results are ...
  http://circ.ahajournals.org/content/48/1/79
*  Contribution of Stroke Volume to the Change in Pulse Pressure Pattern With Age | Hypertension
... cardiac output gradually decreases at the expense of stroke volume.5 The age-related decrease in stroke volume, by reducing ... overcame the effect of the decreasing stroke volume on pulse pressure, explaining the lack of correlation between stroke volume ... without significant influence of stroke volume. Thus, in hypertensive men, the age-related change in stroke volume ... 12 Stroke index was obtained by dividing stroke volume by meters squared. Pulse pressure was calculated as the difference ...
  http://hyper.ahajournals.org/content/34/4/808
*  Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery.
Fluid responsiveness was defined as an increase in stroke volume index (SVI) ,10%. PPV(ref), PPV(auto), SVV(auto), and SVI ( ... and stroke volume variation (SVV(auto)) (FloTrac/Vigileo) to predict fluid responsiveness during abdominal surgery. METHODS: We ... Title: British journal of anaesthesia Volume: 103 ISSN: 1471-6771 ISO Abbreviation: Br J Anaesth Publication Date: 2009 Nov ...
  http://www.biomedsearch.com/nih/Automated-pulse-pressure-stroke-volume/19797246.html
*  The utility of intra-operative three-dimensional transoesophageal echocardiography for dynamic measurement of stroke volume. |...
... of this study were to compare stroke volume measured by three-dimensional transoesophageal echocardiography with stroke volume ... The utility of intra-operative three-dimensional transoesophageal echocardiography for dynamic measurement of stroke volume.. [ ... We used Bland-Altman analysis to assess the agreement between the stroke volume measured by three-dimensional transoesophageal ... Measurement of left ventricular stroke volume and cardiac output is very important for managing haemodynamically unstable or ...
  https://www.sigmaaldrich.com/catalog/papers/25265890
*  "The Effect of Selective Hypothermia on Stroke Volume" by Thomas K. Mattingly
Mean stroke volumes were reduced by 38.4-44.2% in the hypothermia group (p=0.292). Selective moderate hypothermia can be ... We studied the effect of selective hypothermia on stroke volumes in adult domestic swine. Under general anesthesia, one MCA was ... A promising reduction in stroke volumes is seen. Further study is warranted. ... Mean stroke volumes were reduced by 38.4-44.2% in the hypothermia group (p=0.292). Selective moderate hypothermia can be ...
  https://ir.lib.uwo.ca/etd/1284/
*  Measuring Cardiac Output and Stroke Volume Using the Physioflow Impedance Device in Pregnant Patients - Full Text View -...
Measuring Cardiac Output and Stroke Volume Using the Physioflow Impedance Device in Pregnant Patients. This study has been ... The etiology of hypotension is multi-factorial,and it is postulated that decreases in cardiac output (CO), stroke volume (SV) ... Pilot Study Measuring Cardiac Output and Stroke Volume Using Non-Invasive Thoracic Impedance With the Physioflow Impedance ... Continuous measurement of cardiac output (CO), stroke volume (SV) and/or systemic vascular resistance (SVR) changes. [ Time ...
  https://clinicaltrials.gov/show/NCT00573274
*  Cardiac output and stroke volume variation measured by the pulse wave transit time method: a comparison with an arterial...
Cardiac output and stroke volume variation measured by the pulse wave transit time method: a comparison with an arterial ... Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and ... CO values measured using esCCO and APCO were collected every 6 h, and stroke volume variation (SVV) data were obtained every ... Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation. ...
  https://link.springer.com/article/10.1007/s10877-018-0171-y
*  "LBNP and Stroke Volume" by Edward J. St. John Jr. and William H. Cooke
... and stroke volume (-1.3 ml/mmHg) to the level of LBNP applied were not dependent on decompression rate (all ANOVA comparisons, ... and stroke volumes (-66%; p ≤ .05). The magnitude of changes induced by LBNP were not different between groups (p ≥ .4). Slopes ... inert gas rebreathing to calculate stroke volume) during continuous LBNP applied at three different decompression rates (n = 15 ... and stroke volume (-1.3 ml/mmHg) to the level of LBNP applied were not dependent on decompression rate (all ANOVA comparisons, ...
  https://digitalcommons.wku.edu/ijesab/vol2/iss7/63/
*  Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin...
... stroke volume variation (SVV; d), stroke volume e and cardiac index (CI; f) during Trendelenburg (TB) and reversal to neutral ... stroke volume variation (SVV), stroke volume (SV) or cardiac index (CI), Patients were categorized according to age (,55 or ≥55 ... enabling to subsequent determination of stroke volume, cardiac index, and stroke volume variation using the Nexfin CO-trek- ... Stroke volume variation (SVV) was defined as the relative variation between the highest (SVmax) and lowest (SVmin) stroke ...
  https://link.springer.com/article/10.1007%2Fs10877-015-9759-7