Loading...


*  Market Driven At Steady CAGR with Rising Demand from Global Cardiac Monitoring & Cardiac Rhythm Management Industry. | Medgadget
6.4.2.2 Transvenous implantable cardioverter defibrillator (T-ICDs). 6.4.2.2.1 Single-chamber ICDs ... defibrillators segment commands the global market due to availability of improved defibrillators, increasing cardiovascular ... patients and care providers create better solutions, outcomes and lower healthcare costs worldwide. ... 5.5.1.1 Single lead. 5.5.1.2 3-6 lead. 5.5.1.3 12-lead ... 6.3.3.1 Single-Chamber Pacemakers. 6.3.3.2 Dual-Chamber ...
  https://www.medgadget.com/2017/04/market-driven-at-steady-cagr-with-rising-demand-from-global-cardiac-monitoring-cardiac-rhythm-management-industry.html
*  A simplified, single-lead unipolar transvenous cardioversion-defibrillation system. | Circulation
BACKGROUND Transvenous implantable cardioverter-defibrillators provide significant advantages in the treatment of patients with ... A simplified, single-lead unipolar transvenous cardioversion-defibrillation system.. G H Bardy, G Johnson, J E Poole, G L ... A simplified, single-lead unipolar transvenous cardioversion-defibrillation system.. G H Bardy, G Johnson, J E Poole, G L ... A simplified, single-lead unipolar transvenous cardioversion-defibrillation system.. G H Bardy, G Johnson, J E Poole, G L ...
  http://circ.ahajournals.org/content/88/2/543
*  Interventional Electrophysiology in Patients With Congenital Heart Disease | Circulation
Implantable cardioverter defibrillators in adults with congenital heart disease: a single center experience. Pacing Clin ... Lead Placement. Transvenous access for pacemaker or defibrillator leads in CHD often is difficult. The challenge is well ... Implantable Defibrillators in CHD. Implantable defibrillators are being used with increasing frequency in the CHD population. ... Transvenous dual-chamber systems are possible in most cases, except for patients with significant intracardiac shunts, a single ...
  http://circ.ahajournals.org/content/115/25/3224
*  Patente WO2004091715A1 - Methods and systems involving subcutaneous electrode positioning relative to ... - Google Patentes
Implantable cardioverter/defibrillators (ICDs) have been used as an effective treatment for patients with serious cardiac ... In addition, this system would have advantages for use in patients for whom transvenous lead systems cause complications. Such ... Another configuration (Figures 4B and 4C) illustrate a single ring and a single coil that may be used for integrated bipolar or ... Implantable cardiac rhythm management systems have been used as an effective treatment for patients with serious arrhythmias. ...
  http://www.google.es/patents/WO2004091715A1?cl=en
*  An 8-year single-centre experience of cardiac resynchronisation therapy: procedural success, early and late complications, and...
... or the incidence of these complications in patients with different heart failure aetio ... Long-term LV lead performance was comparable with that of right atrial and ventricular leads.CONCLUSION: Transvenous ... The mean age of patients was 65 ± 15 years, 31% were female. The majority of devices (70%) were CRT-defibrillators. Left ... 21041579 - Meta-analysis: age and effectiveness of prophylactic implantable cardioverter-defibrill.... 18534279 - The new and ...
  http://www.biomedsearch.com/nih/8-year-single-centre-experience/23315159.html
*  US6477429B1 - Endocardial defibrillation lead with looped cable conductor - Google Patents
A coil electrode is connected to an elongated, flexible, electrically non-conductive lead body and is supplied with electrical ... power for delivering electrical shocks to the heart through a looped cable conductor that extends through the lead body and is ... An implantable endocardial defibrillation lead having a looped cable conductor for conducting at least high voltage ... Thus, a single device implantable in one surgical procedure could provide defibrillation and pacing pulses for heart patients ...
  https://patents.google.com/patent/US6477429B1/en
*  Boston Scientific: Products To Watch In 2014
Subcutaneous-Implantable Cardioverter Defibrillators (S-ICD): Boston Scientific's CRM division acquired Cameron Health in 2012 ... and with it a next generation ICD (known as S-ICD) that does not require a transvenous lead to connect to the heart. The ... Lotus' Transcatheter Aortic Valve device: This device is used to replace impaired heart valves in patients who are too weak for ... We expect sales of this device to help the EP division sustain its mid single-digit sales growth in 2014 as well. ...
  https://www.forbes.com/sites/greatspeculations/2014/02/11/boston-scientific-products-to-watch-in-2014/
*  Veröffentlichungen | Ev. Klinikum Bethel - Ihr Krankenhaus in Bielefeld
Complications leading to surgical revision in implantable cardioverter defibrillator patients: comparison of patients with ... Israel CW, Kruse I, van Mechelen R, Kroes G, Heynen H, Lokhoff N. Results of a Preshaped Lead for Single-Pass VDD/DDD ... Training requirements for transvenous implantation of pacemakers and cardioverter-defibrillators. Thorac Cardiovasc Surg. 2009 ... Single-lead VDD-pacing system incorporating high impedance stimulation: a multicentre study. Europace. 2002 Apr;4(2):129-35. ...
  http://evkb.de/fuer-patienten-und-besucher/behandlung-diagnostik/innere-medizin/kardiologie-nephrologie-und-diabetologie/fachinformationen/veroeffentlichungen.html
*  Patent US7444182 - Method for discriminating between ventricular and supraventricular arrhythmias - Google Patents
The present invention is direction toward a detection architecture for use in implantable cardiac rhythm devices. The detection ... Transvenous implantable cardioverter/defibrillators (transvenous ICDs) have been established as an effective treatment for ... in single or multi lead systems (whether subcutaneous, epicardial or transvenous), these rate deviations may be identified by ... For example, the high rate boundary may be set at 240 bpm for adult patients, whereas for children, the high rate boundary may ...
  http://www.google.com/patents/US7444182?dq=5527183
*  Global Cardiac Monitoring and Cardiac Rhythm Management Devices Market: Size, Trend, Share, Opportunity Analysis, and Forecast,...
ECG, by lead * Single Lead * 3-6 Lead * 12 Lead * Implantable Loop Recorders (ILR) * Cardiac Output Monitoring (COM) Devices * ... Implantable Cardioverter Defibrillators (ICDs) * Transvenous Implantable Cardioverter Defibrillator (T-ICDs) * Dual-Chamber ... The system is MRI labeled; hence, this enables patients implanted with S-ICD system to undergo an MRI scan safely. This has ... Single Lead ECG Market Value, 2014-2016, $million *Figure 8.Cardiac Monitoring and Cardiac Rhythm Management Devices: 3-6 Lead ...
  https://www.giiresearch.com/report/prog511115-global-cardiac-monitoring-cardiac-rhythm.html
*  US5690686A - Atrial defibrillation method - Google Patents
Transvenous defibrillating lead US4375817A (en) * 1979-07-19. 1983-03-08. Medtronic, Inc.. Implantable cardioverter ... In modern implantable cardioverter/defibrillators, the particular therapies are programmed into the device ahead of time by the ... This electrode system employed a single lead with electrodes located in the atrium and pulmonary artery. More recently, the use ... A simple device of this type is believed workable in some patients. However, inclusion of the ability to detect and terminate ...
  https://patents.google.com/patent/US5690686
*  US7027861B2 - Method and apparatus for affecting atrial defibrillation with bi-atrial pacing - Google Patents
... been recognized that a totally transvenous system would be desirable in order to simply the use of implantable defibrillators. ... This electrode system employed a single lead with electrodes located in the atrium and pulmonary artery. ... In many patients, upon successful termination of atrial fibrillation by cardioversion and/or defibrillation, the immediate or ... The lead system includes three leads. A right atrial lead 101 includes an elongated insulative lead body 102, to which a coiled ...
  https://patents.google.com/patent/US7027861
*  Devices in heart failure; diagnosis, detection and disease modification, British Medical Bulletin | 10.1093/bmb/ldx051 |...
Subcutaneous implantable cardioverter defibrillators By avoiding trans-venous leads and the intravascular complications ... has allowed the opportunity to pace the lateral wall of the left ventricle from several points at once using a single lead. ... Outcomes of implantable cardioverter-defibrillator use in patients with comorbidities: results from a combined analysis of 4 ... Subcutaneous implantable cardioverter defibrillators By avoiding trans-venous leads and the intravascular complications ...
  https://www.deepdyve.com/lp/ou_press/devices-in-heart-failure-diagnosis-detection-and-disease-modification-hkQ4OwnM8h
*  Management of the Patient With Implantable Cardioverter-Defibrillator Lead Failure | Circulation
Predictors of complications of endovascular chronic lead extractions from pacemakers and defibrillators: a single operator ... Lead Extraction. Lead extraction in patients with a failed ICD lead should be carefully considered. The Table summarizes the ... Initial experience with a laser sheath to extract chronic transvenous implantable cardioverter-defibrillator leads. Am J ... This may be the appropriate strategy in older patients, patients with multiple comorbidities, or patients for whom lead ...
  http://circ.ahajournals.org/content/123/12/1352
*  Lessons for the Clinical Implant | Springer for Research & Development
Sudden death in patients with implantable cardioverter defibrillators: the importance of post-shock electromechanical ... Comparison of single- and dual-coil active pectoral defibrillation lead systems. J Am Coll Cardiol1998;31:1391-1394PubMedGoogle ... Shukla HH, Flaker GC, Jayam V, Roberts D. High defibrillation thresholds in transve nous biphasic implantable defibrillators: ... Serial defibril lation lead impedance in patients with epicardial and nonthoracotomy lead systems. J Cardiovasc Electrophysiol ...
  https://rd.springer.com/chapter/10.1007/978-0-387-79403-7_19
*  Tips Plus More Tips for Cardiology in 2013 - AAPC Knowledge Center
... and 33249 Insertion or replacement of permanent pacing cardioverter-defibrillator system with transvenous lead(s), single or ... Subcutaneous Implantable. Defibrillators (S-ICD). This year, CPT® adds new Category III codes for S-ICD systems. Shortened ... It's indicated for patients with severe aortic stenosis who are not surgical candidates (determined by a cardiothoracic surgeon ... The generator and one lead are placed subcutaneously. This allows for easier insertion over traditional transvenous insertion ...
  https://www.aapc.com/blog/23034-tips-plus-more-tips-for-cardiology-in-2013/
*  Patent US6445958 - Steerable coronary sinus defibrillation lead - Google Patents
... allowing the lead to be more easily placed within the coronary sinus. The lead comprises an elongated lead body having a ... The distal end of the lead body has a permanent set or bend. A torque tube, extending through a lumen in the lead body from the ... A cable passes through the torque tube from the proximal end of the lead through the anchor block to the distal end of the lead ... proximal end of the lead to an anchor block adjacent the distal end of the lead, can be rotated by a physician to orient the ...
  http://www.google.com.au/patents/US6445958
*  Patente US7610092 - Leadless tissue stimulation systems and methods - Google Patentes
Cardiac pacing and arrhythmia control is accomplished with one or more implantable receiver-stimulators and an external or ... Systems are implanted by testing external or implantable devices at different tissue sites, observing physiologic and device ... Systems including an implantable receiver-stimulator and an implantable controller-transmitter are used for leadless electrical ... "Adverse Events with Transvenous Left Ventricular Pacing in Patients with Sever Heart Failure: Early Experience from a Single ...
  http://www.google.es/patents/US7610092
*  Cardiac Literature, including Myocardial Infarction, arrthymias, tachycardia, and angina sub-cluster 42
Implantable cardioverter defibrillators (ICDs) are increasingly used for the prevention of sudden cardiac death in patients ... A single-coil active fixation lead was introduced via a purse-string suture in the right atrial appendage and the lead tip ... Successful use of a transvenous dual-chamber automatic implantable cardiac defibrillator after a ... ... Implantable cardioverter defibrillator (ICD) implantation is a common approach in patients at high risk of sudden cardiac death ...
  http://www.biomedsearch.com/cluster/1/Cardiac-Literature-including-Myocardial-Infarction-arrthymias-tachycardia-and-angina/sub-42-p14.html
*  Patente US7558631 - Leadless tissue stimulation systems and methods - Google Patentes
Cardiac pacing and arrhythmia control is accomplished with one or more implantable receiver-stimulators and an external system ... Systems including an implantable receiver-stimulator and an external controller-transmitter system are used for leadless acute ... "Adverse Events with Transvenous Left Ventricular Pacing in Patients with Severe Heart Failure: Early Experience from a Single ... Daoud et al., " Implantation Techniques and Chronic Lead Parameters of Biventricular Pacing Dual-chamber Defibrillators," J ...
  http://www.google.es/patents/US7558631
*  Patent US7890173 - Implantable transducer devices - Google Patents
The use of single crystal piezoelectric materials enhance sensitivity. ... "Adverse Events with Transvenous Left Ventricular Pacing in Patients with Severe Heart Failure: Early Experience from a Single ... Daoud et al., "Implantation Techniques and Chronic Lead Parameters of Biventricular Pacing Dual-chamber Defibrillators," J ... "A Comparison of Antiarrhythmic Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near Fatal ...
  http://www.google.ca/patents/US7890173
*  Managing Cardiovascular Implantable Electronic Devices (CIEDs) During Perioperative Care
Expert Consensus Statement on the perioperative management of patients with implantable defibrillators, pacemakers and ... a right ventricular lead, and a coronary sinus lead. In addition, the right ventricular lead is a shocking coil, which is ... The consensus emphasizes that a single recommendation for all CIED patients is not appropriate. It is extremely important that ... Alternative methods of pacing patients intraoperatively include transesophageal pacing, transcutaneous pacing, or transvenous ...
  https://www.apsf.org/article/managing-cardiovascular-implantable-electronic-devices-cieds-during-perioperative-care/
*  Venous Obstruction in Cardiac Rhythm Device Therapy | SpringerLink
Pacemaker and defibrillator lead insertion may cause proximal venous... ... Sadarmin PP, Chelliah RK, Timperley J. Contralateral transvenous left ventricular lead placement of implantable devices with ... Venous access thrombosis detected by transcutaneous vascular ultrasound in patients with single-polyurethane-lead permanent ... Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near ...
  https://link.springer.com/article/10.1007/s11936-018-0664-5
*  where to buy Zeagra in india the Corning
Predictors and mode of detection of transvenous lead malfunction in implantable defibrillators. Nat. Generic Filagra and india. ... The indi a of Bells palsy is higher in preg- where to buy Zeagra in india women and in patients with diabetes mellitus or a ... McKendrick,A. The first step in HR is the coating of the single strand DNA (ssDNA) with molecules of replication protein Wheere ... When associated with aniridia, Wilms Zegara is inida before pa- tients reach age 5 in 80 of cases. 0 ml with the same solution ...
  http://tovopt.ru/buy-erectile-dysfunction-pills/where-to-buy-zeagra-in-india.html
*  Cameron Health - Wikipedia
In the European trial of 55 patients, after 46 patient-years of follow-up, 54 of 55 patients were alive, and the single death ... which they called a Subcutaneous Implantable Defibrillator (S-ICD). Cameron Health's approach avoided implanting transvenous ... According to one estimate, patients with ICDs have a 20 percent chance of lead failure within 10 years, and replacing the leads ... access-date= requires ,url= (help) Meier, Barry (13 May 2010). "Under-Skin Defibrillators Seen Closer to Reality". The New York ...
  https://en.wikipedia.org/wiki/Cameron_Health