*  Mouse CD23 Multiplex Immunoassay Kit (ab221510) | Abcam
Mouse CD23 Multiplex Immunoassay Kit Mplex Immunoassay Kits datasheet (ab221510). Abcam offers quality products including ... Important - Use of the FirePlex Multiplex Immunoassay Kit also requires the purchase of:. - a) Mouse Multiplex Immunoassay Core ... b) Multiplex Immunoassay Protein Standard Mix, such as ab221503.. FirePlex® is a registered trademark in the United States and ... ELISA, Matched Antibody Pairs and Multiplex Immunoassays. Cell and tissue imaging tools. Cellular and biochemical assays. By ...
  http://www.abcam.com/mouse-cd23-multiplex-immunoassay-kit-ab221510.html
*  Analytical and clinical evaluation of an electrochemiluminescence immunoassay for the determination of CA 125 | Clinical...
The Elecsys CA 125 II test is a sandwich immunoassay that is provided for Elecsys immunoassay systems (Boehringer Mannheim GmbH ... and 607 enzyme immunoassays, two microparticle enzyme immunoassays (MEIA 1 on AxSYM® and MEIA 2 on IMx® immunoanalyzers, Abbott ... Multicenter technical and clinical evaluation of a fully automated enzyme immunoassay for CA 125. Clin Chem 1992;38:1466-1471. ... Analytical and clinical evaluation of an electrochemiluminescence immunoassay for the determination of CA 125. Huub E. van ...
  http://clinchem.aaccjnls.org/content/44/12/2530.full
*  Hepatitis C Virus Diagnosis for Clinicians - RNA Testing - Oncquest - Blog
Rapid immunoassay tests use a unique combination of modified HCV antigens conserved across all genotypes. However, some studies ... Enhanced chemiluminescence immunoassay (ECi) a quantitative assay based on chemiluminescent reaction, which is as good as ELISA ... Detection of HCV core-antigen, a protein with highly conserved sequence, by enzyme-immunoassays may be a simpler alternative to ... Anti-HCV antibodies can be detected by rapid immunoassays, enzyme-linked immunosorbent assays (ELISA), or chemiluminescent ...
  http://blog.oncquest.net/hepatitis-c-virus-diagnosis-for-clinicians-rna-testing/
*  Bead-Based Immunoassays<...
These values may vary based on type of a bead-based immunoassay.. ...
  http://www.curiox.com/bead-based-immunoassays/
*  Sensors | Free Full-Text | Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved...
... combined with lateral flow immunoassay (LFIA). The performance of the new developed kit was evaluated in the aspects of ... Shao X-Y, Wang C-R, Xie C-M, Wang X-G, Liang R-L, Xu W-W. Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin ... Shao, X.-Y.; Wang, C.-R.; Xie, C.-M.; Wang, X.-G.; Liang, R.-L.; Xu, W.-W. Rapid and Sensitive Lateral Flow Immunoassay Method ... Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved Immunochromatography. Xiang- ...
  http://www.mdpi.com/1424-8220/17/3/480
*  Used Johnson & Johnson, Vitros EciQ, Immunoassay Analyzer, Enzyme for Sale - 485634568
Check out our extensive catalog of New & Used Johnson & Johnson Vitros EciQ Immunoassay Analyzer, Enzyme devices. More than ... Johnson Vitros EciQ Immunoassay Analyzer, Enzyme for Sale. ... View more Immunoassay Analyzer, Enzyme devices for sale. Vidas ... Immunoassay Analyzer, Enzyme may also be referred to as: Chemiluminescence Immunoassay Analyzer , Luminescent Immunoassay ... Fluorescence Immunoassay Analyzer , CLIA , Analyzer, Immunoassay, Chemiluminescence , Enzyme Immunoassay Analyzer ...
  http://www.medwow.com/used-immunoassay-analyzer-enzyme/johnson-johnson/vitros-eciq/485634568.item
*  New Mass Spectrometric Immunoassay Consumables Enable Large Biomolecule Analysis | Business Wire
New Mass Spectrometric Immunoassay Consumables Enable Large Biomolecule Analysis Proprietary microcolumn technology enhances ... The new Thermo Scientific Mass Spectrometric Immunoassay (MSIA) provides a robust technology designed to purify target proteins ... New Thermo Scientific Mass Spectrometric Immunoassay Consumables Enable Large Biomolecule Analysis (Photo: Business Wire) ... New Thermo Scientific Mass Spectrometric Immunoassay Consumables Enable Large Biomolecule Analysis (Photo: Business Wire) ...
  https://www.businesswire.com/news/home/20140616005427/en/Mass-Spectrometric-Immunoassay-Consumables-Enable-Large-Biomolecule
*  Sensors | Free Full-Text | Performance Improvement of the One-Dot Lateral Flow Immunoassay for Aflatoxin B1 by Using a...
... and accurate lateral flow immunoassay (LFIA) detection method for point-of-care diagnosis. The one-dot LFIA for aflatoxin B1 ( ... Keywords: lateral flow immunoassay; aflatoxin B1; Smartphone; point-of-care lateral flow immunoassay; aflatoxin B1; Smartphone ... Lee S, Kim G, Moon J. Performance Improvement of the One-Dot Lateral Flow Immunoassay for Aflatoxin B1 by Using a Smartphone- ... Performance Improvement of the One-Dot Lateral Flow Immunoassay for Aflatoxin B1 by Using a Smartphone-Based Reading System. ...
  http://www.mdpi.com/1424-8220/13/4/5109
*  Multiplexed immunoassays by flow cytometry for detection of Clenbuterol, Chloramphenicol and sulfadimidine with high...
Hereby we discuss the relevance of an emerging technology, multiplexed competitive immunoassays read by flow cytometry, for the ... These assays are more sensitive than traditional immunoassays , have a high throughput capacity provide a wide analytical ... Multiplexed immunoassays by flow cytometry for detection of Clenbuterol, Chloramphenicol and sulfadimidine with high ... Hereby we discuss the relevance of an emerging technology, multiplexed competitive immunoassays read by flow cytometry, for the ...
  http://www.ct-si.org/publications/proceedings/procs/Cleantech2007/9/1285
*  Mass spectrometric immunoassay - Wikipedia
Mass spectrometric immunoassay (MSIA) is a method that uses antibodies to analyze protein differences in biological samples.[1] ... 1995). "Mass Spectrometric Immunoassay". Analytical Chemistry. 67 (7): 1153-1158. doi:10.1021/ac00103a003. ISSN 0003-2700. PMID ... Retrieved from "https://en.wikipedia.org/w/index.php?title=Mass_spectrometric_immunoassay&oldid=758985804" ...
  https://en.wikipedia.org/wiki/Mass_spectrometric_immunoassay
*  Synovial Fibroblast 3.2: Secretion response of seven primary human synovial fibroblast samples from healthy and rheumatoid...
The immunoassay results are reported as the median fluorescent intensity (MFI) across all beads measured per sample. The number ... 6. Multiplexed bead-based immunoassays used reagents purchased from Bio-Rad and R&D Systems and were analyzed on a Flexmap 3D ... and proteases were measured using a multiplexed bead-based sandwich immunoassay to quantify the secretion response of 7 primary ...
  http://lincs.hms.harvard.edu/db/datasets/20235/
*  Evaluation of a new competitive immunoassay (BioElisa Syphilis...
Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various ... The BioElisa Syphilis, a new competitive enzyme immunoassay (EIA) for Treponema pallidum whole antigen that uses specific human ... Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various ...
  https://www.mysciencework.com/publication/show/evaluation-new-competitive-immunoassay-bioelisa-syphilis-screening-treponema-pallidum-antibodies-various-stages-syphili-7c5d627b
*  Competitive immunoassays at Charles Drew University of Medicine and Science
Competitive immunoassays is an eagle-i resource of type Material analysis service at Charles Drew University of Medicine and ... Competitive immunoassays. eagle-i ID. http://cdrewu.eagle-i.net/i/00000136-312e-bef1-519e-922c80000000 ...
  http://cdrewu.eagle-i.net/i/00000136-312e-bef1-519e-922c80000000
*  Food Safety monitoring by Electrochemical Lateral Flow Immunoassay - Biolan
Biolan is a biotechnology company that works mainly in developing and marketing new biosensors capable of detecting health and agro-food-related molecules.
  http://www.biolanmb.com/rd/food-safety-monitoring-by-electrochemical-lateral-flow-immunoassay-2
*  Federal Contract Opportunity: Lateral Flow Immunoassays, updated Jul 9, 2010
Lateral Flow Immunoassays for the Department of Defense Critical Reagents Program. Base Year and 4 option years. ...
  https://govtribe.com/project/66-lateral-flow-immunoassays
*  rapid immunoassay strip, rapid immunoassay strip wholesale for sale page1 in Tradezz.com
Here you can find the lowest price products about rapid immunoassay strip. We Provide for you about rapid immunoassay strip ... rapid immunoassay strip for sale. Are you looking for rapid immunoassay strip? Tradezz.com not only provides 20001 kinds of ... Detailed The rapid test strip is based on the principle of sandwich immunoassay for determination of HBsAb in serum or plasma. ... rapid immunoassay strip provided by suppliers on our platform are mostly cheap and have good quality. If you have any questions ...
  http://www.tradezz.com/rapid-immunoassay-strip_0/
*  Science Jobs Blog: Senior Lateral Flow Immunoassay Development Scientist | South East UK | to £40K
They seek a lateral flow expert that can guide a team that formulates immunoassays for the detection of drug metabolites in ... You will need to have a relevant scientific degree as well as significant experience of lateral flow immunoassay technology, ... Do you have significant experience in lateral flow immunoassay development gained from a commercial laboratory? Would you like ...
  http://www.seltekjobs.com/2014/07/senior-lateral-flow-immunoassay.html
*  Immunoassay analyser
Immunoassays are chemical tests used to detect or quantify a specific substance, the analyse, in a blood or body fluid sample, ...
  http://www.skf.com/au/industry-solutions/medical-health-care/campaign-sites/lab-automation/applications/immunoassay-analyzer/index.html
*  Immulite Chemiluminescent Immunoassay System
Worldwide, IMMULITE systems have been chosen for various types of immunoassay testing due to their flexible platforms and ... The IMMULITE chemiluminescent immunoassay system is designed for ease of use, reliability, high-performance assays and fully ... Access Immunoassay System. 8. Access 2 Immunoassay System. 9. ADVIA Centaur Immunoassay System. 10. AIA - 600 II Immunoassay ... Immulite 1000 Immunoassay System. 2. Immulite 2000 Advanced Immunoassay System. 3. Immulite 2500 SMS. 4. Immulite PAP. 5. ...
  http://www.bio-medicine.org/medicine-products/Immulite-Chemiluminescent-Immunoassay-System-2921-1/
*  Osteocalcin by Electrochemiluminescent Immunoassay
... ,ARUP Laboratories is a national reference laboratory and a worldwide leader ... Access Immunoassay System. 4. Access 2 Immunoassay System. 5. ADVIA Centaur Immunoassay System. 6. AIA - 600 II Immunoassay ... AIA - 360 Immunoassay Analyzer. 8. AIA - 1800 Immunoassay Analyzer. 9. Immulite Chemiluminescent Immunoassay System. 10. ...
  http://www.bio-medicine.org/medicine-products/Osteocalcin-by-Electrochemiluminescent-Immunoassay-23995-1/
*  Immunoassay Analysis
... accepted the use of immunoassay analysis for the site closure of fuel-contaminated soil. Immunoassay has been used as a ... When immunoassay is used as a screening tool, it will not pick up chemicals that are not suspected of being there. It is not ... Enzyme immunoassay (EIA) test kits are also available for RDX and TNT. It has also been used to screen a site for site closure ... The immunoassay analyses referred to here were conducted in the field to provide real-time data. However, the actual assay ...
  http://www.cpeo.org/techtree/ttdescript/imuass.htm
*  Chromogenic Substrates for Enzyme Immunoassay | SpringerLink
... described according to their kinetics and structure only a few have turned out to be marker enzymes in the enzyme immunoassay ( ... Porstmann B., Porstmann T. (1988) Chromogenic Substrates for Enzyme Immunoassay. In: Ngo T.T. (eds) Nonisotopic Immunoassay. ... 5-tetramethylbenzidine as an Ames test negative chromogen for horse-radish peroxidase in enzyme-immunoassay, J. of Immunoassay ... Cox, C., 1983, NAD labeled immunoassays, Trends in Anal. Chem., 2: 129-131.CrossRefGoogle Scholar ...
  https://link.springer.com/chapter/10.1007/978-1-4684-5466-6_3
*  Patent US5942407 - Light-emitting immunoassay - Google Patents
Migratory detection immunoassay. US4978502 *. Dec 15, 1987. Dec 18, 1990. Dole Associates, Inc.. Immunoassay or diagnostic ... Three Layered Dry Phase Immunoassay Device. A light emitting immunoassay device in accordance with the present invention was ... The immunoassay devices are preferably held or positioned by use of a holding assembly such as a test strip holder known in the ... Multi-spot enzyme immunoassay method. US4818677 *. Dec 3, 1987. Apr 4, 1989. Monoclonal Antibodies, Inc.. Membrane assay using ...
  http://www.google.com/patents/US5942407?dq=6,921,985
*  Patent US4495151 - Element for immunoassay - Google Patents
A thin layer of constant thickness of a liquid specimen for immunoassay is thus receivable between the complementary surfaces. ... Apparatus for performing an immunoassay, comprises in combination a reaction tube closed at its bottom, and in the reaction ... A further object of the present invention is to provide an element for immunoassay which can perform immunoassay with a small ... Solid phase immunoassay with carriers matching the shape of sample wells. US6207463. 20 Oct 1995. 27 Mar 2001. Labsystems Oy. ...
  http://www.google.ca/patents/US4495151