Loading...


*  Ultra Clean High Capacity Combi Filter (oxygen/moisture) for GC and GC/MS | PerkinElmer
The ultra clean high capacity combi filter is perfect for purifying Flame Ionization Detector (FID) fuel gases, removing both ... This high capacity combi filter is perfect for purifying Flame Ionization Detector (FID) fuel gases, removing both moisture and ...
  http://www.perkinelmer.com/product/filter-mstre-hydrocarb-absorb-combi-n9306818
*  Flame Ionization Detection (Monitoring and Testing) Applications on Environmental XPRT
Results for flame ionization detection from leading brands for monitoring and testing. Compare and contact a supplier near you ... C1-C5 hydrocarbons are separated on the analytical column and elute to the flame ionization detector (FID) for analysis. ... Commonly, a single measurement value is obtained through the use of a Flame Ionisation Detection (FID) analyser. The pyrolysis ... The Series 8900 Formaldehyde Analyzer employs a flame ionization detector (FID) as the sensing element. A dual column ...
  https://www.environmental-expert.com/monitoring-testing/flame-ionization-detection/applications
*  Evaluation of Initial Flavor Fade in Fresh Roasted Peanuts using Gas Chromatography-Flame Ionization Detection, Gas...
Evaluation of Initial Flavor Fade in Fresh Roasted Peanuts using Gas Chromatography-Flame Ionization Detection, Gas ...
  https://vtechworks.lib.vt.edu/handle/10919/29127
*  GrokFood - ISOMALT - Joint FAO/WHO Expert Committee on Food Additives (JECFA)
Detector: Flame ionization detector; 360º. Temperature program: 80º (3 min); 10º/min 80º (3 min); 10º/min to 210º; 5º/min to ... Measure the absorbance at 232.0 nm using a nickel hollow-cathode lamp as source of radiation and an air-acetylene flame. ...
  http://www.grokfood.com/jecfa/additive_0492.htm
*  Bid Opportunity: 55i Direct Methane/Non-Methane Hydrocarbon Analyzer with Flame Ionization Detector or equal
55i Direct Methane/Non-Methane Hydrocarbon Analyzer with Flame Ionization Detector or equal. Access many more Instruments and ... 55i Direct Methane/Non-Methane Hydrocarbon Analyzer with Flame Ionization Detector or equal. ...
  http://www.governmentbids.com/government-bid-opportunity-public-3814590-en.jsa
*  Allelopathic effect of Schinus molle essential oils on wheat germination
Gas chromatography-flame ionisation detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS) analyses of the ... Gas chromatography-flame ionisation detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS) analyses of the ...
  https://insights.ovid.com/acta-physiologiae-plantarum/apgp/2010/11/000/allelopathic-effect-schinus-molle-essential-oils/22/00008608
*  NIOSHTIC-2 Publications Search - 00121725 - Personal Atmospheric Gas Sampler With a Critical Orifice. Part 2. System for...
100 torr and carried through two subsystems into a gas chromatograph with a thermal conductivity cell and dual hydrogen flame ... ionization detectors. The first subsystems uses a backflush valve to detect ethane (74840 ... and carried through two subsystems into a gas chromatograph with a thermal conductivity cell and dual hydrogen flame ionization ...
  https://www.cdc.gov/niosh/nioshtic-2/00121725.html
*  Illness Associated with Exposure to Naphthalene in Mothballs -- Indiana
Air samples collected in the apartment on charcoal and analyzed by gas chromatography and flame ionization revealed detectable ...
  https://www.cdc.gov/mmwr/preview/mmwrhtml/00001236.htm
*  Biology-Online • View topic - The Fiber Disease
The extracted sample was analyzed by gas chromatography with flame ionization detection or mass spectrometry. Parameters ...
  http://www.biology-online.org/biology-forum/post-51631.html
*  Analysis of Volatile Compounds in Khadi (an Unrecorded Alcohol Beverage) from Botswana by Gas Chromatography-Flame Ionization...
Gas Chromatography-Flame Ionization Detection. An Agilent 6820 gas chromatograph equipped with polyethylene glycol TPA modified ... Analysis of Volatile Compounds in Khadi (an Unrecorded Alcohol Beverage) from Botswana by Gas Chromatography-Flame Ionization ... and a flame ionization detector was used. A split/splitless injector was used. The injection and detection temperatures were ... was carried out using gas chromatography-flame ionization detection (GC-FID). Ten samples of khadi from two different locations ...
  http://www.scielo.org.za/scielo.php?script=sci_arttext&pid=S0379-43502014000100026&lng=pt&nrm=iso&tlng=en
*  Jet Contact Spring for External Igniter and Auto-Ignite Flame Ionization Detector (FID) | PerkinElmer
Jet Contact Spring for External Igniter and Auto-Ignite Flame Ionization Detector (FID) for the PerkinElmer AutoSystem/ ... Jet Contact Spring for External Igniter and Auto-Ignite Flame Ionization Detector (FID) * ... Jet Contact Spring for External Igniter and Auto-Ignite Flame Ionization Detector (FID) Part Number : N6001204 ... Jet Contact Spring for External Igniter and Auto-Ignite Flame Ionization Detector (FID) for the PerkinElmer AutoSystem/ ...
  http://www.perkinelmer.de/product/contact-fid-jet-n6001204
*  Thermo Scientific TVA-1000B For Sale
... and Photo Ionization Detection (PID) in a single, easy-to-use instrument. ... the shoulder portable vapor analyzer that offers both Flame Ionization Detection (FID) ... the shoulder portable vapor analyzer that offers both Flame Ionization Detection (FID) and Photo Ionization Detection (PID) in ... the shoulder portable vapor analyzer that offers both Flame Ionization Detection (FID) and Photo Ionization Detection (PID) in ...
  http://www.lianamedic.com/analytical-instruments/286-thermo-scientific-tva-1000b-toxic-vapor-analyzer.html
*  Flame ionization detector - Wikipedia
Flame ionization detectors are used very widely in gas chromatography because of a number of advantages. Cost: Flame ionization ... A flame ionization detector (FID) is a scientific instrument that measures analyte in a gas stream. It is frequently used as a ... included a flame ionization detector in its Vapor Fractometer The operation of the FID is based on the detection of ions formed ... The first flame ionization detectors were developed simultaneously and independently in 1957 by McWilliam and Dewar at Imperial ...
  https://en.wikipedia.org/wiki/Flame_ionization_detector
*  Flame Ionization Detector
... A piece of equipment used in gas chromatography that uses a flame to decompose the neutral solute ... Selected flame ionization detector links: © 1997-2006 Healthboard.com. Healthboard.com is a purely informational website, and ...
  http://healthboard.com/Encyclopedia/Biotech/term/flame_ionization_detector.html
*  2.1 Flame Ionization Detection - Page 4 | Geoengineer.org
2.1 Flame Ionization Detection. A flame ionization detector (FID) is a gas detector commonly used to measure methane ... 2.1 Flame Ionization Detection * Advantages and Limitations of Techniques Used to Quantify Methane Emissions From Municipal ... An air sample enters the device, and is combusted by a hydrogen flame. There are two charged electrodes in the device, a ... The flame is produced at the nozzle head, and the collector plate is a tubular electrode above the nozzle head to which the ...
  http://www.geoengineer.org/education/web-based-class-projects/geoenvironmental-engineering-fall-2017/comparing-the-advantages-and-limitations-of-different-techniques-used-to-quantify-methane-emissions-from-municipal-solid-waste-landfills?showall=&start=3
*  Micro-burner Based Flame Ionization Detectors for Micro-scale Gas Chromatographs | SBIR.gov
Micro-burner Based Flame Ionization Detectors for Micro-scale Gas Chromatographs. Printer-friendly version ...
  https://www.sbir.gov/sbirsearch/detail/2775
*  Capillary Chromatography - The Flame Ionization Detector :: Chromatography Online
As the flame ionization detector (FID) is mass sensitive as opposed to concentration sensitive (see book 4 of this series for ... The Flame Ionization Detector. The FID, invented by Harley and Pretorious (6), and separately by McWilliams and Dewer (7), ...
  http://chromatography-online.org/Detectors/Flame-Ionization-Detector/rs_12_18.php
*  Development of headspace-gas chromatography-flame ionization detection procedure to determine volatile fatty acids in zoo...
Article Development of headspace-gas chromatography-flame ionization detection procedure to determine volatile fatty acids in ... Development of headspace-gas chromatography-flame ionization ... Development of headspace-gas chromatography-flame ionization ... Using flame ionization detection LODs were of the order of 0.02- 0.37 mg/L. The analyzed leachate collecting on and close to a ... No comments were found for Development of headspace-gas chromatography-flame ionization detection procedure to determine ...
  https://www.environmental-expert.com/articles/development-of-headspace-gas-chromatography-flame-ionization-detection-procedure-to-determine-volati-251953
*  Development of headspace-gas chromatography-flame ionization detection procedure to determine volatile fatty acids in zoo...
Using flame ionization detection LODs were of the order of 0.02- 0.37 mg/L. The analyzed leachate collecting on and close to a ... Development of headspace-gas chromatography-flame ionization detection procedure to determine volatile fatty acids in zoo ... Development of headspace-gas chromatography-flame ionization detection procedure to determine volatile fatty acids in zoo ...
  https://iwaponline.com/wst/article-abstract/63/12/2873/14570/Development-of-headspace-gas-chromatography-flame
*  9/11, 7/7 & the War on Freedom :: View topic - 1945 Operation Unthinkable: Churchill plan to nuke Moscow
Flames from an explosion light up the Belgrade skyline near a power station after NATO cruise missiles and warplanes attacked ... When Frisch returned to Copenhagen on January 13th, 1939 he performed the experiment in an ionisation chamber in Niels Bohr s ... They calculated that this fission generated a huge 200MeV of kinetic energy and should be observable in an ionisation chamber. ...
  http://www.911forum.org.uk/board/viewtopic.php?t=23686&view=next
*  US6651559B2 - Blanket with variable surface properties for a printing machine - Google Patents
An ionization or flame treatment of the substrate of the blanket both have as their purpose to oxidize the surface of the ... One can in particular point to a chemical treatment, an ionization treatment or a flame treatment. ... by ionization or even by heating, specifically of flame type, this process being conducted in a variable manner in the ...
  https://patents.google.com/patent/US6651559?oq=3691140
*  Organic Vapor Analyzer Rental | Enviro-Equipment, Inc.
Our OVA rental inventory includes photoionization detector rental (PID rental), flame ionization detector rental (FID rental), ...
  https://www.enviroequipment.com/rentals/organic-vapor-analyzer-rental