*  Regional blood volume and peripheral blood flow in postural tachycardia syndrome | Heart and Circulatory Physiology
After a 30-min supine acclimatization period, we measured blood volume by the indocyanine dye dilution technique. Supine ... Dye dilution measurement of blood volume, cardiac output, and total peripheral resistance.. The indocyanine green dye dilution ... Bloomfield DA. Dye Curves: The Theory and Practice of Indicator Dye Dilution. Baltimore, MD: University Park Press, 1974. ... we extrapolated the dye decay curve to the time of dye injection (time = 0), yielding estimated blood volume. Total peripheral ...
  http://ajpheart.physiology.org/content/287/3/H1319.full
*  Table of Contents - September 01, 1961, 9 (5) | Circulation Research
Measurement of Cardiac Output in Man by Dye Dilution Curves Using Simultaneous Ear Oximeter and Whole Blood Cuvette Techniques ... Use of Krypton85 for the Measurement of Cardiac Output by the Single-Injection Indicator-Dilution Technique WILLIAM P. CORNELL ... Collateral Blood Flow to the Myocardium as Determined by the Clearance of Rubidium86 Chloride MATTHEW N. LEVY, ELTAS S. ... Localization of Renin in Juxtaglomerular Cells of Rabbit and Dog Through the Use of the Fluorescent-Antibody Technique ROBERT ...
  http://circres.ahajournals.org/content/9/5
*  Cerebral Hemodynamics After Short- and Long-Term Reduction in Blood Pressure in Mild and Moderate Hypertension | Hypertension
Repeated plasma volume determination with the evans blue dye dilution technique: the method and a computer program. Comput Biol ... Birns J, Markus H, Kalra L. Blood pressure reduction for vascular risk: is there a price to be paid? Stroke. 2005; 36: 1308- ... Cardiac output and blood samples were obtained at the end of HUT followed by returning the subjects back to the supine position ... This technique allowed CBF velocity to be measured precisely at the same acoustic window and at the same angle for repeated ...
  http://hyper.ahajournals.org/content/49/5/1149
*  Clinical review: Practical recommendations on the management of perioperative heart failure in cardiac surgery | Critical Care ...
... while the transpulmonary thermal-dye indicator dilution technique measures intrathoracic blood volume [48], which reflects both ... The evaluation of effective circulating blood volume is more important than the total blood volume. Signs of increased ... Mechanical blood pumps, capable of taking over the full CO of the failing heart, are used today as an established therapy ... ABG = arterial blood gas; ASD, atrial septic defect; ECG, electrocardiogram, RV, right ventricle, SAM, systolic anterior motion ...
  https://ccforum.biomedcentral.com/articles/10.1186/cc8153
*  Extravascular Lung Water and Acute Lung Injury
... intrathoracic blood volume (ITBV) via dye dilution = EVLW. This technique is cumbersome, time consuming, and has not been ... J. C. Bock and F. R. Lewis, "Clinical relevance of lung water measurement with the thermal-dye dilution technique," Journal of ... The intrathoracic blood volume = . The extravascular lung water (EVLW) is equal to the ITTV less the ITBV. ... Early studies used the ratio of the EVLW and the volume of blood within the lungs, that is, the pulmonary blood volume to ...
  https://www.hindawi.com/journals/crp/2012/407035/
*  Patent US6041246 - Single light sensor optical probe for monitoring blood parameters and ... - Google Patents
... based on optical dilution technique, during dialysis, surgeries, intensive care procedure. The effects of blood electrolyte ... based on registration of blood hemoglobin concentration, during long periods of time, such as dialysis session. A method and ... non colinear configuration at a sufficient angle to substantially eliminate the scattering properties of the blood. A primary ... A method and device for the continuous real-time monitoring of relative blood volume change, ...
  http://www.google.co.uk/patents/US6041246
*  Relation between indocyanine green (ICG) plasma disappearance rate and ICG blood clearance in critically ill patients |...
... of ICG does not require absolute ICG blood concentrations and today can be assessed transcutaneously. In thi ... All patients were monitored by the transpulmonary double-indicator (thermo-dye dilution) technique using a thermistor and ... ICG-PDR does reflect ICG blood clearance with sufficient accuracy in critically ill patients and may be used as a surrogate. ... In this study, we analyzed the relation between ICG disappearance rate and ICG blood clearance as parameters of liver function ...
  https://link.springer.com/article/10.1007%2Fs00134-006-0109-6
*  Patent US5024231 - Automated multi-point blood volume analyzer - Google Patents
A tracer is injected into the blood stream of a living being, and a plurality of mixed samples of blood and tracer are removed ... and a time-zero blood portion volume is automatically calculated from the determined blood portion volumes and time intervals. ... A blood portion volume corresponding to each time interval is automatically determined from the tracer level in the mixed ... from the blood stream at a corresponding plurality of measured time intervals subsequent to the injecting step. ...
  http://www.google.ca/patents/US5024231
*  Effect of Heart Rate on Aortic Insufficiency as Measured by a Dye-Dilution Technique | Circulation Research
Measurements of the distance a labeled particle of blood travels back up the descending aorta during a single diastole have ... Effect of Heart Rate on Aortic Insufficiency as Measured by a Dye-Dilution Technique. HOMER R. WARNER, ALAN F. TORONTO ... Effect of Heart Rate on Aortic Insufficiency as Measured by a Dye-Dilution Technique ... Effect of Heart Rate on Aortic Insufficiency as Measured by a Dye-Dilution Technique ...
  http://circres.ahajournals.org/content/9/2/413
*  More POTS Information - Daily Living With Lupus
Plasma volume was measured using 131I labeled human serum albumin using a dye dilution technique, and compared to the predicted ... a negligible change in systolic blood pressure, and a ~5 mmHg increase in diastolic blood pressure. ... Hypovolemia & Blood Volume Regulation. Many patients with POTS have low plasma volumes [27,28], but not all. To determine if ... The blood volume is low in many patients with POTS [5]. This can be objectively assessed with nuclear medicine tests to ...
  https://jenlynn401.wordpress.com/2013/02/23/more-pots-information/
*  Low Blood Volume - mine now proven by Red Cell Mass test | Phoenix Rising ME / CFS Forums
I just got the results from my Red Cell Mass test which was done to measure blood volume It was a fairly straightforward blood ... and 14 control subjects Plasma volume was measured using 131I labeled human serum albumin using a dye dilution technique, and ... If the problem is low blood volume and high blood cell concentration, then more fluid is what's needed, not blood cells. ... In my blood tests it always comes out that my red blood cells are too small. What is that about? Apparently quite common in ME/ ...
  http://forums.phoenixrising.me/index.php?threads/low-blood-volume-mine-now-proven-by-red-cell-mass-test.23636/
*  Patent US7024244 - Estimation of stroke volume cardiac output using an intracardiac pressure sensor - Google Patents
Techniques are described for estimating a rate of blood flow from a heart, such as a stroke volume or a cardiac output, as a ... The dilution of the dye or the temperature and conductivity of the saline is measured downstream. The average volume of blood ... Another existing method for measuring cardiac output is the indicator dilution or thermo-dilution technique, which involves the ... Techniques are described for estimating a rate of blood flow from a heart, such as a stroke volume or a cardiac output, as a ...
  http://www.google.com/patents/US7024244?dq=6,272,646
*  Cardiac function after intermittent antegrade warm blood cardioplegia: contribution of the double-indicator dilution technique....
... evaluation included conventional measurements from a pulmonary artery catheter and data obtained by thermal dye dilution ... Cardiac function after intermittent antegrade warm blood cardioplegia: contribution of the double-indicator dilution technique ... Cardiac function after intermittent antegrade warm blood cardioplegia: contribution of the double-indicator dilution technique ... Home» Cardiac function after intermittent antegrade warm blood cardioplegia: contribution of the double-indicator dilution ...
  https://dial.uclouvain.be/pr/boreal/object/boreal:22577
*  Vascular and extravascular fluid volumes in the Pacific hagfish, Eptatretus stoutii (Lockington)
Dilution curves were obtained. Fluid volume calculations were based upon values extrapolated to "zero" time. The packed blood ... volume was obtained through the simultaneous use of tagged red blood cells and plasma proteins labeled with Evan's blue dye. ... The partitioning of body fluids in the Pacific hagfish was investigated using several experimental techniques. Direct ... Blood cells obtained from donor animals were incubated with L-methionin-methyl-C¹⁴ in a physiological saline for two hours. The ...
  https://ir.library.oregonstate.edu/concern/graduate_thesis_or_dissertations/q524js49s
*  Indocyanine Green-Loaded Nanocarriers as Contrast Agents for NIR Fluorescent Optical Imaging | OMICS International
Fluorescence dilution technique for measurement of cardiac output and circulating blood volume in healthy human subjects. ... 1999) Node Biopsy Guided by Indocyanine Green Dye in Breast Cancer Patients. Jpn J Clin Oncol 29: 604-607 ... Paumgartner G, Probst P, Kraines R, Leevy CM (1970) Kinetics of indocyanine green removal from the blood. Ann N Y Acad Sci 170: ... 1998) Binding properties of indocyanine green in human blood. Invest Ophthalmol Visual Sci 39: 1286-1290. ...
  https://www.omicsonline.org/indocyanine-green-loaded-nanocarriers-as-contrast-agents-for-nir-fluorescent-optical-imaging-2157-7439.1000e122.php?aid=9661
*  Oligohydramnios Imaging: Overview, Workup
Initial studies to objectively measure amniotic fluid volume (AFV) involved dye dilution techniques. The techniques were ... Cervical mucous may cause false-positive results, as can semen and blood. Nitrazine paper turns blue. The amniotic fluid is ... The SDP technique may be a better means of assessing the AFV in twin gestations and in pregnancies at an early gestational age ... Phelan JP, Smith CV, Broussard P, Small M. Amniotic fluid volume assessment with the four-quadrant technique at 36-42 weeks' ...
  https://emedicine.medscape.com/article/405914-overview
*  Physio I Block 4
Q: What is another way to do Indicator Dilution Technique without all the dye?. A: By using cold fluid and measuring ... So return of blood to heart is delayed.. Q: What is rate of blood flow?. A: rate of blood flow = volume of blood flow/cross ... Q: What units are Blood flow and Blood velocity expressed in?. A: Blood flow = cm3/sec. Blood Velocity = cm/sec ... A: Direct Fick Method (based on blood O2 levels) and Dilution Methods (based on injections of green dye). ...
  http://www.caribbeanmedstudent.com/notes/physio-i-block-4/
*  US5458128A - Method and apparatus for noninvasively measuring concentration of a dye in arterial blood - Google Patents
... of the dye in the arterial blood-dye mixture as a function of time, t, from the hemoglobin concentration, Hb; from extinction ... to form the arterial blood-dye mixture; measuring a hemoglobin concentration in a blood sample from the living organism; and ... at wavelength Γ 2 of arterial blood in the artery at a time before a predetermined initial time and of the arterial blood-dye ... coefficients, ε d1 and ε d2 , of the dye at the wavelengths Γ 1 and Γ 2 ; and from the ratio R(0) at the time before the ...
  https://patents.google.com/patent/US5458128
*  DE19738942A1 - Method and apparatus for Injektionszeitpunkt- and injection time determination at thermodilution - Google...
A61B5/0275-Measuring blood flow using tracers, e.g. dye dilution * A61B5/028-Measuring blood flow using tracers, e.g. dye ... The central venous catheter is placed in the usual manner according to the Seldinger technique. Für die Durchführung einer ... A61B5/02-Detecting, measuring or recording pulse, heart rate, blood pressure or blood flow; Combined pulse/heart-rate/blood ... For instance by intrathoracic blood volume. Für die Berechnung dieser Parameter ist die Kenntnis der charakteristischen Zeiten ...
  https://patents.google.com/patent/DE19738942A1/en
*  US4508123A - Thermodilution injectate assembly - Google Patents
In the dye dilution technique, a dye of known concentration is released in the blood stream and is sampled downstream. The ... A61B5/0275-Measuring blood flow using tracers, e.g. dye dilution * A61B5/028-Measuring blood flow using tracers, e.g. dye ... dye dilution and thermal dilution. In both techniques a catheter is inserted into the flow region. ... The thermal dilution technique, first introduced in 1971 by Drs. Swan and Ganz, replaced the dye injection with a bolus of ...
  https://patents.google.com/patent/US4508123
*  US4633881A - Ambulatory ventricular function monitor - Google Patents
A61B5/026-Measuring blood flow * A61B5/0275-Measuring blood flow using tracers, e.g. dye dilution ... Several radiopharmacological techniques are known to monitor ventricular cardiac performance. Contrast angiography, ... A61B5/02-Detecting, measuring or recording pulse, heart rate, blood pressure or blood flow; Combined pulse/heart-rate/blood ... Blood glucose tracking apparatus and methods US20100100580A1 (en) * 2001-04-02. 2010-04-22. Abbott Diabetes Care Inc.. Blood ...
  https://patents.google.com/patent/US4633881
*  BME210 MeasuringCO - Copy - BME 210 Biomedical Computer Simulation Methods Measuring Cardiac Output I II Introduction...
Technique of Dye Dilution IV. Formula for Cardiac Output V. Correction for Recirculation VI. Injection and Sample Sites VII. ... BME 210 Spring 2009 Measuring Cardiac Output 2 Measuring Cardiac Output I. Introduction The volume of blood pumped by the heart ... techniques for measuring cardiac output and will study in detail one class of techniques known as indicator dilution techniques ... we will introduce details of the technique of dye-dilution for measuring cardiac output. We will then study the basic ...
  https://www.coursehero.com/file/5950104/BME210-MeasuringCO-Copy/
*  Glucose Metabolism in Abdominally Obese Hypertensive and Normotensive Subjects | Hypertension
Measurement of skeletal muscle blood flow in humans: plethysmographic, bolus and continuous infusion techniques. Am J Cardiol. ... Impedance cardiography has been compared with both thermodilution and indocyanine green dye dilution27 with good agreement ... HR indicates heart rate; MBP, mean blood pressure; CO, cardiac output; and CBF, calf blood flow. • indicates upper-body obese ... Calf blood flow also increased significantly in both normotensive groups, from 2.1±0.3 to 2.5±0.3 mL/dL per minute in the lean ...
  http://hyper.ahajournals.org/content/26/1/186
*  US3614955A - Standby defibrillator and method of operation - Google Patents
A61B5/026-Measuring blood flow * A61B5/0275-Measuring blood flow using tracers, e.g. dye dilution ... using combinations of techniques provided for in this group with electrocardiography or electroauscultation; Heart catheters ... A61B5/02-Detecting, measuring or recording pulse, heart rate, blood pressure or blood flow; Combined pulse/heart-rate/blood ... A61B5/02-Detecting, measuring or recording pulse, heart rate, blood pressure or blood flow; Combined pulse/heart-rate/blood ...
  https://patents.google.com/patent/US3614955
*  Blood, I Presume?
Students determine the sensitivity of the Kastle-Meyer test: Have students make a serial dilution of bovine blood by setting up ... These can be created using red food dye and/or marker, lipstick, cranberry juice, or any other substance that creates a red ... Irrespective of which technique they use, students must include a control group. Also, if the same scissor and tweezers is used ... Bovine blood; blood cards (filter paper pre-stained with bovine blood); test tubes; eye droppers; scissors; tweezers; cotton ...
  http://scienceteacherprogram.org/biology/SGallagher09.html