*  Letter: Metal sensitivity in patients with joint prosthesis. | The BMJ
Letter: Metal sensitivity in patients with joint prosthesis. Br Med J 1975; 4 :647 ... Letter: Metal sensitivity in patients with joint prosthesis.. Br Med J 1975; 4 doi: https://doi.org/10.1136/bmj.4.5997.647 ( ...
  https://www.bmj.com/content/4/5997/647.1
*  Hypersensitivity to Hip and Knee Implants | SpringerLink
... the potential for metal allergy with the new metal-on-metal joint prostheses. Br J Dermatol. 2003;148:1089-93.PubMedCrossRef ... Metal sensitivity causing loosened joint prostheses. Ann Rheum Dis. 1980;39(5):476.PubMedPubMedCentralCrossRefGoogle Scholar ... Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement. J Bone Joint Surg (Br ... Rejection of metal to metal prosthesis and skin sensitivity to cobalt. Contact Dermatitis. 1976;2(2):65-7.PubMedCrossRefGoogle ...
  https://link.springer.com/chapter/10.1007%2F978-3-319-58503-1_19
*  Anxiety and Reward Interaction and Prediction of Outcomes in Anorexia Nervosa - Full Text View - ClinicalTrials.gov
... metal fragments or foreign bodies, metal prostheses, joints, rods or plates) ... metal fragments or foreign bodies, metal prostheses, joints, rods or plates) ... ferromagnetic metal implantations or devices (electronic implants or devices, infusion pumps, aneurysm clips, ... ferromagnetic metal implantations or devices (electronic implants or devices, infusion pumps, aneurysm clips, ...
  https://clinicaltrials.gov/ct2/show/NCT02948452?recrs=abc&cond=%22Anorexia+Nervosa%22&rank=30&sel_rss=new14
*  Federal Register :: Medical Devices; Draft Guidance; Class II Special Controls Guidance Document: Hip Joint Metal...
Hip Joint Metal/Polymer Constrained Cemented or Uncemented Prosthesis.'' This draft guidance document was developed as a ... Hip Joint Metal/Polymer Constrained Cemented or Uncemented Prosthesis; Availability. A Notice by the Food and Drug ... Hip Joint Metal/Polymer Constrained Cemented or Uncemented Prosthesis" via your fax machine, call the CDRH Facts-On-Demand ... Hip Joint Metal/Polymer Constrained Cemented or Uncemented Prosthesis." This draft guidance document was developed as a special ...
  https://www.federalregister.gov/documents/2001/09/06/01-22287/medical-devices-draft-guidance-class-ii-special-controls-guidance-document-hip-joint-metalpolymer
*  Resurfacing hip replacement failure | Radiology Case | Radiopaedia.org
Metal on metal prostheses were reintroduced for total hip replacements mainly for younger people because they were associated ... FINDINGS:Previous left hip joint metal on metal prosthesis (Birmingham). There is asymmetry of the femoral head component ... Metal on metal prostheses were reintroduced for total hip replacements mainly for younger people because they were associated ... metal on metal pseudotumour) that is thought to be due to soft tissue reaction to nanometer sized metal particles1. ...
  https://radiopaedia.org/cases/resurfacing-hip-replacement-failure
*  What are the common complications from hip replacement surgery? | Reference.com
In joint prostheses that involve metal-on-metal contact, certain other complications can arise, and wear and tear may make a ... In some prostheses, metal cup liners hold the metal ball. In those cases, metal ions sometimes get into the bloodstream and ... The majority of artificial hip joints feature a ceramic or polished metal ball that sits in a cup liner made from hard plastic ... A: Hip replacement surgery may result in blood clots in leg veins, infection, hip joint fracture and a difference in the ...
  https://www.reference.com/health/common-complications-hip-replacement-surgery-934697f6cac1c7b9
*  ACMT - ACMT Net
Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum ...
  https://www.acmt.net/cgi/page.cgi/zine_service.html/The_ACMT_Connection/Highlights_from_JMT_s_December_2017_Issue_
*  Occupational Skin Disease - Page 3 - CREOD
2009 Mar-Apr;20(2):E4-9. ABSTRACT: A rare case of contact allergic dermatitis from metal knee joint prostheses is presented. ... The low incidence of allergic contact dermatitis from metal prostheses is surprising, especially given the frequency of metal ... An interesting case of joint prosthesis allergy.. Beecker J, Gordon J, Pratt M. Dermatitis. ...
  http://creod.on.ca/topics/occupational-skin-disease/page/3/
*  Patent US8057478 - Unicondylar knee instrument system - Google Patents
Metal tibial anchoring part for a partial knee joint prosthesis. US5037439. Apr 11, 1989. Aug 6, 1991. Albrektsson Bjoern. Knee ... Knee joint prostheses. US20030130665. Sep 10, 2002. Jul 10, 2003. Pinczewski Leo Arieh. Method of arthroplastly on a knee joint ... Knee joint prosthesis. US5628749. Jun 7, 1995. May 13, 1997. Smith & Nephew Richards Inc.. Tibial resection instrumentation and ... Tibial knee joint prosthesis with removable articulating surface insert. US4719908. Aug 15, 1986. Jan 19, 1988. Osteonics Corp. ...
  http://www.google.com/patents/US8057478?dq=5435091
*  Patent US5344458 - Arthroplasty component - Google Patents
Metal tibial anchoring part for a partial knee joint prosthesis. US5064439 *. Jan 20, 1987. Nov 12, 1991. Richards Medical ... The present invention is applicable to joints other than the glenohumeral joint. Other joints which have bones which may be ... The procedure may require use of artificial joint components to replace natural joint portions. Some natural Joint portions are ... Metal anchoring part for a knee joint endoprosthesis. US4963152 *. Jul 17, 1989. Oct 16, 1990. Intermedics Orthopedics, Inc.. ...
  http://www.google.com/patents/US5344458?dq=5,884,272
*  Neck-Preserving Femoral Stems | SpringerLink
Metal hip joint: a new self-locking vitallium prosthesis. S Med J 1952;45(11):1015-19CrossRefGoogle Scholar ... Two and a half years' experience with a vitallium intramedullary hip prosthesis. J Bone Joint Surg Am 1954;36-A(3):489-502 ... The medium-term results of a cemented Freeman femoral neck-retaining prosthesis. J Bone Joint Surg [Br] 2000;82-B:188-91 ... Freeman MAR, Plante-Bordeneuve P. Early migration and late aseptic failure of proximal femoral prosthesis. J Bone Joint Surg [ ...
  https://link.springer.com/article/10.1007/s11420-012-9302-z
*  Joint Degeneration and Arthritis: Incidence, Understanding and Approaches to Reversing Joint Degeneration | Acupuncture...
While we have rejected metal-on-metal joint prostheses, we have not restored public trust. A more comprehensive and holistic ... They were not adequately informed of the long-term outcomes with joint prostheses, though, as there is a relatively short ... The failures of metal-on-metal hip replacements will generate many billions of dollars in added healthcare costs, time off work ... Joint degeneration is usually referred to as osteoarthritis, but this term does not apply to all degenerative joint conditions ...
  http://www.acupunctureintegrated.com/articles/joint-degeneration-and-arthritis
*  US5314493A - Femoral hip joint prosthesis - Google Patents
A femoral hip joint prosthesis includes a metal component having a double tapered stem and a preapplied cement mantle with an ... The metal component of the femoral hip joint prosthesis P of the present invention is formed of high-strength forged Co-Cr-Mo ... Endo-prosthesis, a femoral head prosthesis and an acetabulum prosthesis US6695884B1 (en) 2004-02-24. Joint implant having ... US5314493A - Femoral hip joint prosthesis - Google Patents. Femoral hip joint prosthesis Download PDF Info. Publication number ...
  https://patents.google.com/patent/US5314493
*  Electro Interstitial Scan (EIS) and Electrical Dispersion Analysis (EDA) - VitalScan
With extremities or joints carrying prostheses or metal pins. * Pregnant women cannot be exposed to this device, as possible ...
  http://www.vitalscan.jp/dtr_bioscan_eis.htm
*  Letter to the Editor
By accepted definition, some surgical site infections such as those with implants (sternal wires, joint prostheses, other metal ...
  http://www.infectioncontroltoday.com/news/2000/04/letter-to-the-editor.aspx
*  DOT: Wiss. Literatur
"Ceramized Articulating Surfaces of Metal-Metal Hip Joint Prosthesis". H.-G. Neumann , A. Baumann, G. Wanke, K.J. Hamelynck, M. ... Bioceramics in Hip Joint Replacement, Proceedings 5th. International CeramTec Symposium, Stuttgart 2000 (ed. G. Willmann, K. ...
  http://www.dot-coating.de/index.php/unternehmen/forschung-entwicklung/wiss-literatur
*  Hip resurfacing and pseudotumour. - Centre for Osteoarthritis Pathogenesis
Metal on metal hip resurfacing has been used widely over the last ten years but there has been recent concern about destructive ... Joint Diseases, Metal-on-Metal Joint Prostheses, Prosthesis Design, Prosthesis Failure ... Metal on metal hip resurfacing has been used widely over the last ten years but there has been recent concern about destructive ... Arthroplasty, Replacement, Hip, Granuloma, Plasma Cell, Hip Prosthesis, Humans, ...
  https://oacentre.kennedy.ox.ac.uk/publications/155143
*  Published Abstracts
Ho J, Wax P, Leikin JB, Archer JRH, Wood DM, Dargan PI, Brent J. Metal-on-metal hip joint prostheses: a retrospective case ... Characteristics of Patients Presenting to a Medical Toxicologist for Exposure to Heavy Metals. J Med Toxicol 2014,10;79. Click ...
  https://www.acmt.net/Published_Abstracts.html
*  Patent US5443523 - Femoral stem cement mantle - Google Patents
A preformed cement mantle having elongated interstices may be preapplied to a fernoral stem prosthesis. ... interstices configured to enhance the ability of additional bone cement to fully encapsulate those portions of the metal ... A femoral stem prosthesis with a preapplied cement mantle having a design with elongated ... 1, when applied to the metal hip joint prosthesis, the preapplied cement mantle 30 extends from an area slightly spaced from ...
  http://www.google.com/patents/US5443523?dq=6760745
*  About - Mayo Clinic
... shinbone and kneecap and replacing it with an artificial joint (prosthesis) made of metal alloys, high-grade plastics and ... Daily use wears on even the strongest metal and plastic parts. Joint failure risk is higher if you stress the joint with high- ... After preparing the joint surfaces, the surgeon attaches the pieces of the artificial joint. Before closing the incision, he or ... Your knee will be in a bent position to expose all surfaces of the joint. After making an incision about 6 to 10 inches (15 to ...
  https://www.mayoclinic.org/tests-procedures/knee-replacement/about/pac-20385276?p=1
*  Patent US7497874 - Knee joint prosthesis - Google Patents
A modular knee prosthesis includes a femoral stem having a proximal end portion. A femoral component includes a first ... Assembly of a ceramic head on a metal rod for a hip prosthesis. ... Bone prosthesis assembly for a knee joint. US4770658. 1 May ... a knee joint prosthesis according to other features is generally identified at reference 400. The knee joint prosthesis 400 ... a knee joint prosthesis according to other features is generally identified at reference 500. The knee joint prosthesis 500 ...
  http://www.google.ca/patents/US7497874
*  US5639280A - Constraining ring for a hip cup - Google Patents
... preferably formed from fiber metal, and a compression molded polyethylene component defining an articulating surface at its ... The hip cup of this invention includes a porous metal outer shell, ... Acetabulum prosthesis of metal for hip joint. DE4220462C1 (en) * 1992-06-23. 1993-11-18. S & G Implants Gmbh. Hip-joint ... Joint prosthesis US4955919A (en) * 1983-05-06. 1990-09-11. Pappas Michael J. Multi-component joint prosthesis with increased ...
  https://patents.google.com/patent/US5639280A/en
*  Physical therapy role in joint replacements - Sampson Independent
In this procedure, an orthopedic surgeon replaces the original joint with a prosthesis (artificial joint) made of metal or high ... HomeFeaturesHealthPhysical therapy role in joint replacements. .neFileBlock{ display:none; } Physical therapy role in joint ... Do you find that daily activities have become painful due to joint pain? Arthritis, injuries and overuse of muscles and joints ... The individual will also be advised about which positions to avoid, in an effort to protect the joint while it is healing. ...
  https://www.clintonnc.com/features/health/1577/physical-therapy-role-in-joint-replacements
*  Patent US4562598 - Joint prosthesis - Google Patents
A joint prosthesis for insertion in a bone cavity comprises an adapter; a hollow, flexible prepreg member of hardenable ... Method of making a metal bone implant. US4888022 *. 24 Nov 1987. 19 Dec 1989. Huebsch Donald L. Endoprosthesis. ... 1. A joint prosthesis kit comprising. (a) a joint prosthesis for insertion in an intramedullary cavity; said joint prosthesis ... 7. A joint prosthesis kit as defined in claim 1, wherein said nipple being formed to support thereon a joint bearing element. ...
  http://www.google.co.uk/patents/US4562598