Passage of dextran magnetite nanoparticles through the subcupular space of the pigeon. (25/347)

We examined the permeability of the subcupular space for endolymph flow in the pigeon. A new technique was developed in which nanoparticles consisting of dextran magnetite were attracted by use of a magnet, instead of injecting a dye solution. The method was revealed to prevent an excess pressure application by the injection of dye solution. The Berlin blue color resulting from the dextran magnetite nanoparticles was found mainly within the subcupular space contacting with the sensory hairs. Further formation of the Berlin blue was found within the sensory cells. The result supports the idea that the fluid passes through the subcupular space.  (+info)

Rapid breakdown of microvascular barriers and subsequent hemorrhagic transformation after delayed recombinant tissue plasminogen activator treatment in a rat embolic stroke model. (26/347)

BACKGROUND AND PURPOSE: Thrombolytic therapy with recombinant tissue plasminogen activator (rtPA) after stroke increases risk of hemorrhagic transformation, particularly in areas with blood-brain barrier leakage. Our aim was to characterize acute effects of rtPA administration on the integrity of microvascular barriers. METHODS: Stroke was induced in spontaneously hypertensive rats by unilateral embolic middle cerebral artery occlusion. Six hours after stroke, rtPA was intravenously administered (n=10). Controls received saline (n=4). Extravasation of the large-diameter contrast agent monocrystalline iron oxide nanocolloid (MION) was assessed with susceptibility contrast-enhanced MRI during rtPA injection. In addition, we performed perfusion MRI and diffusion-weighted MRI. After MRI, 2 hours after rtPA treatment, intracerebral hemorrhage was quantified with a spectrophotometric hemoglobin assay. RESULTS: Late rtPA treatment resulted in increased hemorrhage volume (8.4+/-1.7 versus 2.9+/-0.9 micro L in controls; P<0.05). In MION-injected animals, during rtPA administration, transverse relaxation rate change (DeltaR2*) increased from 12.4+/-6.0 to 31.6+/-19.2 s(-1) (P<0.05) in areas with subsequent hemorrhage. Significant DeltaR2* changes were absent in nonhemorrhagic areas, in animals without injected MION, and in saline-treated animals. Thrombolytic therapy did not improve perfusion in regions with hemorrhagic transformation (cerebral blood flow index was 22.8+/-19.7% [of contralateral] at 0.5 hours before and 22.4+/-18.0% at 1 hour after rtPA administration). CONCLUSIONS: The DeltaR2* changes during rtPA delivery in MION-injected animals indicate extravasation of MION, which reflects increased permeability of the blood-brain barrier. This implies that late rtPA treatment rapidly aggravates early ischemia-induced damage to microvascular barriers, thereby enhancing hemorrhagic transformation.  (+info)

Magnetite-based magnetoreception in birds: the effect of a biasing field and a pulse on migratory behavior. (27/347)

To test the hypothesis that single domain magnetite is involved in magnetoreception, we treated Australian silvereyes Zosterops l. lateralis with a strong, brief pulse designed to alter the magnetization of single domain particles. This pulse was administered in the presence of a 1 mT biasing field, either parallel to the direction of the biasing field (PAR group) or antiparallel (ANTI group). In the case of magnetoreceptors based on freely moving single domain particles, the PAR treatment should have little effect, whereas the ANTI treatment should cause remagnetization of the magnetite particles involved in a receptor and could produce a maximum change in that receptor's output for some receptor configurations. Migratory orientation was used as a criterion to assess the effect on the receptor. Before treatment, both groups preferred their normal northerly migratory direction. Exposure to the biasing field alone did not affect their behavior. Treatment with the pulse in the presence of the biasing field caused both the PAR and the ANTI birds to show an axial preference for the east-west axis, with no difference between the two groups. Although these results are in accordance with magnetite-based magnetoreceptors playing a role in migratory orientation, they do not support the hypothesis that single domains in polarity-sensitive receptors are free to move through all solid angles. Possible interpretations, including other arrangements of single domains and superparamagnetic crystals, are discussed.  (+info)

'Fixed-axis' magnetic orientation by an amphibian: non-shoreward-directed compass orientation, misdirected homing or positioning a magnetite-based map detector in a consistent alignment relative to the magnetic field? (28/347)

Experiments were carried out to investigate the earlier prediction that prolonged exposure to long-wavelength (>500 nm) light would eliminate homing orientation by male Eastern red-spotted newts Notophthalmus viridescens. As in previous experiments, controls held in outdoor tanks under natural lighting conditions and tested in a visually uniform indoor arena under full-spectrum light were homeward oriented. As predicted, however, newts held under long-wavelength light and tested under either full-spectrum or long-wavelength light (>500 nm) failed to show consistent homeward orientation. The newts also did not orient with respect to the shore directions in the outdoor tanks in which they were held prior to testing. Unexpectedly, however, the newts exhibited bimodal orientation along a more-or-less 'fixed' north-northeast-south-southwest magnetic axis. The orientation exhibited by newts tested under full-spectrum light was indistinguishable from that of newts tested under long-wavelength light, although these two wavelength conditions have previously been shown to differentially affect both shoreward compass orientation and homing orientation. To investigate the possibility that the 'fixed-axis' response of the newts was mediated by a magnetoreception mechanism involving single-domain particles of magnetite, natural remanent magnetism (NRM) was measured from a subset of the newts. The distribution of NRM alignments with respect to the head-body axis of the newts was indistinguishable from random. Furthermore, there was no consistent relationship between the NRM of individual newts and their directional response in the overall sample. However, under full-spectrum, but not long-wavelength, light, the alignment of the NRM when the newts reached the 20 cm radius criterion circle in the indoor testing arena (estimated by adding the NRM alignment measured from each newt to its magnetic bearing) was non-randomly distributed. These findings are consistent with the earlier suggestion that homing newts use the light-dependent magnetic compass to align a magnetite-based 'map detector' when obtaining the precise measurements necessary to derive map information from the magnetic field. However, aligning the putative map detector does not explain the fixed-axis response of newts tested under long-wavelength light. Preliminary evidence suggests that, in the absence of reliable directional information from the magnetic compass (caused by the 90 degrees rotation of the response of the magnetic compass under long-wavelength light), newts may resort to a systematic sampling strategy to identify alignment(s) of the map detector that yields reliable magnetic field measurements.  (+info)

Iron particle labeling of haematopoietic progenitor cells: an in vitro study. (29/347)

We present a method for labeling bone marrow haematopoietic progenitor cells with iron particles. Labeling was assessed by magnetic resonance imaging and electron microscopy. Labeling with iron particles could allow the following by imaging techniques of haematopoietic cells in physiologic and pathologic conditions such as the engraftment of haematopoietic progenitor cells or the migration of myelomonocytic cells in inflammatory diseases.  (+info)

T1-weighted magnetic resonance imaging sequence appropriate for the evaluation of the longitudinal relaxation effect of superparamagnetic iron oxide: a phantom study. (30/347)

The goal of this study was to determine a T1-weighted magnetic resonance (MR) imaging sequence appropriate for evaluating the longitudinal relaxation effect of superparamagnetic iron oxide (ferumoxides) in a phantom study. An agarose phantom that included various concentrations of ferumoxides (0 - 0.5 mmol/l in 0.05 mmol/l increments) was examined for six types of T1-weighted imaging sequences using a 1.5-T MR unit. Three-dimensional (3D) fast spoiled gradient-echo (SPGR) imaging with a short echo time showed a strong linear correlation between the concentration of ferumoxides and the enhancement ratio. Two-dimensional (2D) fast SPGR imaging showed a high signal-to-noise ratio of the phantom even at low ferumoxides concentrations. These results suggest that 3D fast SPGR imaging is an appropriate technique for the evaluation of the longitudinal relaxation effect of ferumoxides, and that 2D fast SPGR imaging can be useful for evaluating the longitudinal relaxation effect at lower ferumoxides concentrations.  (+info)

Detection of small hypervascular hepatocellular carcinomas in cirrhotic patients: comparison of superparamagnetic iron oxide-enhanced MR imaging with dual-phase spiral CT. (31/347)

OBJECTIVE: To compare the performance of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) maging at 1.5T and dual-phase spiral computed tomography (CT) for the depiction of small hypervascular hepatocellular carcinomas (HCCs). MATERIALS AND METHODS: Forty-three patients with 70 small nodular HCCs (5-20 mm; mean, 13.7 mm) were examined. Diagnosis was based on the results of surgical biopsy in 22 patients and by the combined assessment of MR imaging, lipiodol CT, alpha feto-protein levels, and angiographic findings in 21. MR imaging consisted of respiratory-triggered turbo spin-echo T2-weighted imaging, T1-weighted fast low-angle shot, and T2* -weighted fast imaging with steady-state precession imaging before and after SPIO enhancement. CT imaging was performed with 5-mm collimation and 1:1.4 pitch, and began 30 and 65 secs after the injection of 150 mL of contrast medium at a rate of 3 mL/sec. Two blinded observers reviewed all images independently on a segment-by-segment basis. Diagnostic accuracy was evaluated using receiver operating characteristics(ROC) analysis. RESULTS: The mean areas (Az) under the ROC curves were 0.85 for SPIOenhanced MR imaging and 0.79 for dual-phase spiral CT (p <.05). The mean sensitivity of SPIO-enhanced MR imaging was significantly higher than that of CT (p <.05), i.e. 70.6% for MR imaging and 58.1% for CT. MR imaging had higher false-positive rates than dual-phase spiral CT, but the difference was not statistically significant (3.7% vs 3.3%) (p >.05). CONCLUSION: SPIO-enhanced MR imaging is more sensitive than dual-phase spiral CT for the depiction of small hypervascular hepatocellular carcinomas.  (+info)

Characterization of focal liver lesions with superparamagnetic iron oxide-enhanced MR imaging: value of distributional phase T1-weighted imaging. (32/347)

OBJECTIVE: To determine the potential value of distributional-phase T1-weighted ferumoxides-enhanced magnetic resonance (MR) imaging for tissue characterization of focal liver lesions. MATERIALS AND METHODS: Ferumoxides-enhanced MR imaging was performed using a 1.5-T system in 46 patients referred for evaluation of known or suspected hepatic malignancies. Seventy-three focal liver lesions (30 hepatocellular carcinomas (HCC), 12 metastases, 15 cysts, 13 hemangiomas, and three cholangiocarcinomas) were evaluated. MR imaging included T1-weighted double-echo gradient-echo (TR/TE: 150/4.2 and 2.1 msec), T2*-weighted gradient-echo (TR/TE: 180/12 msec), and T2-weighted turbo spin-echo MR imaging at 1.5 T before and after intravenous administration of ferumoxides (15 mmol/kg body weight). Postcontrast T1-weighted imaging was performed within eight minutes of infusion of the contrast medium (distributional phase). Both qualitative and quantitative analysis was performed. RESULTS: During the distributional phase after infusion of ferumoxides, unique enhancement patterns of focal liver lesions were observed for hemangiomas, metastases, and hepatocellular carcinomas. On T1-weighted GRE images obtained during the distributional phase, hemangiomas showed a typical positive enhancement pattern of increased signal; metastases showed ring enhancement; and hepatocellar carcinomas showed slight enhancement. Quantitatively, the signal-to-noise ratio of hemangiomas was much higher than that of other tumors (p <.05) and was similar to that of intrahepatic vessels. This finding permitted more effective differentiation between hemangiomas and other malignant tumors. CONCLUSION: T1-weighted double-echo FLASH images obtained soon after the infusion of ferumoxides, show characteristic enhancement patterns and improved the differentiation of focal liver lesions.  (+info)