Left ventricular remodeling and improvement in diastolic function after balloon aortic valvuloplasty for congenital aortic stenosis. (1/32)

 (+info)

Hypoplastic right-heart syndrome presenting as multiple miscarriages. (2/32)

Reversible causes of miscarriage are many, but they affect only 1% of women who are trying to conceive. Herein, we describe the case of a 23-year-old woman who presented for evaluation of repeated miscarriages and was found to have hypoxemia and erythrocytosis. Further evaluation revealed hypoplastic right-heart syndrome with an intracardiac shunt. She underwent hybrid repair with pulmonary valve balloon valvuloplasty, followed by surgery to perform atrial septal defect closure and a Glenn anastomosis. The erythrocytosis and hypoxemia resolved, and she was able to conceive and deliver a healthy baby at term 2 years later. This is a unique case of a rare congenital heart defect that went unnoticed until adulthood, when attempts at pregnancy failed because of the associated hypoxemia. Timely and appropriate treatment led to a successful pregnancy after repeated miscarriages. This case exemplifies the need for a comprehensive medical evaluation of every woman with a history of multiple miscarriages to determine whether a reversible cause exists.  (+info)

Role of echocardiography in percutaneous mitral valve interventions. (3/32)

 (+info)

Exercise capacity and ventricular function in patients treated for isolated pulmonary valve stenosis or tetralogy of Fallot. (4/32)

 (+info)

Protective effects of indomethacin and dexamethasone in a goat model with intrauterine balloon aortic valvuloplasty. (5/32)

 (+info)

Echocardiography in transcatheter aortic valve implantation and mitral valve clip. (6/32)

Transcatheter aortic valve implantation and transcatheter mitral valve repair (MitraClip) procedures have been performed worldwide. In this paper, we review the use of two-dimensional and three-dimensional transesophageal echo for guiding transcatheter aortic valve replacement and mitral valve repair.  (+info)

Effect of percutaneous mitral balloon valvuloplasty on left atrial appendage function: transesophageal echo study. (7/32)

 (+info)

The accuracy of three-dimensional echocardiography with multiplanar reformatting in the assessment of the aortic valve annulus prior to percutaneous balloon aortic valvuloplasty in congenital heart disease. (8/32)

OBJECTIVE: To review the use of three-dimensional echocardiography (3DE) with multiplanar reformatting (MPR) in children with congenital aortic stensosis undergoing percutaneous balloon aortic valvuloplasty to assess its accuracy in measuring the aortic valve annulus and any influence it may have on balloon sizing. METHODS: All percutaneous aortic balloon valvuloplasties performed from 01/01/2009 to 01/09/2011 were included in the study. All imaging performed for the procedure to determine the size of the aortic valve annulus and aid in balloon sizing was reviewed. The maximum diameter of the aortic valve annulus using two-dimensional echocardiography (2DE), 3DE with MPR, and angiography was recorded. The balloon size used in the procedure was recorded and the balloon to annulus ratio was calculated. RESULTS: A total of 27 procedures were included in the study. Age varied from 1 day to 156 months (mean age, 53 months) and weight from 2.8-58 kg (mean weight, 18.6 kg). Fourteen patients had 3DE with MPR available for analysis. The 3DE with MPR measurement (13.36 +/- 5.4 mm) was not different from angiography (13.54 +/- 6.4 mm; P=.803).The 2DE measurement was significantly different from angiography (11.72 +/- 5 mm; P<.005). The balloon to annulus ratio based on angiographic measurements did not differ significantly between the patients with 3DE MPR and those without (0.94 +/- 0.095 vs 0.91 +/- 0.1; P=.468). CONCLUSION: 3DE with MPR allows a more accurate assessment of the aortic valve annulus compared to 2DE, which may reduce the tendency to undersize balloon choice. 3DE with MPR did not significantly affect our balloon choice, which was largely based on angiographic measurements.  (+info)