Endovascular stent graft repair of aortopulmonary fistula. (25/18686)

Two patients who had aortopulmonary fistula of postoperative origin with hemoptysis underwent successful repair by means of an endovascular stent graft procedure. One patient had undergone repeated thoracotomies two times, and the other one time to repair anastomotic aneurysms of the descending aorta after surgery for Takayasu's arteritis. A self-expanding stainless steel stent covered with a Dacron graft was inserted into the lesion through the external iliac or femoral artery. The patients recovered well, with no signs of infection or recurrent hemoptysis 8 months after the procedure. Endovascular stent grafting may be a therapeutic option for treating patients with aortopulmonary fistula.  (+info)

Qualitative and semiquantitative polymerase chain reaction testing for cytomegalovirus DNA in serum allows prediction of CMV related disease in liver transplant recipients. (26/18686)

AIM: To identify cytomegalovirus (CMV) infection in liver transplant recipients by polymerase chain reaction (PCR) techniques and to separate the cases in which CMV related disease will occur, for whom treatment is indicated, from those in whom infection will remain innocuous. METHODS: The combination of qualitative and semiquantitative PCR of serum and urine was assessed to determine whether these assays can identify those at risk of CMV related disease and compared their performance with conventional approaches to diagnosis. RESULTS: Qualitative PCR of serum had superior specificity, sensitivity, and positive and negative predictive values compared with urine DEAFF (detection of early antigen fluorescent foci) and PCR of urine. All episodes of CMV related disease were associated with the presence of CMV DNA by PCR in serum or urine; CMV was detected before clinical onset in 70% and 60% of cases, respectively. The period over which CMV DNA could be detected was not correlated with CMV related disease. Both peak viral load and cumulative viral load estimated using a semiquantitative PCR method on serum samples positive by the qualitative method could be used to distinguish asymptomatic infection from CMV related disease with 100% specificity and sensitivity. In contrast semiquantitative PCR of urine was of little value. CONCLUSIONS: An approach based on PCR testing with a combination of qualitative and subsequently semiquantitative serum samples would improve the diagnosis of CMV infection and aid identification of those patients at risk of CMV related disease, allowing treatment to be targeted specifically.  (+info)

Primary adult liver transplantation under tacrolimus: more than 90 months actual follow-up survival and adverse events. (27/18686)

The introduction of tacrolimus has shown decreased rates of acute and steroid-resistant rejection after liver transplantation (LTx). The aim of the present study is to examine the long-term efficacy and safety of tacrolimus in primary liver transplant recipients. The first 121 consecutive adults (aged >16 years) who underwent primary LTx at a single center from August 1989 to February 1990 were followed up until August 1997. The mean follow-up was 93.2 +/- 1.2 months (range, 90.5 to 96.5 months). Patient survival, graft survival, rate of rejection, and adverse events were examined. The actual 7-year patient survival rate was 67.8%, and the graft survival rate was 63.6%. Infections, recurrence of disease, de novo malignancies, and cardiovascular events constituted the main causes of graft loss and death in the long term. Graft loss related to acute or chronic rejection was rare. The rate of acute rejection beyond 2 years was approximately 3% per year, and most rejections were steroid responsive. Approximately 70% of the patients received only tacrolimus after 1 year. Four patients developed end-stage renal disease, and 2 patients underwent kidney transplantation. Hyperkalemia and hypertension were observed in one third of the patients. New-onset insulin-dependent diabetes mellitus was observed in 9% and 13% of the patients at the 1-year and 7-year follow-up, respectively. Seven patients developed de novo malignancies, including two skin malignancies. Six patients developed posttransplantation lymphoproliferative disorder during the entire follow-up period. Actual patient and graft survival at 7 years was excellent, and few adverse events developed after the first year. Graft loss from acute or chronic rejection was rare under tacrolimus, and approximately 70% of the patients were steroid free on tacrolimus monotherapy after the first year after LTx.  (+info)

Total knee replacement: should it be cemented or hybrid? (28/18686)

OBJECTIVE: To compare the complication rates associated with total knee arthroplasty against the types of fixation (hybrid or cemented), using a single total knee design (the anatomic modular knee [AMK] prosthesis). DESIGN: A prospective, nonrandomized, controlled trial. SETTING: University Hospital in London, Ont., a tertiary care teaching centre. PATIENTS: Two groups made up of 484 knees in 395 patients (89 bilateral). INTERVENTIONS: In 260 knees a hybrid configuration (cemented tibia and noncemented femur) was used (group 1). In 224 knees the femoral and tibial components were cemented (group 2). All patellae were cemented in both groups. MAIN OUTCOME MEASURES: Clinical results were assessed by The Knee Society Clinical Rating Scores at 3 months, 6 months and yearly intervals. Radiographic results were determined by 3-foot standing radiographs and at each follow-up visit standing knee radiographs, lateral and skyline views. Radiographs were analysed for alignment, presence or absence of radiolucent lines or changes in the position of the implant. All reoperations and nonoperative complications were recorded. RESULTS: At an average follow-up of 4.8 years, 8 knees (1.6%) required reoperation. An analysis of the complications leading to reoperation demonstrated no difference between the 2 groups. CONCLUSIONS: There was no difference in outcome whether the femoral component was cemented or not. Medium-term results of the AMK are excellent with a very low reoperation rate.  (+info)

Bileaflet mechanical prostheses for aortic valve replacement in patients younger than 65 years and 65 years of age or older: major thromboembolic and hemorrhagic complications. (29/18686)

OBJECTIVE: To determine major thromboembolic and hemorrhagic complications and predictive risk factors associated with aortic valve replacement (AVR), using bileaflet mechanical prostheses (CarboMedics and St. Jude Medical). DESIGN: A case series. SETTING: Cardiac surgical services at the teaching institutions of the University of British Columbia. PATIENTS AND METHODS: Patients 2 age groups who had undergone AVR between 1989 and 1994 were studied. Group 1 comprised 384 patients younger than 65 years. Group 2 comprised 215 patients 65 years of age and older. RESULTS: The linearized rates of major thromboembolism (TE) occurring after AVR were 1.54%/patient-year for group 1 and 3.32%/patient-year for group 2; the rates for major TE occurring more than 30 days after AVR were 1.13%/patient-year for group 1 and 1.55%/patient-year for group 2. The crude rates for major TE occurring within 30 days of AVR were 1.04% for group 1 and 3.72% for group 2. The death rate from major TE in group 1 was 0.31%/patient-year and in group 2 was 0.88%/patient-year. Of the major TE events occurring within 30 days, 100% of patients in both age groups were inadequately anticoagulated at the time of the event, and for events occurring more than 30 days after AVR, 45% in group 1 and 57% in group 2 were inadequately anticoagulated (INR less than 2.0). The overall linearized rates of major hemorrhage were 1.54%/patient-year for group 1 and 2.21%/patient-year for group 2. There were no cases of prosthesis thrombosis in either group. The mean (and standard error) overall freedom from major TE for group 1 patients at 5 years was 95.6% (1.4%) and with exclusion of early events was 96.7% (1.3%); for group 2 patients the rates were 90.0% (3.2%) and 93.7% (3.0%), respectively. The mean (and SE) overall freedom from major and fatal TE and hemorrhage for group 1 patients was 90.1% (2.3%) and with exclusion of early events was 91.2% (2.3%); for group 2 patients the rates were 87.9% (3.1%) and 92.5% (2.9%), respectively. The 5-year rate for freedom from valve-related death for group 1 patients was 96.3% (2.1%) and for group 2 patients was 97.2% (1.2%). CONCLUSION: The thromboembolic and hemorrhagic complications after AVR with bileaflet mechanical prostheses occur more frequently and result in more deaths in patients 65 years of age and older than in patients years younger than 65 years.  (+info)

Evaluation of the allograft-prosthesis composite technique for proximal femoral reconstruction after resection of a primary bone tumour. (30/18686)

OBJECTIVE: To evaluate clinical and functional outcomes resulting from the allograft-composite technique used for proximal femoral osteoarticular reconstruction in patients who had limb salvage surgery for primary bone tumours. DESIGN: A retrospective review of a prospectively gathered database to provide a descriptive study. SETTING: A tertiary care musculoskeletal oncology unit in a university hospital. PATIENTS AND INTERVENTIONS: Patients treated between 1987 and 1993 were eligible for inclusion in this study if they met the following criteria: they were treated surgically for a primary malignant bone tumour; and a proximal femoral allograft-implant composite technique was used for the reconstruction. MAIN OUTCOME MEASURES: Major postoperative complications with emphasis on mechanical complications in the reconstructive composite implant. Functional outcome in a subset of patients using the 1987 and 1994 versions of the Musculoskeletal Tumor Society instrument, the Short-Form-36 and the Toronto Extremity Salvage Score. RESULTS: There were 5 mechanical and 2 infectious complications requiring surgical intervention. Functional scores were generally low. CONCLUSIONS: Our results suggest that the perceived benefits of the composite technique may accrue only to a few patients, partly owing to the risk of mechanical complications. Although these can be reduced by avoiding the use of cement in the host femur, the generally poor functional outcomes suggest that this technique needs to be studied further in this group of patients and compared with other reconstructive techniques, particularly the prosthetic implant.  (+info)

Disruption of skin perfusion following longitudinal groin incision for infrainguinal bypass surgery. (31/18686)

OBJECTIVE: The objective of our study was to investigate whether such an incision results in a reduction in blood flow, and therefore haemoglobin oxygen saturation, across the wound. DESIGN: Microvascular oxygenation was measured with lightguide spectrophotometry in 21 patients undergoing femoropopliteal or femorodistal bypass procedures. A series of measurements were made in the groin, medial and lateral to the surface marking of the femoral artery. The mean oxygen saturation on each side was calculated, and the contra-lateral groin was used as a control. The measurements were repeated at 2 and 7 days postop. RESULTS: Oxygen saturation in the skin of the operated groins was increased significantly from baseline at 2 days postop (f = 25.80, p < 0.001) and had begun to return to normal by day 7. The rise was more marked on the lateral side of the wound than on the medial (f = 12.32, p < 0.001). There was no such difference in the control groins. All wounds healed at 10 days. CONCLUSIONS: These results show a significant difference in skin oxygenation between the lateral and medial sides of the groin following longitudinal incision. This may contribute to the relatively high incidence of postoperative infection in these wounds.  (+info)

Frame dislocation of body middle rings in endovascular stent tube grafts. (32/18686)

OBJECTIVES: To understand the cause, and propose a mechanism for frame dislocation in endovascular grafts. MATERIALS AND METHODS: Five tube grafts were explanted due to secondary distal leakage 15-21 months after operation. One bifurcated graft was removed during emergency operation after aortic rupture caused by secondary leakage. A second bifurcated graft was harvested from a patient with thrombotic occlusion of one limb, who died after transurethral prostatic resection. The inside of the grafts were examined endoscopically. The stent was inspected after removal of the fabric, broken ligatures were counted and examined by scanning electron microscopy. The fabric strength was tested by probe puncture. RESULTS: We found 17-44% of the stent ligatures of the body middle rings to be loose. The knots were intact. Degradation of the polyester textile was not observed. CONCLUSIONS: Continuous movements in the grafted aorta and blood pressure impose permanent stress to the stent frame and the polyester fabric resulting in morphological changes in the body middle ring of grafts. The clinical implications of the suture breakages are unknown although they may be related to distal secondary leakage in tube grafts.  (+info)