Use of light handles in the laminar flow operating theatre--is it a cause of bacterial concern? (73/857)

Airborne bacteria introduced during routine joint replacement surgery are known to be an important source of joint sepsis with disastrous results. Recently, Robinson et al. [Robinson AHN, Bentley G, Drew S, Anderson J, Ridgway GL. Suction tip contamination in the ultraclean air operating theatre. Ann R Coll Surg Engl 1993; 75: 254-6] have demonstrated that the conventional surgical sucker forms a focus for airborne pathogens which results in septic loosening of hip prostheses. Similarly, the potential contamination of theatre light handles, commonly used during total hip and knee replacements, gives cause for concern. To assess if there was any evidence of contamination, we cultured bacterial swabs taken from the light handles before and after 15 such procedures, all of which were held in a conventional orthopaedic operating theatre. Fortunately, our study found no reason to stop the use of light handles in joint replacement operations.  (+info)

Viability of Acanthamoeba after exposure to a multipurpose disinfecting contact lens solution and two hydrogen peroxide systems. (74/857)

BACKGROUND/AIM: Contact lens cases contaminated with Acanthamoeba are a major risk factor for an infection of the eye. In this study the anti-Acanthamoeba activity of three different contact lens storage solutions was tested. METHODS: A new multipurpose contact lens storage solution (Meni Care Plus) and a two step (Titmus H(2)O(2)) and one step (Oxysept Comfort) hydrogen peroxide system were tested for their effects on trophozoites and cysts of three different Acanthamoeba species: A castellanii, A hatchetti, and A lenticulata. RESULTS: After a soaking time of 8 hours (overnight soaking of contact lenses) the Titmus H(2)O(2) 0.6% solution showed very good amoebicidal effects, while Oxysept Comfort 3% H(2)O(2) could not effectively destroy the cysts of any of the three tested species. Viable cysts of the species A lenticulata and A hatchetti were still present after exposure to Meni Care Plus (0.0005% PHMB) for 8 hours. CONCLUSION: Not all of the three tested contact lens storage solutions have sufficient amoebicidal effects. The two step peroxide system Titmus H(2)O(2) is a very effective disinfectant contact lens solution in order to avoid a possible Acanthamoeba infection of the eye.  (+info)

Use of a marker organism to model the spread of central nervous system tissue in cattle and the abattoir environment during commercial stunning and carcass dressing. (75/857)

Due to concerns about a link between variant Creutzfeldt-Jakob disease in humans and similar prion protein-induced disease in cattle, i.e., bovine spongiform encephalopathy (BSE), strict controls are in place to exclude BSE-positive animals and/or specified risk materials including bovine central nervous system (CNS) tissue from the human food chain. However, current slaughter practice, using captive bolt guns, may induce disruption of brain tissues and mobilize CNS tissues into the bovine circulatory system, leading to the dispersion of CNS tissues (including prion proteins) throughout the derived carcass. This project used a marker (antibiotic-resistant) strain of Pseudomonas fluorescens to model the effects of commercial captive bolt stunning procedures on the movement of mobilized CNS material within slaughtered animals and the abattoir environment. The marker organism, introduced by injection through the bolt entry aperture or directly using a cartridge-fired captive bolt, was detected in the slaughter environment immediately after stunning and in the abattoir environment at each subsequent stage of the slaughter-dressing process. The marker organism was also detected on the hands of operatives; on slaughter equipment; and in samples of blood, organs, and musculature of inoculated animals. There were no significant differences between the results obtained by the two inoculation methods (P < 0.05). This study demonstrates that material present in, or introduced into, the CNS of cattle during commercial captive bolt stunning may become widely dispersed across the many animate and inanimate elements of the slaughter-dressing environment and within derived carcasses including meat entering the human food chain.  (+info)

A rapid ELISA for the diagnosis of intravascular catheter related sepsis caused by coagulase negative staphylococci. (76/857)

AIM: To develop and evaluate a rapid enzyme linked immunosorbent assay (ELISA) for the diagnosis of intravascular catheter related sepsis caused by coagulase negative staphylococci. METHODS: Forty patients with a clinical and microbiological diagnosis of intravascular catheter related sepsis and positive blood cultures, caused by coagulase negative staphylococci, and 40 control patients requiring a central venous catheter as part of their clinical management were recruited into the study. Serum IgG responses to a previously undetected exocellular antigen produced by coagulase negative staphylococci, termed lipid S, were determined in the patient groups by a rapid ELISA. RESULTS: There was a significant difference (p = < 0.0001) in serum IgG to lipid S between patients with catheter related sepsis and controls. The mean antibody titre in patients with sepsis caused by coagulase negative staphylococci was 10 429 (range, no detectable serum IgG antibody to 99 939), whereas serum IgG was not detected in the control group of patients. CONCLUSIONS: The rapid ELISA offers a simple, economical, and rapid diagnostic test for suspected intravascular catheter related sepsis caused by coagulase negative staphylococci, which can be difficult to diagnose clinically. This may facilitate treatment with appropriate antimicrobials and may help prevent the unnecessary removal of intravascular catheters.  (+info)

Stethoscope: a friend or an enemy? (77/857)

CONTEXT: The stethoscope is a universal tool in the hospital that is in direct contact with many patients and can therefore be a vector in the dissemination of bacterial infections. OBJECTIVE: To research the presence of bacteria, fungi and yeast on the stethoscope diaphragm and the resistance of bacteria to antimicrobial drugs. DESIGN: Descriptive, prospective, non-controlled. SETTING: A tertiary care hospital. SAMPLE: Samples were taken randomly from 300 stethoscopes employed by medical staff (medical residents, medical students, nurses and nursing school students) and other sectors of the hospital. MAIN MEASUREMENTS: Three hundred stethoscope diaphragms used in several sectors of the hospital facilities by medical doctors (63 samples), medical residents (54 samples), medical students (106 samples), nursing school students (33 samples) and specific sectors (36 samples) were analyzed. Material was collected randomly. It was collected with the aid of a sterile swab moistened in physiological solution, inoculated into Brain Heart Infusion media and incubated in an oven for 24 to 48 hours. After this period, the samples were inoculated into blood agar, MacConkey agar and Sabouraud media and identified by Gram staining and biochemical assays. An assay to test bacteria sensitivity to antibiotics was also carried out by the Kirby-Bauer method. RESULTS: Eighty-seven percent of the analyzed stethoscopes were contaminated. Gram-positive cocci, yeasts, fungi and Gram-positive and negative bacilli were isolated. There was no significant association between the most predominant microorganisms and professional category. Staphylococcus aureus, Staphylococcus negative coagulase and Bacillus were significantly more frequent in relation to the presence of more than one microorganism on the stethoscope diaphragm. CONCLUSION: Stethoscopes presented a high rate of contamination and their use without precautions can spread nosocomial infections.  (+info)

Transfer of multiple drug resistance plasmids between bacteria of diverse origins in natural microenvironments. (78/857)

Plasmids harboring multiple antimicrobial-resistance determinants (R plasmids) were transferred in simulated natural microenvironments from various bacterial pathogens of human, animal, or fish origin to susceptible strains isolated from a different ecological niche. R plasmids in a strain of the human pathogen Vibrio cholerae O1 E1 Tor and a bovine Escherichia coli strain were conjugated to a susceptible strain of the fish pathogenic bacterium Aeromonas salmonicida subsp. salmonicida in marine water. Conjugations of R plasmids between a resistant bovine pathogenic E. coli strain and a susceptible E. coli strain of human origin were performed on a hand towel contaminated with milk from a cow with mastitis. A similar conjugation event between a resistant porcine pathogenic E. coli strain of human origin was studied in minced meat on a cutting board. Conjugation of R plasmids between a resistant strain of the fish pathogenic bacterium A. salmonicida subsp. salmonicida and a susceptible E. coli strain of human origin was performed in raw salmon on a cutting board. R plasmids in a strain of A. salmonicida subsp. salmonicida and a human pathogenic E. coli strain were conjugated to a susceptible porcine E. coli strain in porcine feces. Transfer of the different R plasmids was confirmed by plasmid profile analyses and determination of the resistance pattern of the transconjugants. The different R plasmids were transferred equally well under simulated natural conditions and under controlled laboratory conditions, with median conjugation frequencies ranging from 3 x 10(-6) to 8 x 10(-3). The present study demonstrates that conjugation and transfer of R plasmids is a phenomenon that belongs to the environment and can occur between bacterial strains of human, animal, and fish origins that are unrelated either evolutionarily or ecologically even in the absence of antibiotics. Consequently, the contamination of the environment with bacterial pathogens resistant to antimicrobial agents is a real threat not only as a source of disease but also as a source from which R plasmids can easily spread to other pathogens of diverse origins.  (+info)

Infected mediastinitis secondary to perforation of superior vena cava by a central venous catheter. (79/857)

We describe the first case of infected mediastinitis associated with central venous catheter insertion. The rare occurrence of this complication may be explained by the fact that it results from central venous catheter-related bloodstream infection and catheter perforation of superior vena cava. The symptoms of this complication (chest pain, dyspnoea) are not specific. Diagnosis should be confirmed by chest x-ray and computerized tomography which show hydromediastinum and pleural effusion. Removal and subsequent culture of the catheter tip will confirm infection. Appropriate antibiotic therapy, guided by sensitivities of the cultured organisms, should be commenced. Any pleural effusion should be drained by thoracocentesis, and the pleural fluid cultured. In case of fever, bacteraemia or shock, a thoracotomy to drain mediastinal and pleural effusions may be considered.  (+info)

Monitoring of presterile disposable syringes and needles marketed in Pune. (80/857)

Out of hundred syringes and hundred needles (both presterile, disposable) tested, 41 syringes (41%) and 6 needles (6%) showed aerobic growth. Forty of the above syringes were tested simultaneously for fungi and anaerobes. Fungi isolated were 5.7% and no anaerobe was grown. Fifty glass syringes and fifty needles autoclaved in the departmental laboratory served as controls and did not show any growth. As a preventive measure, proper disposal of used disposable material should be made mandatory so that it does not find its way into the market. Or has the time come to switch back to the former conventional practice of using in house autoclaved articles?  (+info)