The effects of microgravity on the development of surface righting in rats. (65/123)

The active interaction of neonatal animals with their environment has been shown to be a decisive factor in the postnatal development of sensory systems, which demonstrates a critical period in their maturation. The direct demonstration of such a dependence on the rearing environment has not been demonstrated for motor system function. Nor has the role of gravity in mammalian motor system development been investigated. Here we report the results of two space flight missions examining the effect of removing gravity on the development of surface righting. Since the essential stimulus that drives this synergy, gravitation, was missing, righting did not occur while the animals were in the microgravity environment. We hypothesize that this absence of contextual motor experience arrested the maturation of the motor tactics for surface righting. Such effects were permanent in rats spending 16 days (from postnatal day (P), P14 to P30), but were transient in animals spending nine days (from P15 to P24) in microgravity. Thus, active, contextual interaction with the environment during a critical period of development is necessary for the postnatal maturation of motor tactics as exemplified by surface righting, and such events must occur within a particular time period. Further, Earth's gravitational field is not assumed by the developing motor system. Rather, postnatal motor system development is appropriate to the gravitational field in which the animal is reared.  (+info)

Internal model of gravity for hand interception: parametric adaptation to zero-gravity visual targets on Earth. (66/123)

Internal model is a neural mechanism that mimics the dynamics of an object for sensory motor or cognitive functions. Recent research focuses on the issue of whether multiple internal models are learned and switched to cope with a variety of conditions, or single general models are adapted by tuning the parameters. Here we addressed this issue by investigating how the manual interception of a moving target changes with changes of the visual environment. In our paradigm, a virtual target moves vertically downward on a screen with different laws of motion. Subjects are asked to punch a hidden ball that arrives in synchrony with the visual target. By using several different protocols, we systematically found that subjects do not develop a new internal model appropriate for constant speed targets, but they use the default gravity model and reduce the central processing time. The results imply that adaptation to zero-gravity targets involves a compression of temporal processing through the cortical and subcortical regions interconnected with the vestibular cortex, which has previously been shown to be the site of storage of the internal model of gravity.  (+info)

Representation of visual gravitational motion in the human vestibular cortex. (67/123)

How do we perceive the visual motion of objects that are accelerated by gravity? We propose that, because vision is poorly sensitive to accelerations, an internal model that calculates the effects of gravity is derived from graviceptive information, is stored in the vestibular cortex, and is activated by visual motion that appears to be coherent with natural gravity. The acceleration of visual targets was manipulated while brain activity was measured using functional magnetic resonance imaging. In agreement with the internal model hypothesis, we found that the vestibular network was selectively engaged when acceleration was consistent with natural gravity. These findings demonstrate that predictive mechanisms of physical laws of motion are represented in the human brain.  (+info)

Sensory convergence solves a motion ambiguity problem. (68/123)

Our inner ear is equipped with a set of linear accelerometers, the otolith organs, that sense the inertial accelerations experienced during self-motion. However, as Einstein pointed out nearly a century ago, this signal would by itself be insufficient to detect our real movement, because gravity, another form of linear acceleration, and self-motion are sensed identically by otolith afferents. To deal with this ambiguity, it was proposed that neural populations in the pons and midline cerebellum compute an independent, internal estimate of gravity using signals arising from the vestibular rotation sensors, the semicircular canals. This hypothesis, regarding a causal relationship between firing rates and postulated sensory contributions to inertial motion estimation, has been directly tested here by recording neural activities before and after inactivation of the semicircular canals. We show that, unlike cells in normal animals, the gravity component of neural responses was nearly absent in canal-inactivated animals. We conclude that, through integration of temporally matched, multimodal information, neurons derive the mathematical signals predicted by the equations describing the physics of the outside world.  (+info)

How to activate a plant gravireceptor. Early mechanisms of gravity sensing studied in characean rhizoids during parabolic flights. (69/123)

Early processes underlying plant gravity sensing were investigated in rhizoids of Chara globularis under microgravity conditions provided by parabolic flights of the A300-Zero-G aircraft and of sounding rockets. By applying centrifugal forces during the microgravity phases of sounding rocket flights, lateral accelerations of 0.14 g, but not of 0.05 g, resulted in a displacement of statoliths. Settling of statoliths onto the subapical plasma membrane initiated the gravitropic response. Since actin controls the positioning of statoliths and restricts sedimentation of statoliths in these cells, it can be calculated that lateral actomyosin forces in a range of 2 x 10(-14) n act on statoliths to keep them in place. These forces represent the threshold value that has to be exceeded by any lateral acceleration stimulus for statolith sedimentation and gravisensing to occur. When rhizoids were gravistimulated during parabolic plane flights, the curvature angles of the flight samples, whose sedimented statoliths became weightless for 22 s during the 31 microgravity phases, were not different from those of in-flight 1g controls. However, in ground control experiments, curvature responses were drastically reduced when the contact of statoliths with the plasma membrane was intermittently interrupted by inverting gravistimulated cells for less than 10 s. Increasing the weight of sedimented statoliths by lateral centrifugation did not enhance the gravitropic response. These results provide evidence that graviperception in characean rhizoids requires contact of statoliths with membrane-bound receptor molecules rather than pressure or tension exerted by the weight of statoliths.  (+info)

Human ocular torsion and perceived roll responses to linear acceleration. (70/123)

We investigated if human ocular torsion (OT) and perceived roll (PR) are elicited in response to either dynamic interaural linear acceleration or dynamic roll tilt of the gravito-inertial force (GIF). We expanded a previous study [26] that measured only OT across a limited frequency-range (from 0.35 Hz to 1 Hz) by simultaneously measuring OT and PR at three very low (0.01, 0.02 and 0.05 Hz) and one high (1 Hz) frequencies. Three experimental conditions were investigated: (1) Y-Upright with acceleration along the interaural (Y) axis while upright, (2) Y-Supine with acceleration along the Y-axis while supine, and (3) Z-RED with acceleration along the rostro-caudal Z) axis with right-ear-down (RED). OT was measured by video-oculography, while PR was measured by use of a somatosensory bar. OT and PR were qualitatively different. Large OT responses were measured for Y-Upright and Y-Supine, while large perceived roll responses were observed for Y-Upright and Z-RED. OT for Z-RED was small, and PR for Y-Supine was absent. In conclusion, OT and PR appear governed by qualitatively different neural mechanisms. OT appears mostly influenced by central low-pass filtering of interaural graviceptor cues, while PR appears mostly influenced by roll tilt of the GIF.  (+info)

Shoot circumnutation and winding movements require gravisensing cells. (71/123)

Circumnutation and winding in plants are universal growth movements that allow plants to survive despite their sessile nature. However, the detailed molecular mechanisms controlling these phenomena remain unclear. We previously found that a gravitropic mutant of Japanese morning glory (Pharbitis nil or Ipomoea nil), Shidare-asagao (weeping), is defective not only in circumnutation but also in the winding response. This phenotype is similar to that of the Arabidopsis SCARECROW (SCR) mutant. We therefore investigated whether morning glory SCR (PnSCR) is involved in the weeping phenotype. We found that one amino acid was inserted into the highly conserved VHIID motif in weeping-type PnSCR; this mutation caused abnormal endodermal differentiation. We introduced either the mutant or WT PnSCR into Arabidopsis scr mutants for complementation tests. PnSCR of the WT, but not of weeping, rescued the shoot gravitropism and circumnutation of scr. These results show that both the abnormal gravitropism and the circumnutation defect in weeping are attributable to a loss of PnSCR function. Thus, our data show that gravisensing endodermal cells are indispensable for shoot circumnutation and the winding response and that PnSCR is responsible for the abnormal phenotypes of weeping.  (+info)

Differences in the accuracy of human visuospatial memory after yaw and roll rotations. (72/123)

Our ability to keep track of objects in the environment, even as we move, has been attributed to various cues including efference copies, vestibular signals, proprioception, and gravitational cues. However, the presence of some cues, such as gravity, may not be used to the same extent by different axes of motion (e.g., yaw vs. roll). We tested whether changes in gravitational cues can be used to improve visuospatial updating performance for yaw rotations as previously shown for roll. We found differences in updating for yaw and roll rotations in that yaw updating is not only associated with larger systematic errors but is also not facilitated by gravity in the same way as roll updating.  (+info)