The effect of cardiac contraction on collateral resistance in the canine heart. (1/7943)

We determined whether the coronary collateral vessels develop an increased resistance to blood flow during systole as does the cognate vascular bed. Collateral resistance was estimated by measuring retrograde flow rate from a distal branch of the left anterior descending coronary artery while the main left coronary artery was perfused at a constant pressure. Retrograde flow rate was measured before and during vagal arrest. We found that in 10 dogs the prolonged diastole experienced when the heart was stopped caused no significant change in the retrograde flow rate, which indicated that systole has little effect on the collateral resistance. However, when left ventricular end-diastolic pressure was altered by changing afterload or contractility, a direct relationship between end-diastolic pressure and collateral resistance was noted.  (+info)

Investigation of the theory and mechanism of the origin of the second heart sound. (2/7943)

To investigate further the origin of the second heart sound we studied human subjects, dogs, and a model in vitro of the cardiovascular system. Intra-arterial sound, pressure, and, where possible, flow and high speed cine (2,000 frames/sec) were utilized. The closure sound of the semilunar valves was of higher amplitude in be ventricles than in their respective arterial cavities. The direction of inscription of the main components of intra-arterial sound were opposite in direction to the components of intraventricular sound. Notches, representative of pressure increments, were noted on the ventricular pressure tracings and were coincident with the components of sound. The amplitude of the closure sound varied with diastolic pressure, but remained unchanged with augmentation of forward and retrograde aortic flow. Cines showed second sound to begin after complete valvular closure, and average leaflet closure rate was constant regardless of pressure. Hence, the semilunar valves, when closed, act as an elastic membrane and, when set into motion, generate compression and expansion of the blood, producing transient pressure changes indicative of sound. The magnitude of the initial stretch is related to the differential pressure between the arterial and ventricular chambers. Sound transients which follow the major components of the second sound appear to be caused by the continuing stretch and recoil of the leaflets. Clinically unexplained findings such as the reduced or absent second sound in calcific aortic stenosis and its paradoxical presence in congenital aortic stenosis may be explained by those observations.  (+info)

Flow-mediated vasodilation and distensibility of the brachial artery in renal allograft recipients. (3/7943)

BACKGROUND: Alterations of large artery function and structure are frequently observed in renal allograft recipients. However, endothelial function has not yet been assessed in this population. METHODS: Flow-mediated vasodilation is a useful index of endothelial function. We measured the diameter and distensibility of the brachial artery at rest using high-resolution ultrasound and Doppler frequency analysis of vessel wall movements in the M mode. Thereafter, changes in brachial artery diameter were measured during reactive hyperemia (after 4 min of forearm occlusion) in 16 cyclosporine-treated renal allograft recipients and 16 normal controls of similar age and sex ratio. Nitroglycerin-mediated vasodilation was measured to assess endothelium-independent vasodilation. Brachial artery blood pressure was measured using an automatic sphygmomanometer, and brachial artery flow was estimated using pulsed Doppler. RESULTS: Distensibility was reduced in renal allograft recipients (5.31 +/- 0. 74 vs. 9.10 +/- 0.94 x 10-3/kPa, P = 0.003, mean +/- sem), while the brachial artery diameter at rest was higher (4.13 +/- 0.14 vs. 3.25 +/- 0.14 mm, P < 0.001). Flow-mediated vasodilation was significantly reduced in renal allograft recipients (0.13 +/- 0.08 vs. 0.60 +/- 0.08 mm or 3 +/- 2 vs. 19 +/- 3%, both P < 0.001). However, nitroglycerin-mediated vasodilation was similar in renal allograft recipients and controls (0.76 +/- 0.10 vs. 0.77 +/- 0.09 mm, NS, or 19 +/- 3 vs. 22 +/- 2%, NS). There were no significant differences in brachial artery flow at rest and during reactive hyperemia between both groups. The impairments of flow-mediated vasodilation and distensibility in renal allograft recipients remained significant after correction for serum cholesterol, creatinine, parathyroid hormone concentrations, end-diastolic diameter, as well as blood pressure levels, and were also present in eight renal allograft recipients not treated with cyclosporine. Flow-mediated vasodilation was not related to distensibility in either group. CONCLUSIONS: The results show impaired endothelial function and reduced brachial artery distensibility in renal allograft recipients. The impairments of flow-mediated vasodilation and distensibility are not attributable to a diminished brachial artery vasodilator capacity, because endothelium-independent vasodilation was preserved in renal allograft recipients.  (+info)

Profile of neurohumoral agents on mesenteric and intestinal blood flow in health and disease. (4/7943)

The mesenteric and intestinal blood flow is organized and regulated to support normal intestinal function, and the regulation of blood flow is, in part, determined by intestinal function itself. In the process of the development and adaptation of the intestinal mucosa for the support of the digestive processes and host defense mechanisms, and the muscle layers for propulsion of foodstuffs, a specialized microvascular architecture has evolved in each tissue layer. Compromised mesenteric and intestinal blood flow, which can be common in the elderly, may lead to devastating clinical consequences. This problem, which can be caused by vasospasm at the microvascular level, can cause intestinal ischaemia to any of the layers of the intestinal wall, and can initiate pathological events which promote significant clinical consequences such as diarrhea, abdominal angina and intestinal infarction. The objective of this review is to provide the reader with some general concepts of the mechanisms by which neurohumoral vasoactive substances influence mesenteric and intestinal arterial blood flow in health and disease with focus on transmural transport processes (absorption and secretion). The complex regulatory mechanisms of extrinsic (sympathetic-parasympathetic and endocrine) and intrinsic (enteric nervous system and humoral endocrine) components are presented. More extensive reviews of platelet function, atherosclerosis, hypertension, diabetes mellitus, the carcinoid syndrome, 5-hydroxytryptamine and nitric oxide regulation of vascular tone are presented in this context. The possible options of pharmacological intervention (e.g. vasodilator agonists and vasoconstrictor antagonists) used for the treatment of abnormal mesenteric and intestinal vascular states are also discussed.  (+info)

Venous ulceration and continuous flow in the long saphenous vein. (5/7943)

OBJECTIVE: To determine the clinical significance of continuous flow in the long saphenous vein in limbs with venous ulceration. DESIGN: Retrospective review. PATIENTS AND METHODS: Review of 1608 consecutive limbs undergoing colour duplex scanning for venous disease over a 43 month period. RESULTS: Continuous flow in the long saphenous vein is seen in 8% of limbs with venous ulceration and in 37% of limbs with deep venous obstruction. Sixty-six per cent of ulcerated limbs with continuous flow in the long saphenous vein had deep venous obstruction, 27% had deep venous reflux with cellulitis and 7% had lymphoedema in addition to venous ulceration. CONCLUSION: Continuous flow in the long saphenous vein in patients with venous ulceration should alert the clinician to the possibility of deep venous obstruction. Such limbs should be treated by compression bandaging with extreme caution.  (+info)

Brightness alters Heidelberg retinal flowmeter measurements in an in vitro model. (6/7943)

PURPOSE: The Heidelberg Retinal Flowmeter (HRF), a laser Doppler flowmetry device, has captured interest as a research and clinical tool for measurement of ocular blood flow. Concerns remain about the range and accuracy of the values that it reports. METHODS: An in vitro blood-flow model was constructed to provide well-controlled laminar flow through a glass capillary for assessment by HRF. A change in material behind the glass capillary was used to simulate changing brightness conditions between eyes. RESULTS: Velocities reported by the HRF correlated linearly to true velocities below 8.8 mm/sec. Beyond 8.8 mm/sec, HRF readings fluctuated randomly. True velocity and HRF reported velocities were highly correlated, with r = 0.967 (P < 0.001) from 0.0 mm/sec to 2.7 mm/sec mean velocity using a light background, and r = 0.900 (P < 0.001) from 2.7 mm/sec to 8.8 mm/sec using a darker background. However, a large change in the y-intercept occurred in the calibration curve with the background change. CONCLUSIONS: The HRF may report velocities inaccurately because of varying brightness in the fundus. In the present experiment, a darker background produced an overreporting of velocities. An offset, possibly introduced by a noise correction routine, apparently contributed to the inaccuracies of the HRF measurements. Such offsets vary with local and global brightness. Therefore, HRF measurements may be error prone when comparing eyes. When used to track perfusion in a single eye over time, meaningful comparison may be possible if meticulous care is taken to align vessels and intensity controls to achieve a similar level of noise correction between measurements.  (+info)

Analysis of blood flow in the long posterior ciliary artery of the cat. (7/7943)

PURPOSE: Experiments were undertaken to use a new technique for direct on-line measurement of blood flow in the long posterior ciliary artery (LPCA) in cats and to evaluate possible physiological mechanisms controlling blood flow in the vascular beds perfused by this artery. METHODS: Blood flow in the temporal LPCA was measured on a continuous basis using ultrasonic flowmetry in anesthetized cats. Effects of acute sectioning of the sympathetic nerve and changes in LPCA and cerebral blood flows in response to altered levels of inspired CO2 and O2 were tested in some animals. In others, the presence of vascular autoregulatory mechanisms in response to stepwise elevations of intraocular pressure was studied. RESULTS: Blood flow in the temporal LPCA averaged 0.58+/-0.03 ml/min in 45 cats anesthetized with pentobarbital. Basal LPCA blood flow was not altered by acute sectioning of the sympathetic nerve or by changes in low levels of inspired CO2 and O2, although 10% CO2 caused a modest increase. Stepwise elevations of intraocular pressure resulted in comparable stepwise decreases of LPCA blood flow, with perfusion pressure declining in a linear manner throughout the perfusion-pressure range. CONCLUSIONS: Ultrasonic flowmetry seems to be a useful tool for continuous on-line measurement of LPCA blood flow in the cat eye. Blood flow to vascular beds perfused by this artery does not seem to be under sympathetic neural control and is refractory to modest alterations of blood gas levels of CO2 and O2. Blood vessels perfused by the LPCA show no clear autoregulatory mechanisms.  (+info)

Demonstration of rapid onset vascular endothelial dysfunction after hyperhomocysteinemia: an effect reversible with vitamin C therapy. (8/7943)

BACKGROUND: Hyperhomocysteinemia is a major and independent risk factor for vascular disease. The mechanisms by which homocysteine promotes atherosclerosis are not well understood. We hypothesized that elevated homocysteine concentrations are associated with rapid onset endothelial dysfunction, which is mediated through oxidant stress mechanisms and can be inhibited by the antioxidant vitamin C. METHODS AND RESULTS: We studied 17 healthy volunteers (10 male and 7 female) aged 33 (range 21 to 59) years. Brachial artery diameter responses to hyperemic flow (endothelium dependent), and glyceryltrinitrate (GTN, endothelium independent) were measured with high resolution ultrasound at 0 hours (fasting), 2 hours, and 4 hours after (1) oral methionine (L-methionine 100 mg/kg), (2) oral methionine preceded by vitamin C (1g/day, for 1 week), and (3) placebo, on separate days and in random order. Plasma homocysteine increased (0 hours, 12.8+/-1.4; 2 hours, 25.4+/-2.5; and 4 hours, 31. 2+/-3.1 micromol/l, P<0.001), and flow-mediated dilatation fell (0 hours, 4.3+/-0.7; 2 hours, 1.1+/-0.9; and 4 hours, -0.7+/-0.8%) after oral L-methionine. There was an inverse linear relationship between homocysteine concentration and flow-mediated dilatation (P<0. 001). Pretreatment with vitamin C did not affect the rise in homocysteine concentrations after methionine (0 hours, 13.6+/-1.6; 2 hours, 28.3+/-2.9; and 4 hours, 33.8+/-3.7 micromol/l, P=0.27), but did ameliorate the reduction in flow-mediated dilatation (0 hours, 4. 0+/-1.0; 2 hours, 3.5+/-1.2 and 4 hours, 2.8+/-0.7%, P=0.02). GTN-induced endothelium independent brachial artery dilatation was not affected after methionine or methionine preceded by vitamin C. CONCLUSIONS: We conclude that an elevation in homocysteine concentration is associated with an acute impairment of vascular endothelial function that can be prevented by pretreatment with vitamin C in healthy subjects. Our results support the hypothesis that the adverse effects of homocysteine on vascular endothelial cells are mediated through oxidative stress mechanisms.  (+info)