Intradural herniation of intervertebral disc at the level of Lumbar 1-Lumbar 2. (73/280)

Intradural disc herniation is a serious and rare complication of intervertebral disc rupture. The preoperative diagnosis of intradural disc herniation is still difficult despite new neuroradiologic investigation possibilities including computerized tomography and magnetic resonance imaging and it is usually diagnosed by during surgery. Here we present an intradural disc herniation case at the level of L1-L2 with accompanying significant myelopathic neurologic deficits. A 50-year-old female patient was admitted to the hospital with pain and weakness in both legs. Her neurological examination revealed paraparesis. Magnetic resonance imaging showed an extruded disc hernia of central localization at the L1-L2 level. She underwent total laminectomy at the level of L1-L2 and her intradural disc fragment was extirpated by microsurgical methods.  (+info)

Gadolinium-enhanced MR cisternography to evaluate dural leaks in intracranial hypotension syndrome. (74/280)

BACKGROUND AND PURPOSE: We evaluated the use of MR cisternography after intrathecal administration of gadopentetate dimeglumine to detect the presence and localization of CSF leaks in 19 patients diagnosed with spontaneous intracranial hypotension syndrome according to the criteria of International Headache Society. MATERIALS AND METHODS: Lumbar puncture with an injection of 0.5 mL of gadopentetate dimeglumine into the subarachnoid space in the lumbar area was performed. MR images of the cervical, thoracic, and lumbar regions in axial, coronal, and sagittal planes with fat-saturated T1-weighted images were acquired. RESULTS: We observed objective CSF leakage in 17 (89%) of 19 patients. In 14 of these 17 patients, the site of dural tear was demonstrated accurately. In 3 of these 17 patients, the contrast leakage was diffuse, and site of the leak could not be located accurately. No leakage was observed in 2 patients. No complications were detected in any of the patients during the first 24 hours after the procedure or during the 6- to 12-month follow-up. CONCLUSION: The current results demonstrate the relative safety, accuracy, and feasibility of intrathecal gadolinium-enhanced MR cisternography to evaluate dural leaks.  (+info)

A comparison of angiographic CT and multisection CT in lumbar myelographic imaging. (75/280)

BACKGROUND AND PURPOSE: The purpose of this work was to provide an intraindividual comparison of angiographic CT (ACT) and multisection CT (MSCT) in lumbar myelographic imaging and to evaluate possible benefits of ACT, which is a further development of rotational angiography providing image data of high spatial and CT-like contrast resolution. MATERIALS AND METHODS: In 26 patients with degenerative lumbar spine disease a lumbar ACT was performed in combination with conventional lumbar myelography and followed by postmyelographic MSCT. Conventional lumbar myelography and lumbar ACT were performed with a flat panel detector-equipped angiographic device. Postmyelographic MSCT was performed with a 16-section CT scanner. Three experienced neuroradiologists rated anonymized sets of multiplanar reformatted CT and ACT images regarding diagnostic and technical parameters. The ratings were repeated after 2 months. Weighted kappa statistics were calculated to describe the levels of intraobserver and interobserver agreement. RESULTS: The analysis shows that MSCT achieves higher ratings than ACT in all of the parameters asked. An adequate diagnostic quality was only assigned to 80% of the ACT acquisitions compared with 97% of the MSCT acquisitions. All of the mean kappa values were above 0.60, demonstrating a substantial intraobserver and interobserver agreement for MSCT, as well as for ACT. CONCLUSION: Using ACT, radiographic myelography and myelographic CT can be performed at the same imaging system. However, the results of our study show that the current myelographic ACT image quality fails to apply diagnostic standards. We, therefore, cannot recommend ACT as a general alternative to postmyelographic MSCT.  (+info)

Concomitant noncontiguous level (thoracic & lumbar) spinal stenosis. (76/280)

 (+info)

A review of spinal arachnoid cysts. (77/280)

The symptoms of spinal arachnoid cysts are variable and nonspecific, so they are commonly misdiagnosed. Often the cysts are discovered incidentally on magnetic resonance imaging (MRI). If they cause no symptoms, no treatment is warranted regardless of the size of the cyst. Cysts that cause symptoms from mechanical compression of the spinal cord are best evaluated with MRI and surgically excised if possible.  (+info)

Emergent image-guided treatment of a large CSF leak to reverse "in-extremis" signs of intracranial hypotension. (78/280)

 (+info)

The difference of contrast effects of myelography in normal dogs: comparison of iohexol (180 mgI/ml), iohexol (240 mgI/ml) and iotrolan (240 mgI/ml). (79/280)

The contrast effects of three different contrast media preparations (iohexol 180 mgI/ml, iohexol 240 mgI/ml and iotrolan 240 mgI/ml) in conventional and CT myelography were compared. Three beagle dogs were used and the study employed a cross-over method (total of 9) for each contrast media. The result of CT myelography showed that the contrast effect of iohexol (180 mgI/ml), which had low viscosity, was highest in cranial sites, and the contrast effect of high-viscosity iotrolan (240 mgI/ml) was highest in caudal sites 5 min after injection of the contrast media preparations. This shows that the diffusion of contrast media preparations in the subarachnoid space is influenced by viscosity. The results of conventional myelography also showed that the diffusion of contrast media preparations is influenced by viscosity. Therefore, it is important to identify the location of spinal lesions in veterinary practice, and low viscosity contrast medium preparation with wide spread contrast effects is considered suitable for myelography.  (+info)

Influence of flexion-extension motion of lumbar spine on lumbosacral dural sac. An experimental study. (80/280)

To analyze the effects of flexion-extension motion of lumbar spine on the position and shape of lumbosacral dural sac, 10 flexion/extension lateral myelograms of cadaver specimens of normal lumbar spine were measured. The results showed that moving from flexion to extension both sagittal diameter and length of the dural sac decreased significantly, the dural sac moved caudally, and the sagittal diameter of the anterior epidural space decreased in the mid-vertebral level but increased in the intervertebral level. The dynamic changes of the dural sac and their influence factors and clinical relevance were discussed.  (+info)