Loading...
*  Salicylate testing
Abbott Labs' AxSYM is an immunoassay device utilizing Fluorescence Polarization Immunoassay (FPIA) technology that can ... Polarization allows the machine to detect the difference between antibody bound, and unbound fluorescein. It is therefore ...
*  Fluorescence polarization immunoassay
"Fluorescence Polarization Immunoassay II. Analyzer for Rapid, Precise Measurement of Fluorescence Polarization with Use of ... which results in altered fluorescence polarization. Fluorescence polarization immunoassays employ a fluorophore bound antigen ... The solution is evaluated again by the fluorescence polarization analyzer. The fluorescence polarization value for the tracer ... Fluorescence polarization immunoassay (FPIA) is a class of in vitro biochemical test used for rapid detection of antibody or ...
*  Oleandrin
Fluorescence polarization immunoassay is widely used. This test is slower and has a lower sensitivity than digoxin immunoassay ... "Rapid detection of oleander poisoning using fluorescence polarization immunoassay for digitoxin. Effect of treatment with ... and their detection by digoxin immunoassays". Clinical Chemistry. 42 (10): 1654-8. PMID 8855150. Ibrahim, Amany K.; Khalifa, ...
*  Pholcodine
... fluorescence polarisation immunoassay, enzyme immunoassay and gas chromatography-mass spectrometry". International Journal of ... "Toxicological detection of pholcodine and its metabolites in urine and hair using radio immunoassay, ...
*  List of MeSH codes (E05)
... fluorescence polarization MeSH E05.196.712.516.600.390.350 --- fluorescence polarization immunoassay MeSH E05.196.712.516. ... fluorescence polarization immunoassay MeSH E05.478.588.400 --- immunoenzyme techniques MeSH E05.478.588.400.170 --- enzyme- ... fluorescence MeSH E05.196.712.516.600.676.500 --- fluorescence resonance energy transfer MeSH E05.196.712.650 --- nephelometry ... fluorescence MeSH E05.200.500.620.670.325.350.125 --- chromosome painting MeSH E05.200.500.620.670.325.680 --- primed in situ ...
*  List of MeSH codes (E01)
... fluorescence polarization immunoassay MeSH E01.450.495.375 --- hemolytic plaque technique MeSH E01.450.495.385 --- ... fluorescence MeSH E01.370.350.515.458.500 --- microscopy, fluorescence, multiphoton MeSH E01.370.350.515.513 --- microscopy, ... polarization MeSH E01.370.350.515.666 --- microscopy, scanning probe MeSH E01.370.350.515.666.400 --- microscopy, atomic force ... immunoassay MeSH E01.450.495.410.320 --- immunoblotting MeSH E01.450.495.410.320.100 --- blotting, western MeSH E01.450.495.410 ...
*  Phosphorylation
... including fluorescence immunoassays, Microscale thermophoresis, FRET, TRF, fluorescence polarization, fluorescence-quenching, ...
*  FluoProbes
... life time resolved fluorescence (TRF), polarisation anisotropy fluorescence, FRET, Quenching, FRAP. They are typically used in ... suit direct use in immunoassays or cell assays. FluoProbes dyes that have comparable excitation and emission spectra to ... biotechnology and research applications as fluorescence microscopy, cell biology or molecular biology, as well as infrared ...
*  Plate reader
... time-resolved fluorescence, and fluorescence polarization) are available stand-alone in dedicated plate readers, but are very ... and viability ATP quantification Immunoassays High throughput screening of compounds and targets in drug discovery While "plate ... time-resolved fluorescence, and fluorescence polarization. Absorbance detection has been available in microplate readers for ... Fluorescence polarization measurement is also very close to FI detection. The difference is that the optical system includes ...
*  Protein quaternary structure
... fluorescence polarization (measures the rotational diffusion constant) dielectric relaxation (measures the rotational diffusion ... sedimentation-equilibrium analytical ultracentrifugation electrospray mass spectrometry Mass Spectrometric Immunoassay MSIA ... constant) Dual polarisation interferometry (measures the size and the density of the complex) Methods that measure the mass or ... static light scattering size exclusion chromatography (requires calibration) Dual polarisation interferometry sedimentation- ...
*  Ligand binding assay
Fluorescence polarization is synonymous with fluorescence anisotropy. This method measures the change in the rotational speed ... Immunoassay Luckey, J.; et al. (1993). "[12] High-speed DNA sequencing by capillary gel electrophoresis". Methods in Enzymology ... These methods include, but are not limited to, fluorescence polarization (FP), fluorescence resonance energy transfer (FRET), ... As a result, change in dye fluorescence can be viewed in real time with no delay using an excitatory laser and a charge-coupled ...
*  Time-resolved fluorescence energy transfer
... such as fluorescence polarization (FP) or TRF assays. In FP assays, background fluorescence due to library compounds is ... "Resonance Energy Transfer in Steady-State and Time-Decay Fluoro-Immunoassays for Lanthanide Nanoparticles Based on Biotin and ... Time-resolved fluorescence energy transfer (TR-FRET) is the practical combination of time-resolved fluorometry (TRF) with ... This energy is then released by APC as specific fluorescence at 665 nm only via FRET with Europium. The following are ...
*  Surface plasmon resonance
... and dual polarization interferometry. The first SPR immunoassay was proposed in 1983 by Liedberg, Nylander, and Lundström, then ... Surface plasmons have been used to enhance the surface sensitivity of several spectroscopic measurements including fluorescence ... Unlike many other immunoassays, such as ELISA, an SPR immunoassay is label free in that a label molecule is not required for ... In the case of p-polarized light (polarization occurs parallel to the plane of incidence), this is possible by passing the ...
*  Bio-MEMS
... fluorescence resonance energy transfer) in optical signal indicates a reaction has occurred. Fluorescence-based detection has ... Paper microfluidics have been applied in paper electrophoresis and immunoassays, the most notable being the commercialized ... Dielectrophoresis is the motion of uncharged particles due to induced polarization from nonuniform electric fields. ... Optical detection includes fluorescence-based techniques, chemiluminescence-based techniques, and surface plasmon resonance ( ...
*  Biosensor
A fluorescent biosensor reacts to the interaction with its target analyte by a change of its fluorescence properties. A ... One such example, dual polarisation interferometry uses a buried waveguide as a reference against which the change in ... definitively boosted ECL for immunoassay, as confirmed by many research applications and, even more, by the presence of ... Other optical biosensors are mainly based on changes in absorbance or fluorescence of an appropriate indicator compound and do ...
*  Thermal shift assay
The fluorescence in each well is measured at regular intervals, 0.2-1 °C/image, over a temperature range spanning the typical ... and dual polarization interferometry (DPI)". Acta Crystallographica Section D. 71 (Pt 1): 36-44. doi:10.1107/s1399004714016617 ... "His-tag protein monitoring by a fast mix-and-measure immunoassay". Scientific Reports. 4: 5613. doi:10.1038/srep05613. PMC ... Since only fluorescence is measured, only the tagged protein is seen in the chromatogram. FSEC is typically used to compare ...
*  Proteomics
Fluorescence two-dimensional differential gel electrophoresis (2-D DIGE) can be used to quantify variation in the 2-D DIGE ... Examples of these methods are the MSIA (mass spectrometric immunoassay) developed by Randall Nelson in 1995 and the SISCAPA ( ... Other methods include surface plasmon resonance (SPR), protein microarrays, dual polarisation interferometry, microscale ... 1995). "Mass Spectrometric Immunoassay". Analytical Chemistry. 67 (7): 1153-1158. doi:10.1021/ac00103a003. ISSN 0003-2700. PMID ...
*  Surface plasmon resonance microscopy
Fluorescence-based microscopy (FLM) can be used to study the interactions of membrane proteins in individual cells but it ... Kanda, V; Kariuki, J, K; Harrison, D, J; McDermott, M, T (2004). "Label-Free Reading of Microarray-Based Immunoassays with ... Electrons in the conduction band induce polarization after interaction with the electric field of the radiation. A net charge ... SPR microscopy (SPRM) makes possible to simultaneously optical and fluorescence imaging of the same sample, which prove to get ...