Loading...
*  Salicylate testing
Abbott Labs' AxSYM is an immunoassay device utilizing Fluorescence Polarization Immunoassay (FPIA) technology that can ... Polarization allows the machine to detect the difference between antibody bound, and unbound fluorescein. It is therefore ...
*  Evanescent field
For the polarization considered in this example, the conditions on E,, and By are satisfied if the reflected wave has the same ... A total internal reflection fluorescence microscope uses the evanescent wave produced by total internal reflection to excite ... Here α and β are real and i represents the imaginary unit.) For example, if the polarization is perpendicular to the plane of ... and the polarization along z. One might naively expect that for angles leading to total internal reflection, the solution would ...
*  Fluorescence polarization immunoassay
The solution is evaluated again by the fluorescence polarization analyzer. The fluorescence polarization value for the tracer ... "Fluorescence Polarization Immunoassay II. Analyzer for Rapid, Precise Measurement of Fluorescence Polarization with Use of ... and is measured by a fluorescence polarization analyzer. Fluorescence polarization was first observed by F. Weigert in 1920. He ... which results in altered fluorescence polarization. Fluorescence polarization immunoassays employ a fluorophore bound antigen ...
*  Oleandrin
Fluorescence polarization immunoassay is widely used. This test is slower and has a lower sensitivity than digoxin immunoassay ... "Rapid detection of oleander poisoning using fluorescence polarization immunoassay for digitoxin. Effect of treatment with ...
*  Plate reader
... time-resolved fluorescence, and fluorescence polarization) are available stand-alone in dedicated plate readers, but are very ... time-resolved fluorescence, and fluorescence polarization. Absorbance detection has been available in microplate readers for ... Fluorescence polarization measurement is also very close to FI detection. The difference is that the optical system includes ... Time-resolved fluorescence (TRF) measurement is very similar to fluorescence intensity (FI) measurement. The only difference is ...
*  Virus-like particle
"Cell-free assay of G-protein-coupled receptors using fluorescence polarization". Journal of Biomolecular Screening. 13 (5): 424 ...
*  NanoRacks
It can operate in absorbance, fluorescence intensity, or fluorescence polarization modes. Lab space on the ISS is provided to ...
*  Silicon-vacancy center in diamond
"Fluorescence Polarization Switching from a Single Silicon Vacancy Colour Centre in Diamond". Scientific Reports. 5: 12244. ...
*  Ligand binding assay
Fluorescence polarization is synonymous with fluorescence anisotropy. This method measures the change in the rotational speed ... These methods include, but are not limited to, fluorescence polarization (FP), fluorescence resonance energy transfer (FRET), ... As a result, change in dye fluorescence can be viewed in real time with no delay using an excitatory laser and a charge-coupled ... It binds to free Ca2+ ions, which in turn slightly increase fluorescence of the Fluo-4 AM. The drawback of the Fluo-4 dye ...
*  Arctiin
"Identification of adiponectin receptor agonist utilizing a fluorescence polarization based high throughput assay". PLoS ONE. 8 ...
*  Bcl-2-associated death promoter
Zhang H, Nimmer P, Rosenberg SH, Ng SC, Joseph M (August 2002). "Development of a high-throughput fluorescence polarization ...
*  Bcl-2-associated X protein
Zhang H, Nimmer P, Rosenberg SH, Ng SC, Joseph M (2002). "Development of a high-throughput fluorescence polarization assay for ...
*  Bcl-2
Zhang H, Nimmer P, Rosenberg SH, Ng SC, Joseph M (Aug 2002). "Development of a high-throughput fluorescence polarization assay ...
*  Methods to investigate protein-protein interactions
The increase in the polarization of the fluorescence upon binding of the labeled protein to its binding partner can be used to ... Fluorescence polarization/anisotropy can be used to measure protein-protein or protein-ligand interactions. Typically one ... With fluorescence correlation spectroscopy, one protein is labeled with a fluorescent dye and the other is left unlabeled. The ... Dual polarisation interferometry (DPI) can be used to measure protein-protein interactions. DPI provides real-time, high- ...
*  BCL2-like 1 (gene)
Zhang H, Nimmer P, Rosenberg SH, Ng SC, Joseph M (Aug 2002). "Development of a high-throughput fluorescence polarization assay ...
*  4EGI-1
Compounds that displace the labeled peptide from eIF4E would yield a decrease in fluorescence polarization. The sequence of ... researchers developed a high-throughput fluorescence polarization (FP)-binding assay. In this assay, a small peptide of a known ...
*  Fluorescence anisotropy
... or fluorescence polarization is the phenomenon where the light emitted by a fluorophore has unequal ... Principles of Fluorescence Spectroscopy (3rd ed., Springer. Chapter 10-12 deal with fluorescence polarization spectroscopy.) ... Principles of Fluorescence Spectroscopy (3rd ed., Springer. Chapter 10-12 deal with fluorescence polarization spectroscopy.) " ... The principles of fluorescence polarization and some applications of the method are presented in Lakowicz's book. The ...
*  Time-resolved fluorescence energy transfer
... such as fluorescence polarization (FP) or TRF assays. In FP assays, background fluorescence due to library compounds is ... Time-resolved fluorescence energy transfer (TR-FRET) is the practical combination of time-resolved fluorometry (TRF) with ... This energy is then released by APC as specific fluorescence at 665 nm only via FRET with Europium. The following are ... Certain life science applications take advantage of the unique fluorescence properties of lanthanide ion complexes (Ln(III) ...
*  Nancy Sottos
... the MC subspecies relative to the tensile force could be characterized based on the anisotropy of the fluorescence polarization ...
*  6-Methylisoxanthopterin
This allows 6MI to be used to probe the dynamics of DNA or RNA helices using a technique such as fluorescence polarization ... "Photophysical Characterization of Enhanced 6-Methylisoxanthopterin Fluorescence in Duplex DNA". doi:10.1021/acs.jpcb.6b07369. ...
*  Robert Alfano
He was pioneer to conduct ultrafast time-resolved techniques in picosecond ranges to study fluorescence polarization dynamics ... This observation has enabled noninvasive detection of cancer based on fluorescence ratio, and obtaining a fluorescence ratio ... In 1984, he was the first to detect cancer using the native fluorescence spectroscopy of tissue without extrinsic dyes. In a ... In fact, he introduced the term "optical biopsy." In 1981 Alfano used fluorescence spectroscopy and time-resolved kinetics to ...
*  Pholcodine
... fluorescence polarisation immunoassay, enzyme immunoassay and gas chromatography-mass spectrometry". International Journal of ...
*  Neothramycin
The data collected also showed that pyrrolo(1,4)benzodiazepines can also be used to measure the fluorescence polarization ... These compounds were tested using a fluorescence based assay. These compounds showed an ability to bind dG-containing DNA ... and even possible uses in DNA fluorescence based assays. Its activities against cancer warranted phase I testing of the drug. ...
*  Phosphorylation
... fluorescence polarization, fluorescence-quenching, mobility shift, bead-based detection, and cell-based formats. ATP, the "high ... There are also several quantitative protein phosphorylation methods, including fluorescence immunoassays, Microscale ...
*  KIAA1211L
... fluorescence polarization spectroscopy, protein kinases assay, two hybrid, and confocal microscopy experiments. KIAA1211L ...
*  Mie scattering
In the small-particle (or long-wavelength) limit, conditions can occur for zero forward scatter, for complete polarization of ... "Rapid in situ determination of total oil concentration in water using ultraviolet fluorescence and light scattering coupled ... The special case in the small-particle limit provides interesting special instances of complete polarization and forward- ...
*  Gregorio Weber
Polarization of the fluorescence of macromolecules. I. Theory and experimental method and Polarization of the fluorescence of ... At that time he began to delve more deeply into the theory of fluorescence polarization and also began to develop methods which ... "These values are too short to permit measurements of fluorescence polarization to be of value in the determination of the ... the extension of Perrin's theory of fluorescence polarization to fluorophores associated with random orientations with ...