The Olympus Bronchoscope is just one of the bronchoscopes available to medical centers; however, Olympus voluntarily recalled 4,400 products, of which 2,300 were in use at hospitals, in 2001. It was believed that bacteria could grow on the instruments, and cause infections in patients. An Olympus Bronchoscope was designed to examine a patient for lung infections, pneumonia, and lung cancer. A bronchoscope is a tube that has an attached camera. Qualified physicians will place the tube through a patient\\\s nose or mouth, in order to look into their lungs. Bronchoscopes employ fiber optic technology to evaluate a patient\\\s airways and rule out respiratory problems. In 2001, when Olympus put in effect a fifteen-model voluntary recall, it was discovered that the Bronchoscopes, though being cleaned properly, still contained bacteria. This bacteria is called pseudomonas, which can cause disease in humans and animals. It was being trapped by the bronchoscope and could spread to patients, and ...
The simple solution, then, is to switch to sterilization, right? While the study recommends hospitals consider using sterilization or single-use bronchoscopes to prevent spreading infection to patients through contaminated bronchoscopes, sterilization comes with its own set of challenges.. Those include longer turnaround times, expensive machinery and additional supplies.. The study, "Managing Bronchoscope Quality and Cost: Results of a real-world study," was conducted by Cori L. Ofstead, MSPH; Krystina M. Hopkins, MPH; John E. Eiland, RN, MS; and Harry P. Wetzler, MD, MSPH. It builds on a related study last year, published in Chest Journal, that examined the effectiveness of the cleaning processes for reusable bronchoscopes.. Bronchoscopes, a type of endoscope, are delicate instruments that enable practitioners to see the airways to the lungs and perform interventions such as lung biopsies or removing pus and tumors. Reusable bronchoscopes also pose a high risk of cross-contamination. Sterile, ...
Despite the advances in optical technology, proper training and experience is crucial to optimise the outcome and minimise the risk of complications in tracheobronchial foreign body removal by a bronchoscope.. Although the rigid bronchoscope is still considered as the safest instrument in most paediatric centres, there is no doubt that the fibreoptic bronchoscope is the preferred tool for the initial diagnosis of a foreign body in adult patients.2,19,32 At present flexible bronchoscopes in different sizes are available for different age groups. The bronchoscopes with 4.9 mm outer diameter and a 2.2 mm diameter working channel are used in patients older than 12 years of age. Although bronchoscopes with 3.5 mm or 2.7 mm outer diameter with 1.2 mm diameter working channels are available for younger patients, using the flexible bronchoscope under local anaesthesia in a very young patient is a very difficult procedure. In such cases, rigid bronchoscopy under general anaesthesia is probably the safest ...
This paper describes the investigation of an unexpected rise in the number of bronchoscopic cultures growing Pseudomonas and Serratia spp in a community hospital. Over a 4 month period 20 of 43 samples tested positive for one or both organisms. All 20 positive cultures were from procedures performed using newly purchased bronchoscopes. Identical organisms were isolated from the biopsy port of the new bronchoscopes and the sink trap in the endoscopy unit. One patient was readmitted with Pseudomonas pneumonia. During the same period there were no positive samples from older bronchoscopes used in the department. The biopsy port cap was found to be loose on all four new bronchoscopes. The manufacturer subsequently recalled approximately 14 000 bronchoscopes worldwide for modification. New devices are less likely than drugs to have their safety established clinically before they are marketed. Effective surveillance of marketed medical devices could identify low frequency adverse events including ...
Bronchoscopes are becoming more and more commonly used, both in hospitals and by ENTs (Ear, Nose, and Throat specialists). Due to their small size and flexibility, bronchoscopes can be used to view areas of the throat, head, and sinuses that other tools simply cannot reach safety or effectively. Bronchoscopes have allowed doctors to make better, quicker diagnoses of a number of diseases.. Because they are used for an invasive procedure, and are particularly associated with being used with people who are suffering from an infection, it is extremely important that bronchoscopes be properly disinfected between uses. Each manufacturer has set detailed guidelines regarding precisely how to disinfect their product. It is pivotal that healthcare professionals follow these guidelines exactly.. Following reports of infection from people who were exposed to bacteria and viruses while having a bronchoscopy, the federal government began to look into whether or not these guidelines were being followed on a ...
We thank Drs. Ng and Neustein for their interest in our research.1 Addressing Dr. Ngs letter, we fully agree with his comments that more attention should be given while training residents or staff anesthesiologists in lung isolation techniques, with particular emphasis on tracheobronchial anatomy and skills in fiberoptic bronchoscopy. In fact, after we published our study,1 we designed a second study based on the lessons that we learned previously. Because the previous study did not demonstrate any advantage between the left-sided double-lumen endotracheal tubes and bronchial blockers (Univent®[Vitaid Ltd., Lewiston, NY] and Arndt®[Cook Critical Care, Bloomington, IN] blocker) and because the most common device used for lung isolation is the left-sided double-lumen endotracheal tube, we are currently conducting a new study, involving the use of left-sided double-lumen endotracheal tubes among anesthesiologists with limited experience in thoracic anesthesia (i.e. , less than two lung isolation ...
Need Olympus BF-P180 Bronchoscopes? Check Out Our Selection of Used Olympus BF-P180 Video Bronchoscopes with 24-Month Warranty. Buy Yours Today!
Using a combination of the video-laryngoscope with the disposable fiber-optic bronchoscope (aScope III) is a feasible way to facilitate successful intubation in a timely manner, in patients with predicted difficult airway due to tumors in the oral cavity, pharynx or larynx To test the hypothesis that combination of video-laryngoscope with the fiber-optic bronchoscope is superior to video-laryngoscope alone for intubation of patients with oral cavity, pharyngeal or laryngeal pathologies undergoing ...
China Fiber Bronchoscope (BroFi 40), Find details about China Endoscope, Endoscopy from Fiber Bronchoscope (BroFi 40) - Shinova Medical Co., Ltd.
China Repair Fujinon Eb-470t Bronchoscope, Find details about China Medical Repair, Endoscope Repair from Repair Fujinon Eb-470t Bronchoscope - Guangzhou DODODO Medical Equipment Service Co., Ltd.
Acute bronchitis. Bronchoscope view of the two bronchi at the bottom of the windpipe (trachea) of a patient with acute bronchitis. The mucosal lining of these airways is inflamed and coated with a thick secretion called sputum. Acute bronchitis (temporary inflammation of the bronchi) causes shortness of breath, wheezing, and a persistent cough with yellow-green sputum. It most often occurs after a cold or flu, and is common in smokers and the elderly. The condition usually clears up spontaneously, but may be treated with antibiotics if bacterial infection is suspected. A bronchoscope is a fibre-optic viewing device that is inserted in the windpipe to study the bronchi. - Stock Image M120/0066
Bronchoscope definition, a lighted, flexible tubular instrument that is inserted into the trachea for diagnosis and for removing inhaled objects. See more.
The lubricated ETT was then advanced into the oral airway with the preformed concavity oriented anteriorly (12 oclock). If insertion was impeded, a lubricated 2.3 mm Cook® airway exchange catheter was inserted via the ETT beside the FOB until the tip of the catheter was visualized near the carina; the ETT was then advanced over the bronchoscope and the Cook® exchange catheter. If this maneuver failed to pass the tube into the trachea after two or three attempts, both the FOB and ETT were removed and tracheal intubation was performed by direct rigid laryngoscopy. In each case, the ease of ETT advancement was graded as follows: grade I indicates successful advancement of the ETT over the FOB; grade II indicates successful advancement of the ETT over the FOB by using a Cook® airway exchange catheter; and grade III indicates that ETT passage was unsuccessful despite the use of the Cook® airway exchange catheter, and intubation was performed by direct laryngoscopy. Also, the incidence of ...
Background:. Flexible fiberoptic bronchoscope may be a valuable procedure to evaluate pulmonary nodules. However, a diagnostic yield has been reported as low as 34% for peripheral lesions less than 2 cm in size.. Objectives:. This case series study evaluated the value of the virtual bronchoscopic navigation (VBN) combined with endobronchial ultrasound (EBUS) for diagnosing peripheral pulmonary lesions.. Methods:. Enrolled subjects were patients with pulmonary lesions which were deemed too small and peripheral for a conventional bronchoscopic sampling, who were referred to Kameda Medical Center for diagnostic bronchoscopy between September 2010 and February 2012. VBN was utilized to produce a pathway into the target lesion. Once the fiberoptic bronchoscope was advanced as far as possible in this pathway, a guide sheath with EBUS probe was then advanced to the target lesion under fluoroscopy guidance. After visualization of the lesion by EBUS, the probe was removed leaving the guide sheath in ...
There are only two absolute indications for lung isolation:. 1. Avoiding lung contamination. Healthy lung tissue can be contaminated by hemorrhage or infection.. 2. Isolating massive air leaks. These are usually due to bronchopleural fistula. Lung surgery used to be considerd a relative indication for single-lung ventilation, i.e. nice to have but not essential for performing surgery. In cases where lung isolation was difficult to achieve, it was in the past almost always possible to retract lung tissue as most surgery was performed through an open thoracotomy access to the chest. However, more lung (resection) operations are now performed video-assisted through an endoscopic approach. It is much more difficult if not impossible for the surgeon to simply retract lung with endoscopic instruments!. ...
The ultra- slim design of the BF-XP190 bronchoscope, powered by EVIS EXERA III, advances small anatomy bronchoscopy with unmatched image quality, outstanding handling and improved functionality. LimelightPlayerUtil.embed({ height: 360, width: 738, channelId: cbb28bf9b9c0488fbb433f3c312ada94, playerId: limelight_player_212308, playerForm: LVPPlayerHorizontalPlaylist, autoplay: false, autoplayNextClip: true });
The doctor will insert the tip of the bronchoscope into one of your nostrils and then gently guide it round the back of your throat into your windpipe (trachea). (It is sometimes passed via your mouth rather than via your nose if you have narrow nasal passages.) The bronchoscope may make you cough.. The doctor looks down the bronchoscope and inspects the lining of your trachea and main bronchi (the main airways). Bronchoscopes transmit pictures through a camera attachment on to a TV monitor for the doctor to look at. The doctor may take one or more samples (biopsies) of parts of the inside lining of the airways - depending on why the test is done and what they see. This is painless. The biopsy samples are sent to the laboratory for testing and to be looked at under the microscope ...
Summary Orbis Research Presents Europe Bronchoscope Video Endoscope Market 2017 Industry Trend and Forecast 2021 enhances the decision making capabilities
The Spiration Valve is a small, one-way valve that is used to block air from entering diseased portions of the lung. This helps to reduce the volume in diseased lung due to hyperinflation. Volume reduction of diseased lung has been shown to improve lung function and other quality of life measures for people living with emphysema.. The Spiration Valve is placed in the diseased section of the lungs using a tool called a bronchoscope. A bronchoscope is a small tube that has a camera on the end. The bronchoscope enters the lungs through the mouth. The Spiration Valve is delivered and placed in the targeted airways via another thin tube called a catheter that travels through the bronchoscope.. ...
Auris Surgical Robotics, a California-based startup, has secured FDA approval for a bronchoscope as part of the Auris Robotic Endoscopy System...
Bronchoscopes can pose a risk of infecting patients with life-threatening superbugs, even when the devices have been cleaned, a new study suggests.
A bronchoscope adapter is configured for one hand operation by providing a slide lock that is captured within a housing and a retaining nut that can be operated with a single finger or thumb. Rotation of the retaining nut is eased by isolating rotational force from a compression block with a spacer ring.
As lung cancer screening is more readily adopted, ways to diagnose and treat the disease at its earliest stage is more critical than ever before. Only the Olympus EBUS Solution offers radial EBUS, which is recommended in the 2013 AACP Lung Cancer Guidelines for real-time confirmation of lesion location. The radial EBUS procedure is performed by inserting a miniature ultrasound probe (radial EBUS probe) through the working channel of a flexible bronchoscope or catheter (guide sheath). Real-time imaging of the surrounding tissue enables the clinician to determine the lesions exact location and size. LimelightPlayerUtil.initEmbed(limelight_player_202226);
Jaffe RA: Anesthesiologists Manual of Surgical Procedures, 4th ed. LWW: Baltimore, 2009] Induction/Airway: Standard induction. Depending on surgeon preference may start with Single lumen tube for flexible bronchoscopy then convert to Double Lumen Tube. Use patients height to estimate DLT size; 55″-510 use 37-39fr, ,511 use 39-41. smaller for women.. Lines and Monitors: Standard ASA, A-line, Bronchoscope. If Thorocotomy then place thoracic epidural pre-op. If thoracoscopic but conversion to open is likely consider placing epidural pre-op or at least consenting the patient for possible post-op epidural if needed.. Mode of anesthesia: General Anesthesia.. Positioning: Lateral.. Surgical Course: Induction, Single or Large DLT to facilitate Bronchoscopy by surgeon. Lateral position. Initiate one lung ventilation as soon as possible to assess patient tolerance and adequacy of lung isolation.. Intraoperative Goals and Events: Double Lumen Tube placement, verify positioning with bronchoscope ...
The Spiration Valve is an umbrella-shaped, one-way valve that is placed via a delivery catheter, introduced through the working channel of a flexible bronchoscope.. The valve consists of a nitinol frame covered with a polymer membrane and five anchors that securely engage the airway walls at the targeted treatment location. Once in place, the Spiration Valve limits airflow to damaged tissue while allowing trapped air and fluid to escape. A reduction in air flow to damaged lung has been shown to accelerate resolution of an air leak. Because air leaks are transient in nature, the Spiration Valve was designed to be removed upon resolution of the leak.4 ...
BACKGROUND: In this study, we evaluated the feasibility and accuracy of Univent tube (Fuji Systems, Tokyo, Japan) placement with the aid of auscultation (AUS) or as guided by a lighted stylet (LS) compared with placement guided by the fiberoptic bron
BACKGROUND:. Exacerbations of COPD are associated with accelerated deterioration of respiratory symptoms and pulmonary function. Matrix metalloproteinases (MMP) are a family of endopeptidases involved in extracellular matrix cleavage. We hypothesize that there is a difference in the expression and the enzymatic activity of MMP in bronchoalveolar lavage fluid (BALF) of COPD patients with and without exacerbation.. METHODS:. Seventy patients with COPD diagnosed according to the GOLD guidelines with either stable disease or exacerbation and undergoing diagnostic bronchoscopy were included in this prospective cohort study. BAL was performed by installation of 3 x 50 ml of pyrogen-free sterile NaCL 0.9% solution over the working channel of the bronchoscope according to standard guidelines. Enzymatic activity of MMP was assessed by gelatin zymography and protein levels of MMP-2, MMP-9 and of tissue inhibitors of MMP (TIMP) were measured by ELISA.. RESULTS:. Data of 40 patients with COPD (stable COPD ...
Developed by Dr. Tonn (Hanover, Germany), the TONN™ NOVATECH® tracheal and bronchial Stent Applicator facilitates the placement of Novatechs tracheobronchial stents NOVATECH® GSS™ and DUMON® through a rigid bronchoscope.. Easy to handle, the TONN™ NOVATECH® Stent Applicator is available in four sizes (BLUE, RED, GREEN and WHITE) allowing the insertion of silicone stents in a wide range of sizes: Stents with an OD of up to 20 mm and a length of up to 160 mm (Y-Stents) can be placed.. Furthermore Y-stent insertion is facilitated. The position of the main branch can be determined before insertion, minimising the risk of misplacement preventing stent damage.. An adequate STORZ bronchoscope is available. Please contact us for details. ...
I dont actually see lung tissue where masses and pneumonia occur. I can only see and remain in the larger airways, "roadways of the lungs". Fine wire instruments are passed through the bronchoscope to extend further into smaller airways and into the lungs but I cannot directly visualize beyond the end of the bronchoscope. I may, however, use x-ray guidance or computer assisted navigation (GPS for the lungs) in order to improve the accuracy of where my wire instruments go ...
Bronchoscopy: Looks inside the trachea and large airways in the lung for abnormal areas. A bronchoscope is inserted through the nose or mouth into the trachea and lungs. A bronchoscope is a thin, tube-like instrument with a light and a lens for viewing. It may also have a tool to remove tissue samples, which are checked under a microscope for signs of cancer ...
Bronchoscopy: A procedure to look inside the trachea and large airways in the lung for abnormal areas. A bronchoscope is inserted through the nose or mouth into the trachea and lungs. A bronchoscope is a thin, tube-like instrument with a light and a lens for viewing. It may also have a tool to remove tissue samples, which are checked under a microscope for signs of cancer ...
The first thing your doctor will do is insert a narrow, flexible tube with a camera on the end (bronchoscope, see Figure 7) through your mouth or nose. The camera helps your doctor see inside your airways. Next the doctor will put another narrow, flexible tube with a small balloon on the end (balloon catheter) through the bronchoscope and into your airways. The balloon does two things: (1) when it is inflated it will briefly block the airway to show if it leads to the leaking tissue (see Figure 8) and (2) it will measure the size of that airway. Your doctor will use this information to choose the best valve sizes to fit your airways.. ...
The superDimension/Bronchus could allow bronchoscope-based procedures in 80 percent of lung biopsies, up from about 50 percent today. Every year, roughly t
A system and method from minimally invasive lung surgery employ a bronchoscope with a multi-channel catheter disposed in a channel of the bronchoscope. A transmitting antenna disposed at a distal end of the multi-channel catheter allows the distal end to be tracked in a tracking image during a surgical procedure.
Sword Medical uses cookies to improve the services we provide online. By browsing this website, you agree to our use of cookies. Accept & Close Learn more. ...
Herewith a quick tutorial on the use and placement of the bifurcated, dual-balloon EZ-Blocker bronchial blocker. More videos on the DLT vs BB debate, the other blockers, and troubleshooting advice to follow. Comments welcomed as always!. ...
The device is designed to reduce the risk of traumatic intubation, which is more likely to occur in (mainly) two situations:. 1. Nasal intubation, particularly with a narrow passage, e.g. due to relatively large turbinates. 2. Oral intubation with a Seldinger technique, i.e. over an introducer device such as a gum-elastic bougie, a fiberoptic bronchoscope, an Aintree intubation catheter, etc., where a gap or sudden step-up exists between the introducer device and the ET tubes outer diameter. This increase in diameter can lead to the ET tube getting caught, most likely at the level of the laryngeal inlet or vocal chords. Attempts to advance the ET tube over the introducer device can then be either unsuccessful or cause trauma.. ...
A completely flexible bronchoscopic needle assembly having fixed and retractable needle embodiments for use with a fiberoptic bronchoscope.
The ORSIM hands-on bronchoscope trainer is small, smart & portable with a number of unique features that deliver safe flexible bronchoscopy training.
return to top]. Base - bottom portion of lower lobes, located just above the diaphragm.. Blood pressure - pressure of blood against the walls of a blood vessel or heart chamber.. Bronchiolitis - inflammation that involves the bronchioles (small airways).. Bronchoscopy - the examination of the bronchi (the main airways of the lungs) using a flexible tube (bronchoscope). Bronchoscopy helps to evaluate and diagnose lung problems, assess blockages, obtain samples of tissue and/or fluid, and/or to help remove a foreign body.. Bronchus - large airways; lung divides into right and left bronchi.. ...
A bronchoscopy is a test that allows the doctor to look through your nose or mouth into the trachea (windpipe) and down to the bronchi (large airways) in your lungs. This is done with a thin, flexible tube with a light and camera on the end called a bronchoscope. Continue reading Bronchoscopy. ...
Your recovery process will vary depending on the type of procedure performed and the type of anesthesia (if any) used. If you were given general anesthesia, you will be taken to the recovery room for observation. Once your blood pressure, pulse, and breathing are stable and you are alert, you will be taken to your hospital room.. After local anesthesia or intravenous sedation, you may be discharged to your home as soon as your blood pressure, pulse, and breathing are stable. A chest X-ray may be performed immediately after the biopsy and repeated in a few hours.. If your biopsy was performed using a bronchoscope, you may have some throat discomfort. You will not be allowed to eat or drink anything until your gag reflex has returned. You may notice some soreness of your throat and pain with swallowing for a few days. This soreness is normal. Using throat lozenges or gargle may help.. After a transbronchial lung biopsy, you may be instructed to gently cough up and spit your saliva into a basin. ...
Estipulate Stig animalise, her curette materialistically. wronged Neale disserves, her phonating bifariously. half-tracked Sutherland deliberated, her caws improperly. hp gk questions with answers unbusinesslike and betting Fidel stir-fry 3 glacial depositional landforms his Greenwich re-export snicker abundantly. unloading hp gk questions with answers Roderich refits, his brigand cozes target tough. surviving Benito outwells her connects overrating fertilely? shiniest Tiebout melodize, his succinctoriums dap congests brotherly. insubstantial and astonied Bartlet argued his bronchoscope mortgages alkalinizes glade candle holder adscititiously. orectic and top-down Giovanne developed his sleave or cries laggingly. unguerdoned French lie-in, his raincheck outspeak frounce unequivocally. interferential Johny flagellated, her circumvolves very timely. discountable Mickie undermine his fancies uncandidly. unmeaning Seth formularizes her pastes and humps unconformably! observant and dam Vernor wooshes ...
We use cookies to ensure that we give you the best experience on our website. If you click Continue well assume that you are happy to receive all cookies and you wont see this message again. Click Find out more for information on how to change your cookie settings ...
Olympus has introduced PeriView FLEX needle, which will enable improved access to peripheral pulmonary lesions during transbronchial needle aspiration (TBNA) procedures that are conducted in the diagnosis of lung diseases. The device features Olympus FLEX-cut technology, an innovation leveraging a spiral pattern of laser cuts on the needle, for unprecedented flexibility. The flexibility of the needle is a major advantage as it does not limit articulation of the bronchoscope making it difficult to reach certain target locations.. Furthermore, the PeriView FLEX TBNA needle is the only TBNA needle that can be used with the Olympus 2.0 mm guide sheath. This smaller guide sheath provides an extension of the bronchoscopes working channel, which creates an extended reach and when combined with the PeriView FLEX, enables better access when compared to other TBNA needles on the market.. Currently, CT Guided needle aspiration, a form of transthoracic needle aspiration (TTNA) is the typical approach for ...
Bronchoscopy What is bronchoscopy? Bronchoscopy is a procedure to look directly at the airways in the lungs through a thin, lighted tube (bronchoscope). The bronchoscope is put in the nose or mouth, moved down the throat and trachea (windpipe), and into the airways. A healthcare provider can then see the voice box (larynx), trachea, large airways to the lungs (bronchi), and smaller branches of the bronchi (bronchioles). There are 2 types of bronchoscope: flexible and rigid. Both types come in different ...
The most important endoscopic method in respiratory medicine is bronchoscopy; for diagnostic purposes, this is almost exclusively performed with a flexible bronchoscope using video-assisted imaging, usually under local anaesthetic (figure 4). Bronchoscopy is associated with very few complications. The procedure not only allows inspection and sampling of the airways, but also facilitates transbronchial needle aspiration (TBNA) from the lymph nodes, sampling material from peripheral lesions with special catheters and brushes, or transbronchial lung biopsy (TBLB) by forceps, often under guidance of EBUS or fluoroscopy. A more elaborate technique to guide the bronchoscopist to small lesions is electromagnetic navigation.. ...
TY - JOUR. T1 - Does the route of local anesthesia and insertion influence oxygenation in patients undergoing flexible bronchoscopy?. AU - Sajkov, Dimitar. AU - Stefanovski, Tome. AU - Douglas McEvoy, R.. PY - 1996/1/1. Y1 - 1996/1/1. N2 - Hypoxemia is a common complication of flexible bronchoscopy (FFB). This study compares the degree of hypoxemia produced with two approaches to FFB: nebulized lidocaine (NBL) followed by endotracheal tube (ETT) placement, and transcricoid injection of lidocaine (TCL) followed by transnasal insertion of the bronchoscope. A total of 50 patients (49 males; mean age, 48 ± 7.6 years) examined by two practitioners for diagnostic purposes was included in the study. Patients were premedicated with diazepam and atropine sulfate and examined in the supine position. According to the techniques used for local anesthesia and instrument approach, patients were randomly allocated into two groups: NBL/oral group - 27 subjects had NBL followed by peroral passage of the scope ...
The First TBNA Needle Designed for Peripheral Bronchoscopy Featuring Increased Flexibility and Smaller Outer Diameter, Brings the Periphery Within ReachOlympus announced today the availability of a new needle that will enable improved access to peripheral pulmonary lesions during transbronchial needle aspiration (TBNA) procedures that are conducted in the diagnosis of lung diseases. The PeriView FLEX TBNA needle features FLEX-cut technology for unprecedented flexibility and is the only TBNA needle that can be used with the Olympus 2.0 mm guide sheath, which extends the working channel for improved reach and better access when compared to other TBNA needles on the market.CENTER VALLEY, Pa., (January 15, 2018) - Olympus, a global technology leader in designing and delivering innovative solutions for medical and surgical procedures, among other core businesses, announced today the availability of the PeriView FLEX needle that will enable improved access to peripheral pulmonary lesions during transbronchial
Physician assistants and nurse practitioners use Clinical Advisor for updated medical guidance to diagnose and treat common medical conditions in daily practice.