The blood supply of the lateral epiphyseal arteries in Perthes' disease. (57/2159)

We performed superselective angiography in 28 hips in 25 patients with Perthes' disease in order to study the blood supply of the lateral epiphyseal arteries (LEAs). Interruption of the LEAs at their origin was observed in 19 hips (68%). Revascularisation in the form of numerous small arteries was seen in ten out of 11 hips in the initial stage of Perthes' disease, in seven of eight in the fragmentation stage and in five of nine in the healing stage. Penetration of mature arteries into the depths of the epiphysis was seen in four of nine hips in the healing stage. Vascular penetration was absent in the weight-bearing portion of the femoral head below the acetabular roof. Interruption of the posterior column artery was seen where it passed through the capsule in seven hips when they lay either in internal rotation or in abduction with internal rotation. We suggest that in Perthes' disease the blood supply of the LEAs is impaired at their origin and that revascularisation occurs from this site by ingrowth of small vessels into the femoral epiphysis. This process may be the result of recurrent ischaemic episodes.  (+info)

The depressor function of biceps on the head of the humerus in shoulders with tears of the rotator cuff. (58/2159)

We investigated the function of biceps in 18 patients (19 shoulders) with lesions of the rotator cuff. Their mean age was 59 years. Another series of 18 patients (19 shoulders) with normal rotator cuffs as seen on MRI acted as a control group. Their mean age was 55 years. A brace was used to maintain contraction of biceps during elevation. Anteroposterior radiographs were obtained with the arm elevated at 0 degrees , 45 degrees and 90 degrees with and without contraction of biceps. The distance between the centre of the head of the humerus and the glenoid was compared in the two groups. We found that in the group with tears there was significantly greater proximal migration of the head of the humerus at 0 degrees and 45 degrees of elevation without contraction of biceps but depression of the head of the humerus at 0 degrees, 45 degrees and 90 degrees when biceps was functioning. We conclude that biceps is an active depressor of the head of the humerus in shoulders with lesions of the rotator cuff.  (+info)

Autologous morsellised bone grafting restores uncontained femoral bone defects in knee arthroplasty. An in vivo study in horses. (59/2159)

The properties of impacted morsellised bone graft (MBG) in revision total knee arthroplasty (TKA) were studied in 12 horses. The left hind metatarsophalangeal joint was replaced by a human TKA. The horses were then randomly divided into graft and control groups. In the graft group, a unicondylar, lateral uncontained defect was created in the third metatarsal bone and reconstructed using autologous MBG before cementing the TKA. In the control group, a cemented TKA was implanted without the bone resection and grafting procedure. After four to eight months, the animals were killed and a biomechanical loading test was performed with a cyclic load equivalent to the horse's body-weight to study mechanical stability. After removal of the prosthesis, the distal third metatarsal bone was studied radiologically, histologically and by quantitative and micro CT. Biomechanical testing showed that the differences in deformation between the graft and the control condyles were not significant for either elastic or time-dependent deformations. The differences in bone mineral density (BMD) between the graft and the control condyles were not significant. The BMD of the MBG was significantly lower than that in the other regions in the same limb. Micro CT showed a significant difference in the degree of anisotropy between the graft and host bone, even although the structure of the area of the MBG had trabecular orientation in the direction of the axial load. Histological analysis revealed that all the grafts were revascularised and completely incorporated into a new trabecular structure with few or no remnants of graft. Our study provides a basis for the clinical application of this technique with MBG in revision TKA.  (+info)

Changes in the loads on an internal spinal fixator after iliac-crest autograft. (60/2159)

Spines are often stabilised posteriorly by internal fixation and anteriorly by a bone graft. The effect of an autologous bone graft from the iliac crest on implant loads is unknown. We used an internal spinal fixation device with telemetry to measure implant loads for several body positions and activities in nine patients before and after anterior interbody fusion. With the body upright, implant loads were often higher after than before fusion using a bone graft. Distraction of the bridged region led to high implant loads in patients with a fractured vertebra and to marked changes in load in those with degenerative instability. Leaving the lower of the bridged intervertebral discs intact led to only small changes in fixator load after anterior interbody fusion. A bone graft alone does not guarantee a reduction of implant loads.  (+info)

Macro and microscopic examination of the ruptured surfaces of anterior cruciate ligaments of rabbits. (61/2159)

In a study combining tissue mechanics and fracture morphology for the first time, we examined the ruptured surfaces of anterior cruciate ligaments of rabbits and related their appearance to the initial loading conditions. Sixteen specimens were stretched to failure at rates of displacement of 10 and 500 mm/min. We used video images to study the changes which occurred during the fracture process and SEM to examine the appearance of the ruptured surfaces. The surfaces of ligaments tested at 10 mm/min had more pulled-out collagen fibres and the fibres had more pronounced waviness compared with those tested at 500 mm/min. We have shown that the macroscopic appearance of ruptured ligaments can be related to their microscopic appearance and that it is possible to deduce whether failure was by gradual tearing of the fibres or catastrophic failure.  (+info)

Load-displacement properties of the normal and injured lower cervical spine in vitro. (62/2159)

The objective of this study was to determine which discoligamentous structures of the lower cervical spine provide significant stability with regard to different loading conditions. Accordingly, the load-displacement properties of the normal and injured lower cervical spine were tested in vitro. Four artificially created stages of increasing discoligamentous instability of the segment C5/6 were compared to the normal C5/6 segment. Six fresh human cadaver spine segments C4-C7 were tested in flexion/extension, axial rotation, and lateral bending using pure moments of +/- 2.5 Nm without axial preload. Five conditions were investigated consecutively: (1) the intact functional spinal unit (FSU) C5/6; (2) the FSU C5/6 with the anterior longitudinal ligament and the intertransverse ligaments sectioned; (3) the FSU C5/6 with an additional 10-mm-deep incision of the anterior half of the anulus fibrosus and the disc; (4) the FSU C5/6 with additionally sectioned ligamenta flava as well as interspinous and supraspinous ligaments; (5) the FSU C5/6 with additional capsulotomy of the facet joints. In flexion/extension, significant differences were observed concerning range of motion (ROM) and neutral zone (NZ) for all four stages of instability compared to the intact FSU. In axial rotation, only the stage 4 instability showed a significantly increased ROM and NZ compared to the intact FSU. For lateral bending, no significant differences were observed. Based on these data, we conclude that flexion/extension is the most sensitive load-direction for the tested discoligamentous instabilities.  (+info)

In vivo regulation of the beta-myosin heavy chain gene in soleus muscle of suspended and weight-bearing rats. (63/2159)

In the weight-bearing hindlimb soleus muscle of the rat, approximately 90% of muscle fibers express the beta-myosin heavy chain (beta-MHC) isoform protein. Hindlimb suspension (HS) causes the MHC isoform population to shift from beta toward the fast MHC isoforms. Our aim was to establish a model to test the hypothesis that this shift in expression is transcriptionally regulated through specific cis elements of the beta-MHC promoter. With the use of a direct gene transfer approach, we determined the activity of different length beta-MHC promoter fragments, linked to a firefly luciferase reporter gene, in soleus muscle of control and HS rats. In weight-bearing rats, the relative luciferase activity of the longest beta-promoter fragment (-3500 bp) was threefold higher than the shorter promoter constructs, which suggests that an enhancer sequence is present in the upstream promoter region. After 1 wk of HS, the reporter activities of the -3500-, -914-, and -408-bp promoter constructs were significantly reduced ( approximately 40%), compared with the control muscles. However, using the -215-bp construct, no differences in promoter activity were observed between HS and control muscles, which indicates that the response to HS in the rodent appears to be regulated within the -408 and -215 bp of the promoter.  (+info)

Complement activation promotes muscle inflammation during modified muscle use. (64/2159)

Modified muscle use can result in muscle inflammation that is triggered by unidentified events. In the present investigation, we tested whether the activation of the complement system is a component of muscle inflammation that results from changes in muscle loading. Modified rat hindlimb muscle loading was achieved by removing weight-bearing from the hindlimbs for 10 days followed by reloading through normal ambulation. Experimental animals were injected with the recombinant, soluble complement receptor sCR1 to inhibit complement activation. Assays for complement C4 or factor B in sera showed that sCR1 produced large reductions in the capacity for activation of the complement system through both the classical and alternative pathways. Analysis of complement C4 concentration in serum in untreated animals showed that the classical pathway was activated during the first 2 hours of reloading. Analysis of factor B concentration in untreated animals showed activation of the alternative pathway at 6 hours of reloading. Administration of sCR1 significantly attenuated the invasion of neutrophils (-49%) and ED1(+) macrophages (-52%) that occurred in nontreated animals after 6 hours of reloading. The presence of sCR1 also reduced significantly the degree of edema by 22% as compared to untreated animals. Together, these data show that increased muscle loading activated the complement system which then briefly contributes to the early recruitment of inflammatory cells during modified muscle loading.  (+info)