The effect of tourniquet padding on the efficiency of tourniquets of the upper limb. (57/238)

We report the effect of padding on the efficiency of the pneumatic tourniquet for the upper limb. Varying thicknesses of two commercially-available types of orthopaedic padding (Cellona and Velband) were applied to the arms of 20 volunteers, with three pressure transducers placed directly beneath the padding. A tourniquet was positioned over the padding and inflated to 220 mmHg. Significant reductions in the transmitted pressure were recorded from the transducers with both padding materials. With eight layers of padding, reductions in pressure of 13% (1% to 26%) and 18% (7% to 35%) were seen with Cellona and Velband, respectively. The reduction in pressure with Velband padding correlated with increasing arm circumference (Pearson's correlation coefficient 0.711, p < 0.001). Studies to date have examined how arm circumference affects the required tourniquet inflation pressure. Our study is the first to investigate the effect of the padding and the findings suggest that using more than two layers results in a significant reduction in the transmitted pressure.  (+info)

Pharmacokinetics/pharmacodynamics analysis of the relationship between the in vivo micturition pressure and receptor occupancy of (R)-oxybutynin and its metabolite in rats. (58/238)

To elucidate the relationships between the pharmacokinetics and pharmacological effects of oxybutynin ((R/S)-OXY), the micturition pressure and the plasma concentration profiles of (R)-OXY and (R)-N-desethyloxybutynin ((R)-DEOB), a pharmacologically active metabolite, after administration by three different routes (i.v., p.o. and transdermal) in rats were measured and analyzed using an inhibitory effect E(max) model with their in vitro pharmacological effects. The plasma exposure ratios of (R)-DEOB to (R)-OXY calculated from the AUCs were somewhat different among the routes administered. (R)-OXY and (R)-DEOB equally inhibited the acetylcholine-induced contractions in vitro. The micturition pressure, measured using the cystometric method in vivo, exhibited saturation against the dose administered. The inhibitory effect E(max) model well described the relationship between the micturition pressure and the receptor occupancy calculated from the plasma concentrations and pA(2) values and resulted in an extremely small receptor occupancy (0.206%) to exhibit half of the maximum effect. The estimated receptor occupancy profiles suggested a sufficient and long-lasting receptor occupation after transdermal administration of (R/S)-OXY, while the receptor occupancy diminished rapidly after the i.v. and p.o. administration. These data indicate that transdermal administration of (R/S)-OXY would be useful to achieve suitable pharmacological effects without excess plasma concentrations.  (+info)

Comparison of incremental and constant load tests of inspiratory muscle endurance in COPD. (59/238)

The aim of the present study was to determine the relative value of incremental and constant load tests in detecting changes in inspiratory muscle endurance following high-intensity inspiratory muscle training (H-IMT) in chronic obstructive pulmonary disease. In total, 16 subjects (11 males; forced expiratory volume in one second (FEV(1)) 37.4+/-12.5%) underwent H-IMT. In addition, 17 subjects (11 males; FEV(1) 36.5+/-11.5%) underwent sham inspiratory muscle training (S-IMT). Training took place three times a week for 8 weeks. Baseline and post-training measurements were obtained of maximum threshold pressure sustained during an incremental load test (P(th,max)) and time breathing against a constant load (t(lim)). Breathing pattern was unconstrained. H-IMT increased P(th,max) and t(lim) relative to baseline and to any change seen following S-IMT. The effect size for P(th,max) was greater than for t(lim). Post-training tests were accompanied by changes in breathing pattern, including decreased duty cycle, which may have served to decrease inspiratory work and thereby contribute to the increase in P(th,max) and t(lim) in both groups. When assessing inspiratory muscle function in chronic obstructive pulmonary disease via tests in which the pattern of breathing is unconstrained, the current authors recommend incremental load tests be used in preference to constant load tests. However, to attribute changes in these tests to improvements in inspiratory muscle endurance, breathing pattern should be controlled.  (+info)

A portable tactile sensory diagnostic device. (60/238)

Current methods for applying multi-site vibratory stimuli to the skin typically involve the use of two separate vibrotactile stimulators, which can lead to difficulty with positioning of stimuli and in ensuring that stimuli are delivered perfectly in phase at the same amplitude and frequency. Previously, we reported a two-point stimulator (TPS) that was developed in order to solve the problem of delivering two-point stimuli to the skin at variable distances between the sites of stimulation. Because of the success of the TPS, we designed and fabricated a new stimulator with four significant improvements over our original device. First, the device is portable, lightweight and can be used in a variety of non-laboratory settings. Second, the device consists of two independently controlled stimulators which allow delivery of stimuli simultaneously to two distinct skin sites with different amplitude, frequency and/or phase. Third, the device automatically detects the skin surface and thus allows for much better automated control of stimulus delivery. Fourth, the device is designed for rapid manufacture and, therefore, can be made readily available to other research (non-laboratory) settings. To demonstrate the device, a modified Bekesy tracking method was used to evaluate the simultaneous amplitude discrimination capacity of 20 subjects.  (+info)

Endoleaks after endovascular aneurysm repair lead to nonuniform intra-aneurysm sac pressure. (61/238)

OBJECTIVE: This was a study of intra-aneurysm sac pressures in patients who presented with endoleaks after endovascular repair (EVAR) of abdominal aortic aneurysms (AAA). METHODS: Twenty-five patients (18 men, 7 women) with endoleaks, age (IQR 68 to 80), underwent 31 direct intra-aneurysm sac pressure measurements, DISP at 16 months after EVAR (IQR, 14 to 26 months). Diameter of AAA was 59 mm (IQR, 52 to 67 mm). Six patients underwent DISP twice. Tip-pressure sensors were used through direct translumbar puncture of the AAA except in three patients (transabdominal puncture in 2; endoluminal in 1). Mean pressure index (MPI) was calculated between simultaneously registered intra-aneurysm sac and systemic pressures. Values presented are medians with interquartile range (IQR). RESULTS: Type I endoleaks (n = 1) showed MPI of 93% in the nidus and 62% in the thrombus. Type II endoleaks were associated with lower MPIs in the thrombus (35%; IQR 24% to 38%) when AAAs shrank (n = 4) compared with when the AAAs remained unchanged (n = 11; MPI, 78%; IQR, 47% to 85%) or expanded (n = 6; MPI, 74%; IQR, 58% to 87%; P = .019). The nidus of type II endoleaks (MPI, 79%; IQR, 70% to 90%) had higher pressure than the thrombus (45%, IQR, 34% to 85%; P = .047; n = 7). Successful embolization of type II endoleaks led to AAA shrinkage (n = 3; MPI reduction, 13% to 31%) or diameter stability (n = 3; unchanged MPIs, 37% to 44%). Type III endoleaks (n = 3) had MPIs in the thrombus of 33% to 70%. CONCLUSIONS: Endoleaks after EVAR pressurize the AAA sac nonuniformly, with higher, near-systemic, pressure in the endoleak nidus compared with the thrombus. Nevertheless, type II endoleaks in shrinking AAAs have lower intra-sac pressure than expanding or stable aneurysms, and successful endoleak embolization reduces pressure.  (+info)

Oscillatory pressure wave transmission from the upper airway to the carotid artery. (62/238)

Snoring-associated vibration energy transmission from the upper airway to the carotid artery has been hypothesized as a potential atherosclerotic plaque initiating/rupturing event that may provide a pathogenic mechanism linking snoring and embolic stroke. We examined transmission of oscillatory pressure waves from the pharyngeal lumen to the common carotid artery wall and lumen in seven male, anesthetized, spontaneously breathing New Zealand White rabbits. Airflow was monitored via a pneumotachograph inserted in series in the intact trachea. Fifteen 20-s runs of, separately, 40-, 60-, and 90-Hz oscillatory pressure waves [pressure amplitude in the trachea (Ptr(amp)), amplitude 2-20 cmH(2)O] were generated by a loudspeaker driven by a sine wave generator and amplifier and superimposed on tidal breathing via the cranial tracheal connector. Pressure transducer-tipped catheters measured pressure amplitudes in the tissues adjacent to the common carotid artery bifurcation (Pcti(amp)) and within the lumen (carotid sinus; Pcs(amp)). Data were analyzed using power spectrum analysis and linear mixed-effects statistical modeling. Both the frequency (f) and amplitude of the injected pressure wave influenced Pcti(amp) and Pcs(amp), in that ln Pcti(amp) = 1.2(Ptr(amp)) + 0.02(f) - 5.2, and ln Pcs(amp) = 0.6(Ptr(amp)) + 0.02(f) - 4.9 (both P < 0.05). Across all frequencies tested, transfer of oscillatory pressure across the carotid artery wall was associated with an amplitude gain, as expressed by a Pcs(amp)-to-Pcti(amp) ratio of 1.8 +/- 0.3 (n = 6). Our findings confirm transmission of oscillatory pressure waves from the upper airway lumen to the peripharyngeal tissues and across the carotid artery wall to the lumen. Further studies are required to establish the role of this incident energy in the pathogenesis of carotid artery vascular disease.  (+info)

Infants with bronchopulmonary dysplasia suckle with weak pressures to maintain breathing during feeding. (63/238)

OBJECTIVE: Preterm infants with bronchopulmonary dysplasia often demonstrate sucking difficulties. The aim of this study was to determine whether the severity of bronchopulmonary dysplasia affects not only coordination among suck-swallow-respiration but also sucking endurance and performance itself. PATIENTS AND METHODS: Twenty very low birth weight infants were studied. Infants with anomalies or intraventricular hemorrhage were excluded from the evaluation. Subjects were divided into 3 groups: no bronchopulmonary dysplasia (7 infants), bronchopulmonary dysplasia without home oxygen therapy (7 infants), and bronchopulmonary dysplasia with home oxygen therapy (6 infants). In addition to sucking efficiency, pressure, frequency, duration, and duration of sucking burst, length of deglutition apnea, number of swallows per burst, and respiratory rate were also measured during bottle-feeding at 40 weeks' postmenstrual age. In addition, PCO2 and oxygen saturation were measured at rest and during bottle-feeding. RESULTS: Infants with severe bronchopulmonary dysplasia demonstrated not only the lowest sucking pressure and sucking frequency, shortest sucking burst duration, and lowest feeding efficiency but also the lowest frequency of swallows during the run and the longest deglutition apnea. The respiratory rate was highest, and the decrease in oxygen saturation was largest, in infants with severe bronchopulmonary dysplasia. CONCLUSIONS: Feeding problems depend on the severity of bronchopulmonary dysplasia. Infants with bronchopulmonary dysplasia demonstrated not only poor feeding coordination but also poor feeding endurance and performance.  (+info)

Evaluation of pressure transmission and intra-aneurysmal contents after endovascular repair using the Trivascular Enovus expanded polytetrafluoroethylene stent graft in a canine model of abdominal aortic aneurysm. (64/238)

OBJECTIVE: Endotension has been defined as persistently increased pressure within the excluded sac of an abdominal aortic aneurysm (AAA) resulting in increasing aneurysm size after endovascular repair in the absence of endoleak. Devices that use expanded polytetrafluoroethylene (ePTFE) have been associated with the development of endotension and continued AAA enlargement. In this study, intra-aneurysmal pressure and aneurysm content were evaluated after endovascular repair with the Enovus ePTFE stent graft in a canine model. METHODS: Prosthetic ePTFE aneurysms, each containing a solid-state, strain-gauge pressure transducer, were implanted in the infrarenal aorta of 13 mongrel dogs (25-35 kg). A second pressure transducer was inserted into the native aorta for systemic arterial pressure measurement. The stent graft was then deployed to exclude the aneurysm via distal aortic access. Comparison was made among three distinct stent grafts: the Trivascular Enovus (nonporous ePTFE; four animals), the original Gore Excluder (porous ePTFE; five animals), and the Medtronic AneuRx (Dacron; four animals). Daily systemic and intra-AAA pressures were measured for 4 weeks. Intra-aneurysmal pressures were indexed to simultaneously measured systemic pressures. After 4 weeks, the aorta, the prosthetic aneurysm, and its contents were harvested, photographed, and processed for histologic investigation with hematoxylin and eosin and Masson trichrome staining. RESULTS: Within 24 hours after exclusion, the mean arterial pressure and pulse pressure within the AAA sac tapered to less than 20% of systemic pressure for all three stent graft types. Throughout the postoperative period, significantly lower indexed intra-aneurysmal pressures were present in the Enovus- and AneuRx-treated aneurysms as compared with those treated with the original Excluder stent graft (0.05 +/- 0.04, 0.16 +/- 0.06, and 0.06 +/- 0.03 for the Enovus, Excluder, and AneuRx, respectively). Histologic analysis of the Enovus-treated aneurysms demonstrated intraluminal content characterized almost entirely by erythrocytes and infrequent white blood cells without the fibrin organization-characteristics of acute or chronic thrombus. This contrasted with the content of the Excluder-treated aneurysms, which contained poorly organized fibrin deposition suggestive of acute thrombus, and of the AneuRx-treated aneurysms, which demonstrated mature, well-organized collagenous connective tissue. CONCLUSIONS: Exclusion of the AAA with the Enovus stent graft resulted in nearly complete elimination of intra-aneurysmal pressure in this model. Histologic analysis of the aneurysm content further suggested complete exclusion, including elimination of circulating clotting factors and fibroblasts responsible for thrombus formation and reorganization. Ultimately, clinical evaluation will be necessary to demonstrate the effectiveness of this stent graft in preventing the development of endotension.  (+info)