Intracranial arteriovenous malformations. Observations after experience with computerised tomography. (9/28924)

Thirty-six patients with angiographically confirmed intracranial arteriovenous malformations have had computerised tomographic scans performed as part of their investigation. This study demonstrates the incidence of haematoma formation after haemorrhage, the frequency of calcification not visible on plain radiographs, and describes the possible causes for a complicating hydrocephalus. Further information has been gained from the intravenous injection of sodium iothalamate (Conray 420), with comparison of the scans taken before and after the injection.  (+info)

Computerised tomography and intellectual impairment in the elderly. (10/28924)

Sixty-six elderly subjects (mean age 77 years) whose mental state was assessed clinically and by simple psychometric tests have been studied by computerised tomography. The mean maximum ventricular area in the 17 mentally normal subjects was above the upper limit of normal for younger subjects, and there was a broad relationship between increasing ventricular dilatation and increasing intellectual impairment. No such clear relationship was demonstrable for measures of cortical atrophy.  (+info)

Computerised axial tomography in patients with severe migraine: a preliminary report. (11/28924)

Patients suffering from severe migraine, usually for many years, have been examined by the EMI scanner between attacks. Judged by criteria validated originally by comparison with pneumoencephalography, about half of the patients showed evidence of cerebral atrophy. Perhaps of more significance than generalised atrophy was the frequency of areas of focal atrophy and of evidence of infarction.  (+info)

Double gallbladder originating from left hepatic duct: a case report and review of literature. (12/28924)

BACKGROUND: Double gallbladder is a rare anomaly of the biliary tract. Double gallbladder arising from the left hepatic duct was previously reported only once in the literature. CASE REPORT: A case of symptomatic cholelithiasis in a double gallbladder, diagnosed on preoperative ultrasound, computed tomography (CT) and endoscopic retrograde cholangiopancreatogram (ERCP) is reported. At laparoscopic cholangiography via the accessory gallbladder no accessory cystic duct was visualized. After conversion to open cholecystectomy, the duplicated gallbladder was found to arise directly from the left hepatic duct; it was resected and the duct repaired. CONCLUSIONS: We emphasize that a careful intraoperative cholangiographic evaluation of the accessory gallbladder is mandatory in order to prevent inadvertent injury to bile ducts, since a large variety of ductal abnormality may exist.  (+info)

A new filtering algorithm for medical magnetic resonance and computer tomography images. (13/28924)

Inner views of tubular structures based on computer tomography (CT) and magnetic resonance (MR) data sets may be created by virtual endoscopy. After a preliminary segmentation procedure for selecting the organ to be represented, the virtual endoscopy is a new postprocessing technique using surface or volume rendering of the data sets. In the case of surface rendering, the segmentation is based on a grey level thresholding technique. To avoid artifacts owing to the noise created in the imaging process, and to restore spurious resolution degradations, a robust Wiener filter was applied. This filter working in Fourier space approximates the noise spectrum by a simple function that is proportional to the square root of the signal amplitude. Thus, only points with tiny amplitudes consisting mostly of noise are suppressed. Further artifacts are avoided by the correct selection of the threshold range. Afterwards, the lumen and the inner walls of the tubular structures are well represented and allow one to distinguish between harmless fluctuations and medically significant structures.  (+info)

Computed radiography dual energy subtraction: performance evaluation when detecting low-contrast lung nodules in an anthropomorphic phantom. (14/28924)

A dedicated chest computed radiography (CR) system has an option of energy subtraction (ES) acquisition. Two imaging plates, rather than one, are separated by a copper filter to give a high-energy and low-energy image. This study compares the diagnostic accuracy of conventional computed radiography to that of ES obtained with two radiographic techniques. One soft tissue only image was obtained at the conventional CR technique (s = 254) and the second was obtained at twice the radiation exposure (s = 131) to reduce noise. An anthropomorphic phantom with superimposed low-contrast lung nodules was imaged 53 times for each radiographic technique. Fifteen images had no nodules; 38 images had a total of 90 nodules placed on the phantom. Three chest radiologists read the three sets of images in a receiver operating characteristic (ROC) study. Significant differences in Az were only found between (1) the higher exposure energy subtracted images and the conventional dose energy subtracted images (P = .095, 90% confidence), and (2) the conventional CR and the energy subtracted image obtained at the same technique (P = .024, 98% confidence). As a result of this study, energy subtracted images cannot be substituted for conventional CR images when detecting low-contrast nodules, even when twice the exposure is used to obtain them.  (+info)

3D angiography. Clinical interest. First applications in interventional neuroradiology. (15/28924)

3D angiography is a true technical revolution that allows improvement in the quality and safety of diagnostic and endovascular treatment procedures. 3D angiography images are obtained by reconstruction of a rotational angiography acquisition done on a C-arm (GE Medical Systems) spinning at 40 degrees per second. The carotid or vertebral selective injection of a total of 15 ml of non-ionic contrast media at 3 ml/sec over 5 seconds allows the selection of the "arterial phase". Four hundred sixty 3D angiographic studies were performed from December 1996 to September 1998 on 260 patients and have been analyzed in MIP (Maximum Intensity Projection) and SSD (Shaded Surface Display) views. The exploration of intracranial aneurysms is simplified and only requires, for each vascular axis, a biplane PA and Lateral run followed by a single rotational angiography run. The 3D angiography image is available on the workstation's screen (Advantage Workstation 3.1, GE Medical Systems) in less than 10 minutes after the acquisition of the rotational run. It therefore allows one to analyze, during the intervention, the aneurysm's angioarchitecture, in particular the neck, and select the best therapeutic technique. When endovascular treatment is the best indication, 3D angiography allows one to define the optimal angle of view and accurately select the microcoils dimensions. 3D angiography replaces the multiple oblique views that used to be required to analyze the complex aneurysms and therefore allows a reduction of the total contrast medium quantity, the patient X-ray dose and the length of the intervention time which is a safety factor. Also, in particular for complex cases, it brings additional elements complementing the results of standard 2D DSA and rotational angiograms. In the cervical vascular pathology, 3D angiography allows for a better assessment of the stenosis level and of dissection lesions. Our current research activities focus on the matching without stereotactic frame between 3D X-ray angiography and volumetric MR acquisition, which should allow us to improve the treatment of intracerebral arterio-venous malformations (AVMs).  (+info)

Medullary thyroid carcinoma with multiple hepatic metastases: treatment with transcatheter arterial embolization and percutaneous ethanol injection. (16/28924)

A 54-year-old man with medullary thyroid carcinoma in the thyroid gland was unable to undergo total thyroidectomy because the tumor had invaded the mediastinum. Radiation therapy and chemotherapy were given. Seven years later, intractable diarrhea and abdominal pain appeared, and computed tomography demonstrated hypervascular tumors in the thyroid gland and in the liver. The tumors were successfully treated with percutaneous ethanol injection to a lesion in the thyroid gland and transcatheter arterial embolization followed by percutaneous ethanol injection to tumors in the liver. Transcatheter arterial embolization and percutaneous ethanol injection may be valuable in treating medullary thyroid carcinoma.  (+info)