Analysis of gabapentin in serum and plasma by solid-phase extraction and gas chromatography-mass spectrometry for therapeutic drug monitoring. (1/50409)

A simple method for the determination of gabapentin (Neurontin) is described. The method uses solid-phase extraction by disk column and derivatization followed by gas chromatographic-mass spectrometric analysis. The single-step derivatization with MTBSTFA produces a t-BDMS derivative of both the carboxylic and amine moieties of the molecule. Each step of the procedure was optimized to assure reliable performance of the method. The assay limit of detection was 0.1 microg/mL with a linear range from 1.0 to 35 microg/mL. Within-run (n = 3) and between-run (n = 40) coefficients of variation were less than 8.2 and 15.9%, respectively. The method has proven reliable in routine production for more than a year, producing clean chromatography with unique ion fragments, consistent ion mass ratios, and no interferences. Statistical analysis of the gabapentin concentrations measured in 1020 random specimens over a 2-month period showed a mean concentration of 6.07 microg/mL with a standard deviation of 5.28.  (+info)

Solid-phase microextraction for cannabinoids analysis in hair and its possible application to other drugs. (2/50409)

This paper describes the application of solid-phase microextraction (SPME) to cannabis testing in hair. Fifty milligrams of hair was washed with petroleum ether, hydrolyzed with NaOH, neutralized, deuterated internal standard was added and directly submitted to SPME. The SPME was analyzed by GC-MS. The limit of detection was 0.1 ng/mg for cannabinol (CBN) and delta9-tetrahydrocannabinol (THC) and 0.2 ng/mg for cannabidiol (CBD). THC was detected in a range spanning from 0.1 to 0.7 ng/mg. CBD concentrations ranged from 0.7 to 14.1 ng/mg, and CBN concentrations ranged from 0.4 to 0.7 ng/mg. The effectiveness of different decontamination procedures was also studied on passively contaminated hair. The proposed method is also suitable for the analysis of methadone in hair; cocaine and cocaethylene can be detected in hair with SPME extraction after enzymatic hydrolysis.  (+info)

Highly sensitive quantitation of methamphetamine by time-resolved fluoroimmunoassay using a new europium chelate as a label. (3/50409)

A simple and highly sensitive time-resolved fluoroimmunoassay of methamphetamine (MA) using a new fluorescent europium chelate (BHHCT-Eu3+) as a label is described. Two variations of competitive immunoassay were attempted. In the first (one-step) assay, microtiter plates coated with anti-MA were used, and the new label was bound to a conjugate of bovine serum albumin and N-(4-aminobutyl)-MA (MA-BSA). In the second (two-step) assay, instead of the labeled MA-BSA, biotinylated MA-BSA and BHHCT-Eu3+-labeled streptavidin-BSA were used. The lowest measurable concentrations of MA for the one-step and the two-step methods were 1 ng/mL (25 pg/assay) and 1 pg/mL (25 fg/assay), respectively. These were 10 to 1000 times superior to the detection limits of MA in any other immunoassay. Intra-assay coefficient of variation was approximately 2-8% at eight different concentrations (n = 4). Analysis of 34 urine samples with the new method and conventional gas chromatography showed a good correlation (r = 0.954). The high detectability of the present assay also enabled segmental hair analysis with a few centimeters of a hair.  (+info)

Semiautomated preparation of 3,5,6-trichloro-2-pyridinol in human urine using a Zymate XP laboratory robot with quantitative determination by gas chromatography-negative-ion chemical ionization mass spectrometry. (4/50409)

A rapid and sensitive semiautomated method was developed for quantitation of the chlorpyrifos metabolite 3,5,6-trichloro-2-pyridinol (TCP) in human urine. A Zymark Zymate XP laboratory robotics system was used to mix urine samples, transfer aliquots, add the stable-isotope-labeled TCP internal standard (13C2- or 13C2,15N-), and liberate conjugates of TCP from urine via acid hydrolysis. Samples were manually extracted into toluene, derivatized, and analyzed by gas chromatography-negative-ion chemical ionization mass spectrometry. Determination of the metabolic TCP was performed by selected ion monitoring of the dichloropyridinol fragment ions: m/z 161 for TCP and m/z 165 for 13C2-TCP or m/z 168 for 13C2,15N-TCP. Interday precision and accuracy were demonstrated over 3 years of analyses using the 13C2-TCP internal standard, with an average recovery from fortified urine samples of 93+/-12% (N = 54, concentration range 1-140 ng/mL). The method was found to be linear over the range of 0.5 to 200 ng/mL, and the limit of detection for TCP in urine was estimated to be 0.2 ng/mL with a limit of quantitation of 1 ng/mL. The effect of solids distribution on the concentration of TCP in the thawed urine samples was examined, and the results indicated that homogeneous distribution is critical for quantitation. The precision and accuracy of the automated method with respect to the transfer of homgeneous urine aliquots and delivery of internal standard yielded equivalent or improved results over the manual techniques. Overall, this method is more simple than existing methodologies, and it yields results with improved precision, accuracy, and sensitivity over previously developed methods.  (+info)

Identification and quantification of cocaine N-oxide: a thermally labile metabolite of cocaine. (5/50409)

In this article, we report the identification and quantitation of cocaine N-oxide (CNO), a thermally labile oxidative metabolite, from both animal and human samples. The concentration of CNO is similar to the concentrations of cocaine in the samples analyzed. The technique used for the determination of CNO in this study is liquid chromatography-electrospray ionization mass spectrometry, which is necessary because CNO is converted to cocaine upon heating. This includes simple heating of aqueous solutions to temperatures in excess of 100 degrees C and analysis by gas chromatography-mass spectrometry (GC-MS), in which CNO is converted to cocaine in the injection port. The thermal conversion of CNO to cocaine is estimated to cause an over-reporting of cocaine levels by 10-20% when using GC-MS.  (+info)

Hybrid capture II, a new sensitive test for human papillomavirus detection. Comparison with hybrid capture I and PCR results in cervical lesions. (6/50409)

AIM: To test a new assay for the detection of human papillomavirus (HPV) DNA, hybrid capture II (HC II), compared with the previous commercialized hybrid capture I (HC I) and polymerase chain reaction (PCR) results on cervical scrapes from fresh cone excision biopsy samples. METHODS: The three methods were used on cervical scrapes from 42 fresh cone excision biopsy samples. There were nine metaplastic and inflammatory lesions, five low grade lesions, and 28 high grade lesions. PCR was performed using the general primers GP5+/GP6+. The viral load of high risk HPV DNA was estimated by the ratio of relative light units to positive control values in the samples. RESULTS: The sensitivity of HC I for the detection of high grade lesions was 71.4%, while it was 92.8% for HC II and 96.4% for the PCR. Considering only the absence of detectable cervical in situ neoplasia, the specificity was 88.9% for HC I, 66.7% for HC II, and 66.7% for PCR. With HC II, for a ratio of cervical sample to normal control of > 200, the sensitivity for the detection of high grade lesion was only 34.6% with a specificity of 66.7%. CONCLUSIONS: HPV detection with the HC II assay is more sensitive than the previous HC I and represents a more convenient and easier test than PCR for routine use. Nevertheless the viral load estimated with this test cannot be a reliable predictive indicator of high grade lesions.  (+info)

Comparative efficacy of positron emission tomography with FDG and computed tomographic scanning in preoperative staging of non-small cell lung cancer. (7/50409)

OBJECTIVE: To determine the sensitivity, specificity, and accuracy of positron emission tomography with 2-fluorine-18-fluorodeoxyglucose (PET-FDG) in the preoperative staging (N and M staging) of patients with lung cancer. The authors wanted to compare the efficacy of PET scanning with currently used computed tomography (CT) scanning. MATERIALS AND METHODS: Results of whole-body PET-FDG imaging and CT scans were compared with histologic findings for the presence or absence of lymph node disease or metastatic sites. Sampling of mediastinal lymph nodes was performed using mediastinoscopy or thoracotomy. RESULTS: PET-FDG imaging was significantly more sensitive, specific, and accurate for detecting N disease than CT. PET changed N staging in 35% and M staging in 11% of patients. CT scans helped in accurate anatomic localization of 6/57 PET lymph node abnormalities. CONCLUSION: PET-FDG is a reliable method for preoperative staging of patients with lung cancer and would help to optimize management of these patients. Accurate lymph node staging of lung cancer may be ideally performed by simultaneous review of PET and CT scans.  (+info)

Screening for congenital heart malformation in child health centres. (8/50409)

BACKGROUND: Although screening for congenital heart malformations is part of the child health care programme in several countries, there are very few published evaluations of these activities. This report is concerned with the evaluation of this screening at the Dutch Child Health Centres (CHC). METHODS: All consecutive patients, aged between 32 days and 4 years, presented at the Sophia Children's Hospital Rotterdam throughout a period of 2 years, with a congenital heart malformation were included in this study. Paediatric cardiologists established whether or not these patients were diagnosed after haemodynamic complications had already developed (diagnosed 'too late'). Parents and CHC-physicians were interviewed in order to establish the screening and detection history. Test properties were established for all patients with a congenital heart malformation (n = 290), intended effects of screening were established in patients with clinically significant malformations (n = 82). RESULTS: The sensitivity of the actual screening programme was 0.57 (95% CI : 0.51-0.62), the specificity 0.985 (95% CI : 0.981-0.990) and the predictive value of a positive test result 0.13 (95% CI: 0.10-0.19). Sensitivity in a subpopulation of patients adequately screened was 0.89 (95% CI: 0.74-0.96). Adequately screened patients were less likely to be diagnosed 'too late' than inadequately screened patients (odds ratio [OR] = 0.20, 95% CI: 0.04-1.05). The actual risk of being diagnosed 'too late' in the study-population (48%) was only slightly less than the estimated risk for patients not exposed to CHC-screening (58%, 95% CI: 43%-72%). Adequately screened patients however were at considerably less risk (17%, 95% CI: 4%-48%). CONCLUSION: Screening for congenital heart malformations in CHC contributes to the timely detection of these disorders. The actual yield, however, is far from optimal, and the screening programme should be improved.  (+info)