An analysis of an implantable dosimeter system for external beam therapy. (57/426)

BACKGROUND AND PURPOSE: To review the data from an implantable radiation dosimetry system used in a clinical setting and to examine correlations between dosimeter readings and potential causative error sources. MATERIALS AND METHODS: MOSFET (metal oxide semiconductor field effect transistor) based encapsulated dosimeters were evaluated in a phantom (in vitro) and in a study with 18 patients. The dosimeters were placed in the gross tumor volume or in collateral normal tissue. Predicted dose values were established by imaging the dosimeters in the planning CTs. RESULTS: The in vitro study confirmed that bounding cumulative errors due to setup, planning, and machine output within a +/-5% level is achievable. In patients, it was found that deviations from the targeted dose often exceeded the 5% level. CONCLUSIONS: The use of an implantable dosimeter system could provide an effective empiric check on the dose delivered at depth. Such a tool may have value for institutional quality assurance, as well as for therapy delivered to individual patients.  (+info)

A comparison of tungsten-quartz-halogen, plasma arc and light-emitting diode light sources for the polymerization of an orthodontic adhesive. (58/426)

This study investigated whether there were differences between the debond stress and adhesive remnant index (ARI) of an adhesive cured with three different orthodontic light sources. Sixty sound premolar teeth were divided into three groups of 20. A standard pre-adjusted edgewise premolar bracket (Victory Series) was bonded to each tooth using a light-cured orthodontic adhesive, Transbond X. Group 1 (control) specimens were cured with an Ortholux XT (tungsten-quartz-halogen bulb) light for 20 seconds, group 2 with an Ortho lite (plasma arc) for 6 seconds and group 3 with an Ortholux LED light-emitting diode for 10 seconds. The specimens were debonded 24 hours later using a universal mechanical testing machine, operating at a crosshead speed of 0.5 mm minute(-1). The Weibull modulus and a Logrank test showed no statistically significant differences between the three groups for debond stress. The ARI was assessed at x10 magnification. The ARI scores for group 2 were significantly different (P < 0.01) from those of groups 1 and 3 (between which there was no significant difference). For group 2 there was a greater tendency for failure to occur at the adhesive/tooth interface than for the other two groups. There appears to be no reason why any of the three types of light source cannot be used in orthodontics. Polymerization, as effective as that produced by conventional bulb light sources, was obtained with the short exposure times recommended for the plasma arc or light-emitting diode sources.  (+info)

Cancer incidence and cancer mortality in a cohort of UK semiconductor workers, 1970-2002. (59/426)

OBJECTIVE: To examine cancer risks in a cohort of workers employed in the manufacture of semiconductors. METHODS: The mortality (1970-2002) and cancer morbidity (1971-2001) experienced by a cohort of 1807 male and female workforce employees from a semiconductor factory in the West Midlands (UK) have been investigated. Standardized mortality ratios (SMRs) and standardized registration ratios (SRRs) were used to assess mortality and morbidity, respectively. RESULTS: Overall mortality was close to expectation in males [SMR 99, 95% (confidence interval) CI 79-122] and significantly below expectation in females (SMR 74, 95% CI 65-85). Incidence of all sites of cancer was somewhat elevated in males (SRR 130, 95% CI 95-173) but close to expectation in females (SRR 94, 95% CI 82-109). There were significant deficits of deaths from cancer of the oesophagus in males and females combined and from cancer of the breast in females. Significantly elevated SRRs were found in males for cancer of the rectum [Observed (Obs) 6, SRR 284, 95% CI 104-619], in females for cancer of the pancreas (Obs 10, SRR 226, 95% CI 108-415) and malignant melanoma (Obs 11, SRR 221, 95% CI 110-396) and in males and females combined for cancer of the rectum (Obs 19, SRR 199, 95% CI 120-310) and malignant melanoma (Obs 12, SRR 217, 95% CI 112-379). Detailed work history data were unavailable for analysis. The finding of excess morbidity was not mirrored in the corresponding mortality findings. CONCLUSIONS: The study found elevated morbidity for a number of cancer sites that may be unconnected with occupation. Elimination of all possible occupational causes will, however, require more detailed analyses of cancer risks in relation to exposure histories.  (+info)

Bioconjugation of quantum dot luminescent probes for Western blot analysis. (60/426)

Western blot analysis is a widely used technique for protein immunodetection. Its current format, however is unsuitable for multiplex detection of proteins, primarily due to intrinsic limitations of standard organic dyes employed as probes. Quantum dot (QD) semiconductor nanoparticles exhibit significant advantages over organic dyes, including their broad absorption bands, narrow, tunable, and symmetric emission spectra, large Stokes shifts, and excellent photostability. Here we describe a novel method for the functionalization of streptavidin-coated QDs with an in vivo biotinylated peptide (head-to-tail dimerized Z domain derived from protein A) that permits the facile conjugation of antibodies to QDs. In this study, we demonstrate the simultaneous detection of two different types of protein in a Western blot. The bioconjugation of QDs described here makes it possible to achieve multiplex detection of proteins in Western blot analysis in a more straightforward manner.  (+info)

The use of lasers for periodontal debridement: marketing tool or proven therapy? (61/426)

The use of lasers in dentistry has recently received much attention, in both clinical practice and research; their unique properties produce favourable clinical results in some cases and encourage patient acceptance. Various types of lasers have been investigated as an adjunct to periodontal therapy; these include carbon dioxide (CO2), diode, neodymium:yttrium-aluminium-garnet (Nd:YAG) and erbium:yttrium-aluminium-garnet (Er:YAG) lasers.However, adverse results have been associated with each type, including thermal damage to root surfaces, increases in pulpal temperature and the production of toxic by-products. The Er:YAG laser has produced the most promising results, as it can ablate effectively with minimal adverse effects. More research is needed to determine the ideal settings and methods for using the laser safely and effectively in clinical practice.  (+info)

Occupational health provision and health surveillance in the semiconductor industry. (62/426)

AIMS: To identify the nature of occupational health provision in UK semiconductor-manufacturing plants. To identify the level of industry compliance with legal health surveillance requirements. METHOD: A national inspection programme was carried out by Health & Safety Executive inspectors using a developed protocol. RESULTS: A wide range of occupational health provision was identified from none to use of an accredited specialist. The majority of work was of a reactive nature even where there was specialist occupational health input. Seven companies were identified as not meeting legal compliance and one as having unacceptable compliance for health surveillance. CONCLUSIONS: The spectrum of occupational health provision was very wide. Where health surveillance was provided, it was poorly targeted with limited interpretation and feedback to management.  (+info)

Smell intensity monitoring using metal oxide semiconductor odor sensors during intravenous olfaction test. (63/426)

The intravenous olfaction test using prosultiamine (PST) solution is simple to perform and has been used clinically in Japan. We monitored intranasal intensity of smell continuously in real time under various conditions of administration using metal oxide semiconductor odor sensors and established an optimal PST injection procedure. In this study, we found that 1) although there was fluctuation in the pattern of intensity of increase in smell in the PST original solution test, the pattern of increase in intranasal smell intensity could be stabilized by prolonging the injection time to 40 s and 2) dilution of PST with physiological saline was effective in preventing angialgia during intravenous injection. It appears that PST administration is best performed by adding 10 ml of saline to 10 mg (2 ml) of PST and injecting the resulting 12-ml solution (6x dilution) and that the best respiratory cycle for testing is once in every 2 s.  (+info)

115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser. (64/426)

We demonstrate an ultrahigh-speed wavelength-swept semiconductor laser using a polygon-based wavelength scanning filter. With a polygon rotational speed of 900 revolutions per second, a continuous wavelength tuning rate of 9200 nm/ms and a tuning repetition rate of 115 kHz were achieved. The wavelength tuning range of the laser was 80 nm centered at 1325 nm, and the average polarized output power was 23 mW.  (+info)