Heart rate variability and ischaemia in patients with coronary heart disease and stable angina pectoris; influence of drug therapy and prognostic value. TIBBS Investigators Group. Total Ischemic Burden Bisoprolol Study. (65/49462)

AIMS: Determination of the influence of therapy with bisoprolol and nifedipine on the heart rate variability of patients from the Total Ischemic Burden Bisoprolol Study and examination of the prognostic value. METHODS AND RESULTS: Four hundred and twenty-two patients with stable angina were included. The heart rate variability was determined over a period of 24 h. Parameters determined: standard deviation of the mean of all corrected RR intervals, standard deviation of all 5 min mean cycle lengths, square root of the mean of the squared differences of successive corrected RR intervals. Nifedipine reduced the mean values of all heart rate variability parameters tested. Square root of the mean of the square differences of successive corrected RR intervals increased under bisoprolol. Standard deviation of the mean of all corrected RR intervals and standard deviation of all 5 min mean cycle lengths increased from low baseline values and declined from higher baseline values. The increase in heart rate variability under therapy was accompanied by a tendency towards a better prognosis. Patients with an increase in heart rate variability and simultaneous complete suppression of ischaemia under therapy displayed no serious events in the course of one year. CONCLUSIONS: The increase in the heart rate variability, which can be regarded as prognostically favourable, was predominantly observed under bisoprolol. The parameter constellation of an increase in heart rate variability and complete ischaemia suppression on the 48-h Holter ECG was associated with the greatest benefit.  (+info)

Comparison of indirect calorimetry, the Fick method, and prediction equations in estimating the energy requirements of critically ill patients. (66/49462)

BACKGROUND: Accurate measurement of resting energy expenditure (REE) is helpful in determining the energy needs of critically ill patients requiring nutritional support. Currently, the most accurate clinical tool used to measure REE is indirect calorimetry, which is expensive, requires trained personnel, and has significant error at higher inspired oxygen concentrations. OBJECTIVE: The purpose of this study was to compare REE measured by indirect calorimetry with REE calculated by using the Fick method and prediction equations by Harris-Benedict, Ireton-Jones, Fusco, and Frankenfield. DESIGN: REEs of 36 patients [12 men and 24 women, mean age 58+/-22 y and mean Acute Physiology and Chronic Health Evaluation II score 22+/-8] in a hospital intensive care unit and receiving mechanical ventilation and total parenteral nutrition (TPN) were measured for > or = 15 min by using indirect calorimetry and compared with REEs calculated from a mean of 2 sets of hemodynamic measurements taken during the metabolic testing period with an oximetric pulmonary artery catheter. RESULTS: Mean REE by indirect calorimetry was 8381+/-1940 kJ/d and correlated poorly with the other methods tested (r = 0.057-0.154). This correlation did not improve after adjusting for changes in respiratory quotient (r2 = 0.28). CONCLUSIONS: These data do not support previous findings showing a strong correlation between REE determined by the Fick method and other prediction equations and indirect calorimetry. In critically ill patients receiving TPN, indirect calorimetry, if available, remains the most appropriate clinical tool for accurate measurement of REE.  (+info)

Validation of a specific quality of life questionnaire for functional digestive disorders. (67/49462)

BACKGROUND: Dyspepsia and irritable bowel syndrome are suitable conditions for assessment of quality of life. Their similarities justify the elaboration of a single specific questionnaire for the two conditions. AIMS: To examine the process leading to the validation of the psychometric properties of the functional digestive disorders quality of life questionnaire (FDDQL). METHODS: Initially, the questionnaire was given to 154 patients, to assess its acceptability and reproducibility, analyse its content, and reduce the number of items. Its responsiveness was tested during two therapeutic trials which included 428 patients. The questionnaire has been translated into French, English, and German. The psychometric validation study was conducted in France, United Kingdom, and Germany by 187 practitioners. A total of 401 patients with dyspepsia or irritable bowel syndrome, defined by the Rome criteria, filled in the FDDQL and generic SF-36 questionnaires. RESULTS: The structure of the FDDQL scales was checked by factorial analysis. Its reliability was expressed by a Cronbach's alpha coefficient of 0.94. Assessment of its discriminant validity showed that the more severe the functional digestive disorders, the more impaired the quality of life (p<0.05). Concurrent validity was supported by the correlation found between the FDDQL and SF-36 questionnaire scales. The final version of the questionnaire contains 43 items belonging to eight domains. CONCLUSIONS: The properties of the FDDQL questionnaire, available in French, English, and German, make it appropriate for use in clinical trials designed to evaluate its responsiveness to treatment among patients with dyspepsia and irritable bowel syndrome.  (+info)

Mediation of humoral catecholamine secretion by the renin-angiotensin system in hypotensive rainbow trout (Oncorhynchus mykiss). (68/49462)

The individual contributions of, and potential interactions between, the renin-angiotensin system (RAS) and the humoral adrenergic stress response to blood pressure regulation were examined in rainbow trout. Intravenous injection of the smooth muscle relaxant, papaverine (10 mg/kg), elicited a transient decrease in dorsal aortic blood pressure (PDA) and systemic vascular resistance (RS), and significant increases in plasma angiotensin II (Ang II) and catecholamine concentrations. Blockade of alpha-adrenoceptors before papaverine treatment prevented PDA and RS recovery, had no effect on the increase in plasma catecholamines, and resulted in greater plasma Ang II concentrations. Administration of the angiotensin-converting enzyme inhibitor, lisinopril (10(-4) mol/kg), before papaverine treatment attenuated the increases in the plasma concentrations of Ang II, adrenaline, and noradrenaline by 90, 79, and 40%, respectively and also prevented PDA and RS recovery. By itself, lisinopril treatment caused a gradual and sustained decrease in PDA and RS, and reductions in basal plasma Ang II and adrenaline concentrations. Bolus injection of a catecholamine cocktail (4 nmol/kg noradrenaline plus 40 nmol/kg adrenaline) in the lisinopril+papaverine-treated trout, to supplement their circulating catecholamine concentrations and mimic those observed in fish treated only with papaverine, resulted in a temporary recovery in PDA and RS. These results indicate that the RAS and the acute humoral adrenergic response are both recruited during an acute hypotensive stress, and have important roles in the compensatory response to hypotension in rainbow trout. However, whereas the contribution of the RAS to PDA recovery is largely indirect and relies on an Ang II-mediated secretion of catecholamines, the contribution from the adrenergic system is direct and relies at least in part on plasma catecholamines.  (+info)

A deviation bar chart for detecting dengue outbreaks in Puerto Rico. (69/49462)

OBJECTIVES: A Centers for Disease Control and Prevention deviation bar chart (Statistical Software for Public Health Surveillance) and laboratory-based surveillance data were evaluated for their utility in detecting dengue outbreaks in Puerto Rico. METHODS: A significant increase in dengue incidence was defined as an excess of suspected cases of more than 2 SDs beyond the mean for all 4-week periods from April through June (the period of lowest seasonal incidence), 1989 through 1993. An outbreak was defined as a cumulative annual rate of reported dengue greater than 3 per 1000 population. RESULTS: Retrospective application of the system to 1994 data showed agreement with previous analyses. In 1995 and 1996, 36.4% and 27.3%, respectively, of municipalities with a significant increase in reports for 2 or more consecutive weeks before the first week of September had an outbreak, compared with 9.0% (in 1995, P = .042) and 6.0% (in 1996, P = .054) of towns without a significant increase. The system showed sensitivity near 40%, specificity near 89%, and accuracy in classifying municipalities near 84%. CONCLUSIONS: This method provides a statistically based, visually striking, specific, and timely signal for dengue control efforts.  (+info)

LocaLisa: new technique for real-time 3-dimensional localization of regular intracardiac electrodes. (70/49462)

BACKGROUND: Estimation of the 3-dimensional (3D) position of ablation electrodes from fluoroscopic images is inadequate if a systematic lesion pattern is required in the treatment of complex arrhythmogenic substrates. METHODS AND RESULTS: We developed a new technique for online 3D localization of intracardiac electrodes. Regular catheter electrodes are used as sensors for a high-frequency transthoracic electrical field, which is applied via standard skin electrodes. We investigated localization accuracy within the right atrium, right ventricle, and left ventricle by comparing measured and true interelectrode distances of a decapolar catheter. Long-term stability was analyzed by localization of the most proximal His bundle before and after slow pathway ablation. Electrogram recordings were unaffected by the applied electrical field. Localization data from 3 catheter positions, widely distributed within the right atrium, right ventricle, or left ventricle, were analyzed in 10 patients per group. The relationship between measured and true electrode positions was highly linear, with an average correlation coefficient of 0.996, 0.997, and 0.999 for the right atrium, right ventricle, and left ventricle, respectively. Localization accuracy was better than 2 mm, with an additional scaling error of 8% to 14%. After 2 hours, localization of the proximal His bundle was reproducible within 1.4+/-1.1 mm. CONCLUSIONS: This new technique enables accurate and reproducible real-time localization of electrode positions in cardiac mapping and ablation procedures. Its application does not distort the quality of electrograms and can be applied to any electrode catheter.  (+info)

Is blood glucose predictable from previous values? A solicitation for data. (71/49462)

An important question about blood glucose control in diabetes is, Can present and future blood glucose values be predicted from recent blood glucose history? If this is possible, new continuous blood glucose monitoring technologies under development may lead to qualitatively better therapeutic capabilities. Not only could continuous monitoring technologies alert a user when a hypoglycemic episode or other blood glucose excursion is underway, but measurements may also provide sufficient information to predict near-future blood glucose values. A predictive capability based only on recent blood glucose history would be advantageous because there would be no need to involve models of glucose and insulin distribution, with their inherent requirement for detailed accounting of vascular glucose loads and insulin availability. Published data analyzed here indicate that blood glucose dynamics are not random, and that blood glucose values can be predicted, at least for the near future, from frequently sampled previous values. Data useful in further exploring this concept are limited, however, and an appeal is made for collection of more.  (+info)

Utility of ultrasound of the upper urinary tract in elderly men with indicators of obstructive symptoms or abnormal flow: how often can silent hydronephrosis be detected in general practice? (72/49462)

BACKGROUND AND OBJECTIVE: While the prevalence of hydronephrosis is very low in obduction studies, a prevalence of 3-13% is reported for patients with an obstruction who are listed for prostatectomy. In order to evaluate the usefulness of transabdominal ultrasound in primary care, we determined the occurrence of hydronephrosis in males with symptoms of urinary obstruction in a general practice setting. METHOD: A micturition questionnaire (a modified Boyarsky) was sent to all men of 55 years or more who were registered in 10 general practices in Maastricht, and was followed by an examination at their general practice. Men with obstructive symptoms and/or with a free-flow abnormality were examined in the hospital with transabdominal ultrasound in order to detect dilatation of the upper urinary tract. This ultrasound was repeated approximately 15 months later. RESULTS: At the first measurement, none of the examined men (n = 178) had hydronephrosis, and this was still the case for 94 men 15 months later. CONCLUSION: Renal ultrasound is not necessary in general practice for men with uncomplicated obstructive complaints.  (+info)