Chondrocalcinosis after parathyroidectomy. (49/18686)

In this retrospective study of 57 patients with primary hyperparathyroidism who underwent parathyroidectomy, the overall incidence of chondrocalcinosis was 40%. Neither joint symptoms nor chondrocalcinosis regressed after the operation. In several patients the condition appeared to deteriorate both clinically and radiologically after the operation, while in a few both the chondrocalcinosis and the associated symptoms first appeared some time after the operation.  (+info)

Mechanisms of death in the CABG Patch trial: a randomized trial of implantable cardiac defibrillator prophylaxis in patients at high risk of death after coronary artery bypass graft surgery. (50/18686)

BACKGROUND: The CABG Patch trial compared prophylactic implantable cardiac-defibrillator (ICD) implantation with no antiarrhythmic therapy in coronary bypass surgery patients who had a left ventricular ejection fraction <0.36 and an abnormal signal-averaged ECG. There were 102 deaths among the 446 ICD group patients and 96 deaths among the 454 control group patients, a hazard ratio of 1.07 (P=0.63). The mechanisms of death were classified, and hypotheses were tested about the effects of ICD therapy on arrhythmic and nonarrhythmic cardiac deaths in the CABG Patch Trial and the Multicenter Automatic Defibrillator Implantation Trial (MADIT). METHODS AND RESULTS: The 198 deaths in the trial were reviewed by an independent Events Committee and classified by the method of Hinkle and Thaler. Only 54 deaths (27%) occurred out of hospital; 145 deaths (73%) were witnessed. Seventy-nine (82%) of the 96 deaths in the control group and 76 (75%) of the 102 deaths in the ICD group were due to cardiac causes. Cumulative arrhythmic mortality at 42 months was 6.9% in the control group and 4.0% in the ICD group (P=0. 057). Cumulative nonarrhythmic cardiac mortality at 42 months was 12. 4% in the control group and 13.0% in the ICD group (P=0.275). Death due to pump failure was significantly associated with death >1 hour from the onset of symptoms, dyspnea within 7 days of death, and overt heart failure within 7 days of death. CONCLUSIONS: In the CABG Patch Trial, ICD therapy reduced arrhythmic death 45% without significant effect on nonarrhythmic deaths. Because 71% of the deaths were nonarrhythmic, total mortality was not significantly reduced.  (+info)

Pregnancy in patients after valve replacement. (51/18686)

This report is based on information obtained from a questionnaire sent to major cardiac centres in the United Kingdom. This produced details of 39 pregnancies in 34 patients after valve replacement. The 39 pregnancies gave rise to 30 healthy babies. The small size of the series probably reflects both the increasing rarity of young women with rheumatic heart disease in this country and the cautious attitude of their cardiologists. This makes it likely that these women represented the best end of the spectrum of cardiac function after valve replacement. Twenty-four pregnancies in 20 women who were not given anticoagulants producted 23 healthy babies and 1 spontaneous abortion. This group comprised 6 patients with free aortic homografts, 1 patient with a fascia lata mitral valve, 1 with a Beall tricuspid prosthesis, 1 with a combined mitral homograft and Starr Edwards aortic prosthesis, and 1 with mitral and aortic frame-mounted fascia lata valves. There were no maternal deaths or thromboembolic complications in this group which included 5 patients who were in atrial fibrillation. Fifteen pregnancies in 14 women who received anticoagulants gave rise to 7 healthy babies. The fetal losses were one stillbirth, one intrauterine death at 34 weeks, and 3 spontaneous abortions; one surviving child has hydrocephalus as a result of blood clot and there were 2 maternal deaths. This group included 13 patients with Starr Edwards valves, 11 mitral and 2 aortic. A patient with a Hammersmith mitral valve was the only one to have been treated with heparin and her valve thrombosed. One patient with a mounted mitral homograft had a cerebral embolus. Nine of these patients were in atrial fibrillation. In 3 additional patients the valve replacement was carried out during pregnancy. Two of the patients survived operation. In one of these who was treated with warfarin the pregnancy well, but there is an increased fetal wastage in patients pregnancy gave rise to a congenitally malformed baby who died in the neonatal period. The baby born to the mother who did not receive anticoagulants has a hare-lip and talipes. Women with artificial valves can tolerate the haemodynamic load of pregnancy well, but there is an increased fetal wastage in patients taking oral anticoagulants. This is probably largely attributable to fetal haemorrhage but there is also a risk of malformation caused by a teratogenic effect of warfarin. Experience gained in non-pregnant patients suggests that withholding anticoagulatns in pregnant patients with prosthetic valves would usually be undersirable but warfarin should be avoided. The advantages of biological valves were apparent in this series.  (+info)

Intraoperative left ventricular perforation with false aneurysm formation. (52/18686)

Two cases of perforation of the left ventricle during mitral valve replacement are described. In the first case there was perforation at the site of papillary muscle excision and this was recognized and successfully treated. However, a true ventricular aneurysm developed at the repair site. One month after operation rupture of the left ventricle occurred at a second and separate site on the posterior aspect of the atrioventricular ring. This resulted in a false aneurysm which produced a pansystolic murmur mimicking mitral regurgitation. Both the true and the false aneurysm were successfully repaired. In the second case perforation occurred on the posterior aspect of the atrioventricular ring and was successfully repaired. However, a false ventricular aneurysm developed and ruptured into the left atrium producing severe, but silent, mitral regurgitation. This was recognized and successfully repaired. The implications of these cases are discussed.  (+info)

Left ventricle to pulmonary artery conduit in treatment of transposition of great arteries, restrictive ventricular septal defect, and acquired pulmonary atresia. (53/18686)

Progressive cyanosis after banding of the pulmonary artery in infancy occurred in a child with transposition of the great arteries and a ventricular septal defect, and a Blalock-Taussig shunt operation had to be performed. At the time of correction a segment of pulmonary artery between the left ventricle and the band was found to be completely occluded so that continuity between the left ventricle and the pulmonary artery could not be restored. A Rastelli type of operation was not feasible as the ventricular septal defect was sited low in the muscular septum. Therefore, in addition to Mustard's operation, a Dacron conduit was inserted from the left ventricle to the main pulmonary artery to relieve the obstruction. Postoperative cardiac catheterization with angiocardiography indicated a satisfactory haemodynamic result. The patient remains well 11 months after the operation. This operation, a left ventricle to pulmonary artery conduit, may be used as an alternative procedure in patients with transposition of the great arteries, intact interventricular septum, and obstruction to the left ventricular outflow, if the obstruction cannot be adequately relieved.  (+info)

Reversion to sinus rhythm 11 years after surgically induced heart block. (54/18686)

A patient is presented in whom the heart reverted spontaneously to sinus rhythm 11 years after surgical closure of a ventricular septal defect complicated by complete heart block. It seems unlikely that regeneration of fibres in the bundle of His, if these had indeed been destroyed, could account for the restoration of sinus rhythm after so long an interval.  (+info)

Vitrectomy in 125 eyes with diabetic vitreous haemorrhage. (55/18686)

A total of 125 consecutive eyes, all registered blind with diabetic vitreous haemorrhage, underwent pars plana vitrectomy with the vitrophage. Sixty-six per cent experienced some improvement in their visual acuity; 24 per cent were unchanged and 10 per cent were worse postoperatively. The major surgical complication was controllable haemorrhage (23 per cent). No retinal dialysis occurred. Significant postoperative complications were transient (71 per cent) and persistent (11 per cent) corneal oedema, early (8 per cent) and late (13 per cent) vitreous haemorrhage, transient (30 per cent) and persistent (6 per cent) rise in intraocular pressure, and rubeosis iridis (5 per cent).  (+info)

Perifoveal vascular leakage and macular oedema after intracapsular cataract extraction. (56/18686)

Perifoveal capillary leakage of fluorescein was demonstrated in 60 per cent of 50 eyes when angiography was performed two weeks after cataract extraction. Repeat angiography six weeks postoperatively in 17 eyes demonstrated persistence of already established leakage in 11 of 12 eyes and no new leakage in five eyes previously negative. Cystoid macular oedema with visual acuity of less than 20/40 six weeks postoperatively occurred in five eyes (10 per cent). Eyes of patients with vascular disease and those patients of 60 years or older were found to have altered vascular permeability significantly more frequently. Inflammation was no more severe or prevalent in those patients who demonstrated leakage and no inflammation was clinically apparent in 10 of 11 eyes demonstrating dye leakage six weeks postoperatively. We conclude that the constitutional factors of age and vascular disease are of prime importance in causing altered vascular permeability in the early postoperative period after cataract extraction; factors causing sustained leakage with reduction of visual acuity were not demonstrated.  (+info)