The influence of low-level laser therapy on biomodulation of collagen and elastic fibers. (9/232)

The study of low-level laser therapy upon extracellular matrix elements is important to understand the wound healing process under this agent. However, little is known about the interference of laser light in relation to collagen and elastic fibers. Cutaneous wounds were performed on the back of 72 Wistar rats and a Ga-Al-As low-level laser was punctually applied with different energy densities. The animals were killed after 24, 48, 72 hours and 5, 7 and 14 days. Tissues were stained with hematoxilin-eosin, sirius red fast green and orcein and then analyzed. It was observed that the treated group exhibited larger reduction of edema and inflammatory infiltrate. The treated animals presented a larger expression of collagen and elastic fibers, although without statistical significance (p > 0.05). Treatment with a dosage of 4 J/cm(2) exhibited more expressive results than that with 8 J/cm(2). In this study, the authors concluded that low-level laser therapy contributed to a larger expression of collagen and elastic fibers during the early phases of the wound healing process.  (+info)

Transcranial infrared laser therapy improves clinical rating scores after embolic strokes in rabbits. (10/232)

BACKGROUND AND PURPOSE: Because photon energy delivered using a low-energy infrared laser may be useful to treat stroke, we determined whether transcranial laser therapy would improve behavioral deficits in a rabbit small clot embolic stroke model (RSCEM). METHODS: In this study, the behavioral and physiological effects of laser treatment were measured. The RSCEM was used to assess whether low-energy laser treatment (7.5 or 25 mW/cm2) altered clinical rating scores (behavior) when given to rabbits beginning 1 to 24 hours postembolization. Behavioral analysis was conducted from 24 hours to 21 days after embolization, allowing for the determination of the effective stroke dose (P50) or clot amount (mg) that produces neurological deficits in 50% of the rabbits. Using the RSCEM, a treatment is considered beneficial if it significantly increases the P50 compared with the control group. RESULTS: In the present study, the P50 value for controls were 0.97+/-0.19 mg to 1.10+/-0.17 mg; this was increased by 100% to 195% (P50=2.02+/-0.46 to 2.98+/-0.65 mg) if laser treatment was initiated up to 6 hours, but not 24 hours, postembolization (P50=1.23+/-0.15 mg). Laser treatment also produced a durable effect that was measurable 21 days after embolization. Laser treatment (25 mW/cm2) did not affect the physiological variables that were measured. CONCLUSIONS: This study shows that laser treatment improved behavioral performance if initiated within 6 hours of an embolic stroke and the effect of laser treatment is durable. Therefore, transcranial laser treatment may be useful to treat human stroke patients and should be further developed.  (+info)

Low power laser treatment in patients with knee osteoarthritis. (11/232)

The aim of this study was to investigate the analgesic efficacy of low power laser therapy in patients with knee osteoarthritis (OA). The study design was randomised, placebo-controlled and single blinded. Sixty patients with knee OA according to the American College of Rheumatology criteria were included and randomly assigned to three treatment groups: active laser with dosage of 3 J/per painful point, active laser with a dosage of 1.5/J per painful point and placebo laser treatment groups. A Gal-Al-As diode laser device was used as a source of low power laser with a power output of 50 mW and a wavelength of 830 nm. The patients were treated 5 times weekly with 10 treatments in all. The clinical assessments included Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain, stiffness and physical function subscales. In addition, the intensity of pain at rest and on activation was evaluated on a visual analogue scale. Compared to baseline, at week 3 and at month 6, no significant improvement was observed within the groups. Similarly, no significant differences were found among the treatment groups at any time. With the chosen laser type and dose regimen the results that we obtained in this study, suggest that low-level laser therapy has no effect on pain in patients with knee OA.  (+info)

Comparison of characteristics of acquired bilateral nevus of Ota-like macules and nevus of Ota according to therapeutic outcome. (12/232)

Both acquired bilateral nevus of Ota-like macules (ABNOM) and nevus of Ota are characterized by the presence of dermal melanocytes. There are no differences in the method of treatment, however, postinflammatory hyperpigmentation (PIH) develops more often in ABNOM than in nevus of Ota following treatment. We investigated the differences in the development of PIH after treatment between ABNOM and nevus of Ota, and the histopathologic differences in the PIH. A total of 82 patients with ABNOM (n=47) and nevus of Ota (n=35) were treated with Q-switched alexandrite laser and followed up 2 weeks and 3 months later. Biopsies were performed on lesional skin before treatment. The distribution and the amount of melanin pigments were visualized with Fontana-Masson stain, and the distribution and the depth of melanocytes were measured by GP-100 (NK1-beteb) stain. Clinically, there was more erythema and PIH in ABNOM than in nevus of Ota. Histopathologically, intradermal melanocytes were clustered in groups and dispersed perivascularly in ABNOM, while melanocytes were scattered evenly throughout the dermis in nevus of Ota. Both groups show that when there is a statistically significant number of melanocytes in the perivascular area, erythema and PIH occur after laser therapy. In conclusion, indirect vessel injury in addition to perivascular clustering melanocytes might be considered the cause of increased PIH after treatment in ABNOM.  (+info)

Effect of Ga-as laser on the regeneration of injured sciatic nerves in the rat. (13/232)

Laser irradiation is one of the therapeutic methods for the recovery of degenerated peripheral nerves. The aim of the present study was to determine if low-power laser treatment stimulates the regeneration process of damaged nerves. A standardized crush to the sciatic nerve was applied to cause extensive axonal degeneration. After this procedure, low-power infrared laser irradiation was administered transcutaneously to the injured sciatic nerve, 3 minutes daily to each of four treatment groups for 1, 3, 5 and 7 weeks, respectively. A nerve conduction study was done, and a morphological assessment was performed using both light and electron microscopy. With trauma of the nerve, both amplitude of compound motor action potential and nerve conduction velocity decreased significantly compared to the pre-trauma state. Morphologically, the numbers of myelinated axons and degenerated axons were decreased and increased, respectively, compared with the control. Typical aspects were of onion skin-type lamellation, fragmentation, edematous swelling and rarefaction in the myelin sheath. All these parameters recovered almost to the level of the pre-trauma state with laser irradiation, in direct proportion to the time spent for treatment. These results suggest that low-power infrared laser irradiation can relieve the mechanical damage of sciatic nerves and stimulate the regeneration of peripheral nerves.  (+info)

Effect of low-level laser therapy on osteoarthropathy in rabbit. (14/232)

The aim of this study was to determine whether low-level laser therapy (LLLT) aided the recovery of damaged articular cartilage in joints with artificially induced osteoarthropathy (OA). OA was induced by injecting hydrogen peroxide (H2O2) into the articular spaces of both knees in rabbits, twice a week for 4 weeks. The induction of OA and the effect of LLLT were evaluated by biochemical, radiological and histopathological analysis. Superoxide dismutase (SOD) activity increased about 40% in the OA group, as compared to the controls. Although SOD activity in the OA group was not significantly different from the 2-week groups, it was significantly different from the 4-week control and treatment groups. There was also a significant difference between the 4-week control and treatment groups. Simple radiographs and three-dimensional computed tomographs (3D CT) did not show detectable arthropathy in the OA group, nor any particular changes in the 2-week groups. In contrast, distinct erosions were seen in the distal articular cartilage of the femur, with irregularity of the articular surface, in the 4-week control group, while the erosions were reduced and arthropathy improved slightly in the 4-week treatment group. Grossly, erosions formed on the articular surface in the OA group. In comparison, severe erosions damaged the articular cartilage in the 4-week control group, but not in the 2-week control and treatment groups. Regeneration of articular cartilage was seen in gross observations in the 4-week treatment group. Histopathologically, there was slight irregularity of the articular surface and necrosis in the OA group, and serious cartilage damage, despite slight chondrocyte regeneration, in the 4-week control group. Conversely, the 4-week treatment group showed chondrocyte replacement, with sometimes close to normal articular cartilage on the articular surface. These results suggest that LLLT was effective in the treatment of chemically-induced OA.  (+info)

Design and testing of low intensity laser biostimulator. (15/232)

BACKGROUND: The non-invasive nature of laser biostimulation has made lasers an attractive alternative in Medical Acupuncture at the last 25 years. However, there is still an uncertainty as to whether they work or their effect is just placebo. Although a plethora of scientific papers published about the topic showing positive clinical results, there is still a lack of objective scientific proofs about the biostimulation effect of lasers in Medical Acupuncture. The objective of this work was to design and build a low cost portable laser device for stimulation of acupuncture points, considered here as small localized biosources (SLB), without stimulating any sensory nerves via shock or heat and to find out a suitable method for objectively evaluating its stimulating effect. The design is aimed for studying SLB potentials provoked by laser stimulus, in search for objective proofs of the biostimulation effect of lasers used in Medical Acupuncture. METHODS: The proposed biostimulator features two operational modes: program mode and stimulation mode and two output polarization modes: linearly and circularly polarized laser emission. In program mode, different user-defined stimulation protocols can be created and memorized. The laser output can be either continuous or pulse modulated. Each stimulation session consists of a pre-defined number of successive continuous or square pulse modulated sequences of laser emission. The variable parameters of the laser output are: average output power, pulse width, pulse period, and continuous or pulsed sequence duration and repetition period. In stimulation mode the stimulus is automatically applied according to the pre-programmed protocol. The laser source is 30 mW AlGaInP laser diode with an emission wavelength of 685 nm, driven by a highly integrated driver. The optical system designed for beam collimation and polarization change uses single collimating lens with large numerical aperture, linear polarizer and a quarter-wave retardation plate. The proposed method for testing the device efficiency employs a biofeedback from the subject by recording the biopotentials evoked by the laser stimulus at related distant SLB sites. Therefore measuring of SLB biopotentials caused by the stimulus would indicate that a biopotential has been evoked at the irradiated site and has propagated to the measurement sites, rather than being caused by local changes of the electrical skin conductivity. RESULTS: A prototype device was built according to the proposed design using relatively inexpensive and commercially available components. The laser output can be pulse modulated from 0.1 to 1000 Hz with a duty factor from 10 to 90%. The average output power density can be adjusted in the range 24-480 mW/cm2, where the total irradiation is limited to 2 Joule per stimulation session. The device is controlled by an 8-bit RISC Flash microcontroller with internal RAM and EEPROM memory, which allows for a wide range of different stimulation protocols to be implemented and memorized. The integrated laser diode driver with its onboard light power control loop provides safe and consistent laser modulation. The prototype was tested on the right Tri-Heater (TH) acupuncture meridian according to the proposed method. Laser evoked potentials were recorded from most of the easily accessible SLB along the meridian under study. They appear like periodical spikes with a repetition rate from 0.05 to 10 Hz and amplitude range 0.1-1 mV. CONCLUSION: The prototype's specifications were found to be better or comparable to those of other existing devices. It features low component count, small size and low power consumption. Because of the low power levels used the possibility of sensory nerve stimulation via the phenomenon of shock or heat is excluded. Thus senseless optical stimulation is achieved. The optical system presented offers simple and cost effective way for beam collimation and polarization change. The novel method proposed for testing the device efficiency allows for objectively recording of SLB potentials evoked by laser stimulus. Based on the biopotential records obtained with this method, a scientifically based conclusion can be drawn about the effectiveness of the commercially available devices for low-level laser therapy used in Medical Acupuncture. The prototype tests showed that with the biostimulator presented, SLB could be effectively stimulated at low power levels. However more studies are needed to derive a general conclusion about the SLB biostimulation mechanism of lasers and their most effective power and optical settings.  (+info)

Laser therapy in the treatment of dentine hypersensitivity. (16/232)

Cervical dentine hypersensitivity is the most frequent complaint among reported odontalgias. Thus, this study evaluated the effectiveness of two types of lasers (660 nm wavelength red, and 830 nm wavelength infrared) as dentine desensitizers, as well as both the immediate and late therapeutic effects in individuals 25 to 45 years of age. A total of 40 teeth with cervical exposure were treated in 4 sessions. They were divided into 2 groups according to treatment. A 660 nm wavelength red diode laser and an 830 nm wavelength infrared diode laser were used. Dentine sensitivity to cold nociceptive stimulus was evaluated by means of a pain numeric scale from zero to 10 before each treatment session, at 15 and 30 min after irradiation, and in a follow-up period of 15, 30 and 60 days after the end of treatment. Significant levels of dentinal desensitization were only found in patients ranging in age from 25 to 35 years. The 660 nm red diode laser was more effective than the 830 nm infrared laser and a higher level of desensitization was observed at the 15 and 30 minute post-irradiation examinations. The immediate and late therapeutic effects of the 660 nm red diode laser were more evident in 25-35-year-old patients compared with those of the 830 nm infrared diode laser, in terms of the different age groups.  (+info)