Histopathological and microanalytical study of zirconium dioxide and barium sulphate in bone cement. (65/937)

AIMS: To report the appearances of zirconium dioxide and barium sulphate in interface membranes, synovium, and other tissues around joint prostheses. METHODS: Histological sections from 23 specimens were reviewed by light microscopy and polarisation. Scanning electron microscopy and x ray microanalysis were performed on routinely processed paraffin wax sections. RESULTS: Polyethylene, metals, and polymethylmethacrylate cement debris were easily recognisable. Almost all the cement remnants contained either zirconium dioxide or barium sulphate, confirmed by microanalysis. The contrast media had characteristic light microscopic appearances. Zirconium was identified in macrophages away from cement remnants. CONCLUSION: The presence of radiographic contrast media in tissues around prosthetic joints is common but not widely recognised.  (+info)

Fixation of a hydroxyapatite-tricalcium phosphate-coated cementless knee prosthesis. Clinical and radiographic evaluation seven years after surgery. (66/937)

Miller-Galante II total knee arthroplasty (MG II TKA) was performed on 32 knees in 30 patients. On both the femoral and tibial components, the fibre-metal area was plasma-sprayed with hydroxyapatite-tricalcium phosphate (HA-TCP). The clinical and radiographic outcome was evaluated. A mean preoperative knee score of 26.0 +/- 18.6 (SD) increased to 97.5 +/- 3.5 and a mean pre-operative functional score of 21.7 +/- 15.0 (SD) increased to 83.4 +/- 12.4 at follow-up of seven years. Clear zones were common around the components at one month post-operatively but had completely disappeared after six months. An autopsy of a patient who underwent MG II TKA with HA-TCP two years previously, showed osteogenesis in all parts of the fibre-metal, and bone tissue comprised 77.7% of the interface. This coated prosthesis has good early fixation which is maintained at seven years with good clinical and radiographic outcomes.  (+info)

Beneficial effects of continuous passive motion after total condylar knee arthroplasty. (67/937)

A randomised, controlled study of the use of postoperative continuous passive motion (CPM) and immobilisation regimen after total condylar knee arthroplasty was performed. CPM resulted in a significant increase in both the early and late range of knee flexion. This increase occurred in both rheumatoid and osteoarthritic patients. The improvement of 10 degrees at 12 months allowed additional important function to be attained. CPM resulted in significantly earlier discharge from hospital. It did not increase the clinical incidence of wound healing problems, nor did it significantly increase the postoperative fixed flexion deformity or the extension lag. CPM can be recommended as a safe and effective modality to achieve more rapid and more successful postoperative rehabilitation after knee arthroplasty.  (+info)

Arthroscopic debridement in the treatment of the infected total knee replacement. (68/937)

Infection is a potentially disastrous complication of total knee replacement (TKR). Retention of the prosthesis has been associated with high rates of persistent infection. Our study shows that in selected situations, arthroscopic debridement may allow retention of the prosthesis and eradication of the infection. However, the prosthesis must be stable, the surgical technique must be meticulous and specific antibiotics must be taken for a lengthy period. Arthroscopic debridement should be considered as an alternative to an open technique, or revision, for the infected TKR.  (+info)

Intra-operative findings in varus osteoarthritis of the knee. An analysis of pre-operative alignment in potential candidates for unicompartmental arthroplasty. (69/937)

Interest in unicompartmental knee arthroplasty (UKA) for the treatment of medial compartment osteoarthritis has increased in recent years with apparent improvement in the long-term results. This is a result of improved surgical technique, patient selection, and implant design. In an effort further to improve patient selection we analysed the relationship between the pre-operative alignment of the knee and the anatomical findings at the time of surgery. We compared these findings with the indications for UKA. From 4021 total knee arthroplasties we compared intra-operative observations with the pre-operative clinical data in order to identify knees with isolated, medial, compartment changes, which would have been ideal candidates for UKA. We found that only 247 of the knees (6.1%) met anatomical qualifications for isolated, medial, unicompartmental osteoarthritis, and of these, only 168 (4.3%) met clinical standards ideal for UKA. Preoperative alignment showed a significant relationship with patterns of disease. Logistic regression revealed a relationship between pre-operative alignment and intraoperative findings resembling a Gaussian distribution. Patients with a pre-operative varus alignment of 7 degrees were slightly more likely to be selected for UKA. But the further the anatomical alignment in either direction varies from 7 degrees of varus, the more unlikely it is for the knee to exhibit a disease pattern of isolated, medial, unicompartmental osteoarthritis.  (+info)

99mTc-HMPAO-leukocyte scintigraphy in patients with symptomatic total hip or knee arthroplasty: improved diagnostic accuracy by means of semiquantitative evaluation. (70/937)

The aim of this study was to evaluate the diagnostic value, in suspected infectious prostheses, of (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) leukocyte scintigraphy interpreted with the addition of a semiquantitative analysis. METHODS: By means of a retrospective review, we included a group of 78 consecutive patients with suspected hip or knee prosthesis infection. We performed 91 (99m)Tc-HMPAO-leukocyte scintigraphies and examined 95 localizations that were suspect. Images were acquired at 3 different time points after the injection of the labeled leukocytes: 50 min (early images), 4 h, and 24 h (late images). The scintigraphic examinations were independently evaluated by 3 observers; qualitative and semiquantitative analyses were performed. The final diagnosis of infection was based on surgical, histologic, and bacteriologic data and follow-up. RESULTS: On qualitative analysis, sensitivity, specificity, and accuracy were 80.4%-87%, 65.3%-71.4%, and 75.8%-77.9%, respectively. On semiquantitative analysis, sensitivity, specificity, and accuracy were 95.6%, 95.8%, and 95.8%, respectively. The analysis of 95% confidential intervals showed statistically significant differences in specificity and accuracy between semiquantitative and qualitative analyses. CONCLUSION: In those patients who underwent (99m)Tc-HMPAO-leukocyte scintigraphy for suspected hip or knee prosthesis infection, the addition of a semiquantitative evaluation to the qualitative analysis of early and late images leads to a significant improvement in both specificity and accuracy.  (+info)

Antibiotic-loaded bone cement spacers in two-stage management of infected total knee arthroplasty. (71/937)

We reviewed the current use of spacers in the management of the infected knee prosthesis. There are two types of temporary spacers: block or non-articulating spacers and articulating or mobile spacers. Generally, spacers improve mobilisation and hasten recovery with shorter hospital stay between stages. Furthermore, spacers facilitate the second-stage procedure by maintaining joint space, and articulating spacers may also maintain range of motion. Last but not the least, the cost of spacers represents only a small fraction of the total expenses for management of infected knee arthroplasties.  (+info)

The fate of augments to treat type-2 bone defects in revision knee arthroplasty. (72/937)

We report the five- to-ten year results of Anderson Orthopaedic Research Institute type-2 bone defects treated with modular metal augments in revision knee surgery. A total of 102 revision knee arthroplasties in patients with type-2 defects treated with augments and stems were prospectively studied. Seven patients (seven knees) had incomplete follow-up and 15 patients (16 knees) died with the arthroplasty in situ. The mean follow-up of the 79 remaining knees was 7 +/- 2 years (5 to 11). The presence of non-progressive radiolucent lines around the augment in 14% of knees was not associated with poorer knee scores, the range of movement, survival of the component or the type of insert which was used (p > 0.05). The survival of the components was 92 +/- 0.03% at 11 years (95% CI, 10.3 to 11.2). We recommend the use of modular augmentation devices to treat type-2 defects in revision knee surgery.  (+info)