Individual rooms in the NICU - an evolving concept. (17/130)

The provision of individual rooms for NICU patients has several attractive benefits, including the ability to provide the appropriate environmental stimuli for each child, and increased privacy and accessibility for families. This concept can put serious strain on caregivers, however, by isolating them from one another and from the multiple infants for whom they may have responsibility, and places additional financial and space demands on the institution. These problems are not insurmountable, however, and use of individual rooms for at least some patients is feasible and probably desirable if certain considerations are addressed in the planning and design process.  (+info)

Ergonomic study on the manual component insertion lines for occupational health and safety improvements. (18/130)

The study aimed at reducing the occupational health and safety problems faced by the manual component insertion operators. Subjective and objective assessments, and direct observations were made in the printed circuit assembly factory. Simple and low-cost ergonomic interventions were implemented, that is, repairing chairs, reducing high workloads, assigning operators to a maximum of 2 workstations, confining machines that emitted bad smell and much noise, and providing finger work aids. The results of the interventions were reductions in operators' work discomforts, that is, chair discomfort (by 90%), high work stress, and discomfort due to profound change in their workstations. Their health hazards were also eliminated, that is, inhalation of toxic fumes, exposure to too much noise, and pain due to pressing sharp components.  (+info)

The application of a multisensory Snoezelen room for people with learning disabilities-Hong Kong experience. (19/130)

In recent years there has been a considerable increase in the use of complementary therapies in the field of learning disabilities. This paper describes the use of a Snoezelen (multisensory) room for adults with learning disabilities in a psychiatric setting in Hong Kong. Theoretical and operational issues are discussed. The demographic and clinical data of a cohort of 96 patients who had used the room were reviewed. Rating forms were completed by their carers or staff at the end of the course to provide a subjective evaluation of the effectiveness of treatment. This is followed by three case reports. In view of the rising popularity of the multisensory room for people with learning disabilities, more research of the impact and therapeutic values is recommended.  (+info)

The work environment and workers' health in four large office buildings. (20/130)

We conducted a 1-year epidemiologic study in Boston, Massachusetts, beginning May 1997, to examine the associations between environmental factors and office workers' health. We recruited 98 subjects (81 females and 17 males) in 21 offices in four office buildings. We conducted environmental sampling every 6 weeks and concurrently administered detailed questionnaires to collect information on work-related symptoms, psychosocial factors, and perceptions of the office environments. In multivariate analyses, eye irritation was positively correlated with floor dust [odds ratio (OR) = 1.46; 95% confidence intervals (CI), 1.14-1.86] and reported lack of office cleanliness (OR = 1.52; 95% CI, 1.11-2.08). Nonspecific symptoms were positively associated with unidentified chair fungi (OR = 1.87; 95% CI, 1.11-3.15) and several self-reported conditions, including a history of asthma (OR = 3.15; 95% CI, 1.26-7.87), more people in offices (OR = 1.71; 95% CI, 1.16-2.51), lack of office cleanliness (OR = 2.85; 95% CI, 1.72-4.73), and low job satisfaction (OR = 1.72; 95% CI, 1.06-2.81). Upper respiratory symptoms were positively associated with total fungal concentrations recovered from chair dust (OR = 1.35; 95% CI, 1.07-1.70) and the following self-reported conditions: more people in offices (OR = 1.45; 95% CI, 1.01-2.08), lack of office cleanliness (OR = 1.62; 95% CI, 1.15-2.30), and jobs frequently requiring hard work (OR = 1.43; 95% CI, 1.05-1.95). This study emphasizes the importance of maintaining a clean, uncrowded workspace and the importance of chair fungi as a correlate for health effects.  (+info)

Evidence-based ergonomics. A comparison of Japanese and American office layouts. (21/130)

There is a variety of alternatives in office layouts. Yet the theoretical basis and criteria for predicting how well these layouts accommodate employees are poorly understood. The objective of this study was to evaluate criteria for selecting office layouts. Intensive computer workers worked in simulated office layouts in a controlled experimental laboratory. Eye movement measures indicate that knowledge work requires both concentration and interaction. Findings pointed to one layout as providing optimum balance between these 2 requirements. Recommendations for establishing a theoretical basis and design criteria for selecting office layouts based on work style are suggested.  (+info)

Asthma, wheezing, and allergies in Russian schoolchildren in relation to new surface materials in the home. (22/130)

In a cross-sectional study of 5951 Russian 8-12-year-old schoolchildren, risks of current asthma, wheezing, and allergy were related to recent renovation and the installation of materials with potential chemical emissions. New linoleum flooring, synthetic carpeting, particleboard, wall coverings, and furniture and recent painting were determinants of 1 or several of these 3 health outcomes. These findings warrant further attention to the type of materials used in interior design.  (+info)

Respiratory symptoms and peak expiratory flow rates among furniture-decoration students. (23/130)

This study was designed to evaluate the effects of furniture production, mainly including fir tree (aberia mulleriana), on respiratory health of young workers and to compare the results with those obtained from previous studies. Sixty-four furniture-decoration students (57 males and 7 females) and 62 controls (54 male, 8 female) from different departments in the same school were included into the study. All participants were assessed with a questionnaire (concerning history of occupational exposure, work-related respiratory and other symptoms, smoking history, previous asthma history), full physical examination, spirometric evaluation and chest radiograph. Participants then performed serial monitoring of peak expiratory flow rates (PEFR) at work and away from work within a month. Mean age of students was 20.9 +/- 3.7 years, 20.5 +/- 2.6 years in controls. There was no difference between study and control groups with regard to age, gender, smoking status and previous asthma history. Reported cough (23.4 % vs. 8.1 %) and shortness of breath (18.8 % vs. 6.5 %) were significantly higher in furniture-decoration students than in controls (p = 0.016 and p = 0.034, respectively). Furniture-decoration students had higher conjunctivitis (34.4 % vs. 9.7 %, p = 0.001) and rhinitis (34.4 % vs. 19.4 %, p = 0.044) history when compared with controls. Both students and controls were normal in terms of respiratory examination. PEF recordings were performed for approximately one month. Diurnal variability greater than 20 % was seen in 12/64 (18.7 %) of students at work, whereas it was detected in 4/62 (6.4 %) of controls (p = 0.034). When comparing for the presence of diurnal variability greater than 20 % in weekends, no difference was found between groups (p = 0.457). In conclusion, early detection of work-related respiratory changes by serial monitoring of peak expiratory flows should save the workers from hazardous respiratory effects of the furniture production, especially in young population.  (+info)

Determination of the efficacy of two building decontamination strategies by surface sampling with culture and quantitative PCR analysis. (24/130)

The efficacy of currently available decontamination strategies for the treatment of indoor furnishings contaminated with bioterrorism agents is poorly understood. Efficacy testing of decontamination products in a controlled environment is needed to ensure that effective methods are used to decontaminate domestic and workplace settings. An experimental room supplied with materials used in office furnishings (i.e., wood laminate, painted metal, and vinyl tile) was used with controlled dry aerosol releases of endospores of Bacillus atrophaeus ("Bacillus subtilis subsp. niger," also referred to as BG), a Bacillus anthracis surrogate. Studies were performed using two test products, a foam decontaminant and chlorine dioxide gas. Surface samples were collected pre- and posttreatment with three sampling methods and analyzed by culture and quantitative PCR (QPCR). Additional aerosol releases with environmental background present on the surface materials were also conducted to determine if there was any interference with decontamination or sample analysis. Culture results indicated that 10(5) to 10(6) CFU per sample were present on surfaces before decontamination. After decontamination with the foam, no culturable B. atrophaeus spores were detected. After decontamination with chlorine dioxide gas, no culturable B. atrophaeus was detected in 24 of 27 samples (89%). However, QPCR analysis showed that B. atrophaeus DNA was still present after decontamination with both methods. Environmental background material had no apparent effect on decontamination, but inhibition of the QPCR assay was observed. These results demonstrate the effectiveness of two decontamination methods and illustrate the utility of surface sampling and QPCR analysis for the evaluation of decontamination strategies.  (+info)