Intrapericardial delivery of gelfoam enables the targeted delivery of Periostin peptide after myocardial infarction by inducing fibrin clot formation. (65/97)

 (+info)

Open partial splenectomy for trauma using GIA-Stapler and FloSeal matrix haemostatic agent. (66/97)

 (+info)

Safety trial of Floseal((R)) haemostatic agent in head and neck surgery. (67/97)

 (+info)

Synthetic hydrogel scaffold is an effective vehicle for delivery of INFUSE (rhBMP2) to critical-sized calvaria bone defects in rats. (68/97)

 (+info)

Roles played by chemolipiodolization and embolization in chemoembolization for hepatocellular carcinoma: single-blind, randomized trial. (69/97)

 (+info)

Evaluation of the efficacy of bupivacaine soaked in Gelfoam((R)) at the iliac crest bone graft site. (70/97)

 (+info)

Effect of thrombin concentration on the adhesion strength and clinical application of fibrin glue-soaked sponge. (71/97)

Fibrin glue-soaked gelatin sponge (FGGS) has been used for tissue sealing in neurosurgical practice, but too rapid clotting of fibrin glue occasionally prevents good fixation of FGGS. Dilution of thrombin may provide adequate manipulation time between mixing fibrinogen and thrombin on gelatin sponge and application into the tissue defects. The present study characterized the effect of thrombin dilution on the adhesion strength of FGGS and retrospectively assessed the clinical usage of the dilution for filling dead space or sealing arachnoid defect in 255 cases who underwent transsphenoidal surgery for the last 66 months. FGGS was prepared using three different concentrations of thrombin: 250 (standard), 50 (1:5 dilution), and 25 (1:10 dilution) units/ml, and incubated for three different periods (5, 20, and 60 seconds). FGGSs were applied over two adjacently positioned porcine skins placed on two metallic plates. The adhesion strength was evaluated by measuring maximum tensile strength during pulling out the sliding plate at a constant rate of displacement. The maximum adhesion strength was greater for FGGS with 1:10 diluted thrombin solution than for FGGS prepared with higher concentrations (p < 0.05). Adhesion strength did not decay for 20 seconds after the mixture. Only four of 255 cases (1.6%) required second reconstruction of sella floor due to the cerebrospinal fluid leakage. FGGS prepared with diluted thrombin solution can provide adequate adhesion strength for clinical use.  (+info)

Comparison of two gelatin and thrombin combination hemostats in a porcine liver abrasion model. (72/97)

 (+info)