A meta-analysis of the literature on distal radius fractures: review of 615 articles. (57/342)

A structured meta-analysis of the available literature was performed to evaluate the outcome of the treatment of displaced intra-articular fractures of the distal radius. A comprehensive search of Medline using the key words "radius" and "fracture" revealed over 4,000 articles. After limiting the search to clinical trials in English and excluding pediatric and geriatric age groups as well as biomechanical and animal studies, 615 abstracts were identified in the period from 1976 to May 1998. Thirty-one articles met the inclusion and exclusion criteria. These included two prospective randomized comparative trials, two non-randomized comparative trials, one half prospective case series and half historical control, and 27 papers on case series. Four papers dealt with external fixation versus closed reduction and cast treatment and one paper looked at open reduction internal fixation with or without additional external fixation. There was insufficient data to perform a scientific meta-analysis because of the poor quality of the studies and lack of a uniform method of outcome assessment. However, the data from the comparative trials showed that external fixation was favored over closed reduction and casting. Additionally, comparing the results of the case series showed that external fixation was superior to internal fixation.  (+info)

Staged management of high-energy proximal tibia fractures. (58/342)

High-energy proximal tibia fractures are complicated by soft tissue compromise and this may result in sub-optimal outcomes. There is a high association of open injuries, compartment syndromes, and vascular injuries with these bony disruptions. Surgical treatment of these injuries has been associated with significant complications such as infection, knee stiffness, malunion, loss of fixation, soft tissue failure, and amputations. The loss of fixation is an issue especially in the elderly, with failure associated with age more than sixty years, premature weight bearing, preoperative displacement, fracture fragmentation, and severe osteoporosis. The use of two-stage reconstruction for the treatment of distal tibia fractures has been successful in decreasing the complication rates, including wound compromise. The two stages involve: 1. stabilization of the injured limb with a bridging external fixator to allow the soft tissues to improve and recover and 2. definitive fixation for reconstruction of the articular surface and meta-diaphyseal fractures. The use of such a protocol has been proposed for high-energy proximal tibia fractures to decrease the high rate of soft tissue compromise associated with traditional open methods of treatment. The choice of definitive fixation may include plates, nails, or non-bridging external fixation.  (+info)

Unilateral congenital elbow luxation in a Cavalier King Charles Spaniel. (59/342)

A 7-week-old, intact female, Cavalier King Charles Spaniel was evaluated for nonweight bearing lameness of the right forelimb. Type III unilateral congenital elbow luxation was diagnosed radiographically. After surgical reduction, temporary placement of a transarticular pin, and external splinting of the joint, full weight bearing was achieved. Radial head subluxation persisted.  (+info)

Fixation methods for implantable port chamber: comparative study using glue, self-stabilizing leg and suture fixations in rabbits. (60/342)

OBJECTIVE: To evaluate the fixation strength and tissue reaction of the glue fixation and self-stabilizing leg fixation methods and to compare the results with those of the conventional tagging suture fixation method. MATERIALS AND METHODS: Twelve healthy rabbits were selected and three different methods of implanting the port chamber were employed on the back of each rabbit. A total of thirty six port chambers were implanted with these three different methods, viz. the glue fixation method using tissue adhesive, the self-stabilizing leg method using a self-expandable stabilizing leg, and the suture fixation method. The fixation strength and the gross and histopathologic changes of each fixation method were evaluated at three days, one week, two weeks and four weeks after port implantation. RESULTS: The glue fixation method showed a good fixation strength, which was similar to that of the tagging suture method (p = 0.3486). Five of the six ports (83%) implanted with the glue fixation method which were examined after two weeks showed cracks on the external surface, but this had no adverse effects on their function. A large amount of granulation tissue reaction was found at the bottom of the chamber (p = 0.0025). The fixation with the self-stabilizing leg showed relatively lower fixation strength (p = 0.0043), but no turning-over of the chamber occurred. The fixation strength improved with time after the first week, and minimal granulation tissue reaction was observed with this method. CONCLUSION: The glue fixation method exhibited equal fixation strength compared to the suture fixation, but showed cracking and a large amount of granulation tissue, whereas the fixation with a self-stabilizing leg showed weaker fixation strength.  (+info)

Nonbridging external fixation for fractures of the distal radius. (61/342)

OBJECTIVE: To assess the feasibility of using standard components from the small AO external fixator set to support fractures of the distal radius with a construct incorporating distal fixation in the periarticular radius fragment that would allow for primary mobilization of the wrist joint during fracture healing. METHODS: In a prospective pilot study of a nonbridging external fixator in early 2001, 6 consecutive cases of fracture in the distal radius presenting at a tertiary care centre, the Hamilton General Division of Hamilton Health Sciences, were compared with 6 historical controls treated with a standard bridging construct immobilizing the wrist. Both groups were or had been treated with closed reduction and external fixation of the distal radius under fluoroscopic control. Fracture alignment was measured on radiographs after healing and removal of the fixation devices; additional (secondary) outcome measures were pin-tract sepsis and implant loosening (treatment failure). RESULTS: Compared radiographically with controls, alignments after fracture healing were improved (and virtually anatomic) with use of the nonbridging external fixator. The incidence of pin-tract sepsis was similar in the 2 groups, neither of which included any treatment failures. CONCLUSIONS: Nonbridging external fixation of comminuted distal radius fractures can be accomplished safely and effectively. The results of this pilot study suggest that improved radiographic alignment may be achieved with this technique.  (+info)

Complex tibial plateau fractures treated with Ilizarov external fixator with or without minimal internal fixation. (62/342)

We treated 30 tibial plateau fractures (Schatzker Type VI) in 29 patients, with a mean age of 41.4 (20-76) years, with the Ilizarov fixator. In 18 fractures, we combined the treatment with minimal internal fixation. All fractures were the result of high-energy trauma, and 20 patients had associated injuries. Twenty-eight fractures were available for follow-up after 27 (16-36) months. Using The Knee Society clinical rating system, 18 knees were rated as excellent, seven as good, one as fair, and two as poor. There was a direct correlation between the presence of associated injuries and the final outcome. The most significant concomitant injuries were distal femoral fractures and extensive soft-tissue injury. This study emphasizes the clinical success and low morbidity associated with the use of external fixation and minimal internal fixation.  (+info)

Primary stability of various forms of osteosynthesis in the treatment of fractures of the proximal tibia. (63/342)

The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the LISS was better than the buttress plate. In summary, it was found that higher loads were better tolerated by centrally placed load carriers than by eccentrically placed ones. In the case of the latter, it appears advantageous to use additive procedures for medial buttressing in the early phase.  (+info)

A 2-year prospective study of patient-relevant outcomes in patients operated on for knee osteoarthritis with tibial osteotomy. (64/342)

BACKGROUND: Tibial osteotomy is a treatment for younger and/or physically active patients suffering from uni-compartmental knee osteoarthritis. The open wedge osteotomy by the hemicallotasis technique includes the use of external fixation. The use of external fixation has several advantages, as early mobilization and the opportunity for optimal correction. However, the hemicallotasis technique has also been described as a cumbersome procedure for the patient. The aim of this study was to prospectively evaluate patient-relevant outcomes during the first 2 post-operative years. Especially the treatment period, during which external fixation was used, was closely monitored. METHODS: In an uncontrolled study, fifty-eight consecutive patients, 30 men and 28 women (mean age 54 years) were operated on by the hemicallotasis technique were evaluated with the patient-relevant outcome measure Knee injury and Osteoarthritis Outcome Score (KOOS) preoperatively, during the treatment with external fixation, one week after removal of the external fixation, at 6 months, and at one and two years postoperatively. RESULTS: At the 2-year postoperative follow-up, all subscales of the KOOS were improved (p < 0.001), mostly in pain (41-80 on a 0-100 worst to best scale) and knee-related quality of life (21-61 on a 0-100 worst to best scale), compared to the preoperative status. Significant improvements in pain and other symptoms, function of daily life and quality of life were seen already during the treatment period (mean 98 +/- 18 days) with the external fixation. More demanding functions such as kneeling, squatting, jumping and running, were improved first after extraction of the external fixation device and the pins. CONCLUSION: Tibial osteotomy by the hemicallotasis technique yields large improvement in self-rated pain, function and quality of life, which persists over two years. Surprisingly, large improvements occurred already during the immediate post-operative period when the external fixation was still used.  (+info)