Sedation depth during spinal anesthesia and the development of postoperative delirium in elderly patients undergoing hip fracture repair. (17/74)

 (+info)

Correlation between bispectoral index and predicted effect-site concentration of propofol in different levels of target-controlled, propofol induced sedation in healthy volunteers. (18/74)

INRODUCTION: Bispectral Index is an objective tool to assess electroencephalographic activity and measure the effect of certain sedatives and hypnotics on the brain. In addition, there are certain subjective tools such as the observer's assessment of alertness and sedation which are used. The correlation between BIS and the concentration of propofol in the brain, and the relationship between these subjective and objective tools in assessing sedation levels are the subject of this study. METHODS: Thirty healthy volunteers enrolled in this prospective observational study. They were sedated with a target controlled infusion of propofol with an initial target of 0.8 microg.mL(-1)and an increase in target to 0.2 microg.mL(-1) ten minutes after equilibration of the predicted and set target concentrations. In each sedation score, the Bispectral Index value and predicted effect site concentration of propofol were recorded and analyzed. Analysis of variance and significant differences between groups were analyzed by paired t-test. Correlations between Bispectral Index and effect site concentration of propofol at each sedation score and the relationship of BIS and effect site concentration of propofol to each sedation score were assessed and analyzed by nonparametric Spearman's rho. RESULTS: The means of Bispectral Index and effect site concentration of propofol at each sedation score showed a significant difference with the following score. Additionally, Bispectral Index and effect site concentration of propofol showed a significant negative correlation in sedation scores 3 and 2 when inducing sedation. In other sedation scores or when reversing the sedation, no strong correlation was noted. CONCLUSION: Both Bispectral Index and effect site concentration of propofol indicate a good estimate of sedation levels; however their correlations are significant and negative only at moderate and deep sedation levels, and during the induction of sedation.  (+info)

Intensive Care Unit-acquired infection as a side effect of sedation. (19/74)

 (+info)

Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy. (20/74)

BACKGROUND: Pulse oximetry is a widely accepted procedure for ventilatory monitoring during gastrointestinal endoscopy, but this method provides an indirect measurement of the respiratory function. In addition, detection of abnormal ventilatory activity can be delayed, especially if supplemental oxygen is provided. Capnography offers continuous real-time measurement of expiratory carbon dioxide. OBJECTIVE: We aimed at prospectively examining the advantages of capnography over the standard pulse oximetry monitoring during sedated colonoscopies. PATIENTS AND METHODS: Fifty patients undergoing colonoscopy were simultaneously monitored with pulse oximetry and capnography by using two different devices in each patient. Several sedation regimens were administered. Episodes of apnea or hypoventilation detected by capnography were compared with the occurrence of hypoxemia. RESULTS: Twenty-nine episodes of disordered respiration occurred in 16 patients (mean duration 54.4 seconds). Only 38% of apnea or hypoventilation episodes were detected by pulse oximetry. A mean delay of 38.6 seconds was observed in the events detected by pulse oximetry (two episodes of disturbed ventilation were simultaneously detected by capnography and pulse oximetry). CONCLUSIONS: Apnea or hypoventilation commonly occurs during colonoscopy with sedation. Capnography is more reliable than pulse oximetry in early detection of respiratory depression in this setting.  (+info)

A systematic review of the impact of sedation practice in the ICU on resource use, costs and patient safety. (21/74)

 (+info)

Does level of sedation impact detection of advanced neoplasia? (22/74)

 (+info)

Detection of hypoventilation during deep sedation in patients undergoing ambulatory gynaecological hysteroscopy: a comparison between transcutaneous and nasal end-tidal carbon dioxide measurements. (23/74)

 (+info)

Practice characteristics among dental anesthesia providers in the United States. (24/74)

 (+info)