Screw versus suture fixation of Mitchell's osteotomy. A prospective, randomised study. (9/1294)

We studied prospectively 30 patients who had a Mitchell's osteotomy secured by either a suture followed by immobilisation in a plaster boot for six weeks, or by a cortical screw with early mobilisation. The mean time for return to social activities after fixation by a screw was 2.9 weeks and to work 4.9 weeks, which was significantly earlier than those who had stabilisation by a suture (5.7 and 8.7 weeks, respectively; p < 0.001). Use of a screw also produced a higher degree of patient satisfaction at six weeks, and an earlier return to wearing normal footwear. The improvement in forefoot scores was significantly greater after fixation by a screw at six weeks (p = 0.036) and three months (p = 0.024). At one year, two screws had been removed because of pain at the site of the screw head. Internal fixation of Mitchell's osteotomy by a screw allows the safe early mobilisation of patients and reduces the time required for convalescence.  (+info)

Treatment of thoracolumbar burst fractures without neurologic deficit by indirect reduction and posterior instrumentation: bisegmental stabilization with monosegmental fusion. (10/1294)

This study retrospectively reviews 20 sequential patients with thoracolumbar burst fractures without neurologic deficit. All patients were treated by indirect reduction, bisegmental posterior transpedicular instrumentation and monosegmental fusion. Clinical and radiological outcome was analyzed after an average follow-up of 6.4 years. Re-kyphosis of the entire segment including the cephaled disc was significant with loss of the entire postoperative correction over time. This did not influence the generally benign clinical outcome. Compared to its normal height the fused cephalad disc was reduced by 70% and the temporarily spanned caudal disc by 40%. Motion at the temporarily spanned segment could be detected in 11 patients at follow-up, with no relation to the clinical result. Posterior instrumentation of thoracolumbar burst fractures can initially reduce the segmental kyphosis completely. The loss of correction within the fractured vertebral body is small. However, disc space collapse leads to eventual complete loss of segmental reduction. Therefore, posterolateral fusion alone does not prevent disc space collapse. Nevertheless, clinical long-term results are favorable. However, if disc space collapse has to prevented, an interbody disc clearance and fusion is recommended.  (+info)

Rotational acetabular osteotomy using biodegradable internal fixation. (11/1294)

We used biodegradable poly-L-lactide screws in rotational acetabular osteotomy in 41 hips of 41 patients, and studied the complications after an average follow-up of 4.9 years (range 1.0-7.7 years). There were 39 females and 2 males, their average age at the time of the operation was 32 years (range 12-55 years). A small subcutaneous abscess appeared around the non-absorbable sutures in 2 patients after surgery. There was 1 case of thrombophlebitis and 1 of local dermatitis. The small subcutaneous abscess resolved after the removal of the suture material in the 2 cases, and the thrombophlebitis resolved with aspirin. The local dermatitis persisted but was cured by local steroid therapy over 5.8 years. The incidence of local dermatitis after the use of biodegradable implants should be further investigated.  (+info)

Safety of the limited open technique of bone-transfixing threaded-pin placement for external fixation of distal radial fractures: a cadaver study. (12/1294)

OBJECTIVE: To examine the safety of threaded-pin placement for fixation of distal radial fractures using a limited open approach. DESIGN: A cadaver study. METHODS: Four-millimetre Schanz threaded pins were inserted into the radius and 3-mm screw pins into the second metacarpal of 20 cadaver arms. Each threaded pin was inserted in the dorsoradial oblique plane through a limited open, 5- to 10-mm longitudinal incision. Open exploration of the threaded-pin sites was then carried out. OUTCOME MEASURES: Injury to nerves, muscles and tendons and the proximity of these structures to the threaded pins. RESULTS: There were no injuries to the extensor tendons, superficial radial or lateral antebrachial nerves of the forearm, or to the soft tissues overlying the metacarpal. The lateral antebrachial nerve was the closest nerve to the radial pins and a branch of the superficial radial nerve was closest to the metacarpal pins. The superficial radial nerve was not close to the radial pins. CONCLUSION: Limited open threaded-pin fixation of distal radial fractures in the dorsolateral plane appears to be safe.  (+info)

Arthroscopic reconstruction of the anterior cruciate ligament with patellar-tendon autograft and interference screw fixation. The results at seven years. (13/1294)

Deficiency of the anterior cruciate ligament (ACL) is a common disorder which can lead to changes in lifestyle. We followed 59 patients who had had arthroscopic reconstruction of the ACL using a central-third patellar-tendon autograft for seven years to assess the long-term effectiveness of recent advances in reconstruction of the ACL. The standard criteria for evaluation of the International Knee Documentation Committee, the Lysholm knee score and measurements using the KT 1000 arthrometer all showed satisfactory results. Deterioration in the clinical performance after seven years was associated with osteoarthritic changes and correlated with chronic ligament injuries and meniscectomy. There were three traumatic and three spontaneous ruptures. We believe that the procedure can be successful, but remain concerned about failure of the graft and osteoarthritis. The results raise questions about the best time to operate and suggest that early surgery may reduce the risk of osteoarthritis.  (+info)

The placement of lumbar pedicle screws using computerised stereotactic guidance. (14/1294)

Computer-assisted frameless stereotactic image guidance allows precise preoperative planning and intraoperative localisation of the image. It has been developed and tested in the laboratory. We evaluated the efficacy, clinical results and complications of placement of a pedicle screw in the lumbar spine using this technique. A total of 62 patients (28 men, 34 women) had lumbar decompression and spinal fusion with segmental pedicle screws. Postoperative CT scans were taken of 35 patients to investigate the placement of 330 screws. None showed penetration of the medial or inferior wall of a pedicle. Registration was carried out 66 times. The number of fiducial points used on each registration averaged 5.8 (4 to 7) The mean registration error was 0.75 mm (0.32 to 1.72). This technique provides a safe and reliable guide for placement of transpedicular screws in the lumbar spine.  (+info)

Financial justification for routine ultrasound screening of the neonatal hip. (15/1294)

We have analysed the patterns of management of developmental dysplasia of the hip (DDH) in Coventry over a period of 20 years during which three different screening policies were used. From 1976 to the end of 1985 we relied on clinical examination alone. The mean surgical cost for the treatment of DDH during this period was Pound Sterling 5110 per 1000 live births. This was reduced to Pound Sterling 3811 after the introduction of ultrasound for infants with known risk factors. Since June 1989 we have routinely scanned all infants at birth with a mean surgical cost of Pound Sterling 468 per 1000 live births. This reduction in cost is a result of the earlier detection of DDH with fewer children requiring surgery. In those who do, fewer and less invasive procedures are needed. The overall rate of treatment has not increased and regular review of patients managed in a Pavlik harness has allowed us to avoid the complication of avascular necrosis. When we add the cost of running the screening programme to the expense of treating the condition, the overall cost for the management of DDH is comparable for the different screening policies.  (+info)

Open MR imaging in spine surgery: experimental investigations and first clinical experiences. (16/1294)

INTRODUCTION: The latest open MRI technology allows to perform open and closed surgical procedures under real-time imaging. Before performing spinal trauma surgery preclinical examinations had to be done to evaluate the artifacts caused by the implants. METHODS: The MRT presented is a prototype developed by GE. Two vertically positioned magnetic coils are installed in an operation theater. By that means two surgeons are able to access the patient between the two coils. Numerous tests regarding the material of instruments and implants were necessary in advance. The specific size of the artifact depending on the pulse sequence and the positioning within the magnetic field had to be examined. RESULTS: The magnifying factors of the artifact in the spin echo sequence regarding titanium are between 1.7 and 3.2, depending on the direction of the magnetic vector. Regarding stainless steel they are between 8.4 and 8.5. In the gradient echo sequence the factors are between 7.5 and 7.7 for titanium and between 16.9 and 18.0 for stainless steel. The tip of an implant is imaged with an accuracy of 0 to 2 mm. Since September 1997 16 patients with unstable fractures of the thoracic and lumbar spine have been treated by dorsal instrumentation in the open MRI. Percutaneous insertion of the internal fixator has proven a successful minimally invasive procedure. The positioning of the screws in the pedicle is secure, the degree of indirect reduction of the posterior wall of the vertebral body can be imaged immediately. The diameter of the spinal canal can be determined in any plane. DISCUSSION AND CONCLUSION: The open MRI has proven useful in orthopedic and trauma surgery. The size and configuration of the artifacts caused by instruments and implants is predictable. Therefore exact positioning of the implants is achieved more easily. Dorsal instrumentation of unstable thoracolumbar fractures with a percutaneous technique has turned out safe and less traumatic under MR-imaging. Real-time imaging of soft tissue and bone in any plane improves security for the patient and allows the surgeon to work less invasively and more precisely.  (+info)