The summary of diabetes self-care activities measure: results from 7 studies and a revised scale. (25/768)

OBJECTIVE: To review reliability, validity, and normative data from 7 different studies, involving a total of 1,988 people with diabetes, and provide a revised version of the Summary of Diabetes Self-Care Activities (SDSCA) measure. RESEARCH DESIGN AND METHODS: The SDSCA measure is a brief self-report questionnaire of diabetes self-management that includes items assessing the following aspects of the diabetes regimen: general diet, specific diet, exercise, blood-glucose testing, foot care, and smoking. Normative data (means and SD), inter-item and test-retest reliability, correlations between the SDSCA subscales and a range of criterion measures, and sensitivity to change scores are presented for the 7 different studies (5 randomized interventions and 2 observational studies). RESULTS: Participants were typically older patients, having type 2 diabetes for a number of years, with a slight preponderance of women. The average inter-item correlations within scales were high (mean = 0.47), with the exception of specific diet; test-retest correlations were moderate (mean = 0.40). Correlations with other measures of diet and exercise generally supported the validity of the SDSCA subscales (mean = 0.23). CONCLUSIONS: There are numerous benefits from standardization of measures across studies. The SDSCA questionnaire is a brief yet reliable and valid self-report measure of diabetes self-management that is useful both for research and practice. The revised version and its scoring are presented, and the inclusion of this measure in studies of diabetes self-management is recommended when appropriate.  (+info)

A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. (26/768)

OBJECTIVE: The objectives of this study were 1) to construct new error grids (EGs) for blood glucose (BG) self-monitoring by using the expertise of a large panel of clinicians and 2) to use the new EGs to evaluate the accuracy of BG measurements made by patients. RESEARCH DESIGN AND METHODS: To construct new EGs for type 1 and type 2 diabetic patients, a total of 100 experts of diabetes were asked to assign any error in BG measurement to 1 of 5 risk categories. We used these EGs to evaluate the accuracy of self-monitoring of blood glucose (SMBG) levels in 152 diabetic patients. The SMBG data were used to compare the new type 1 diabetes EG with a traditional EG. RESULTS: Both the type 1 and type 2 diabetes EGs divide the risk plane into 8 concentric zones with no discontinuities. The new EGs are similar to each other, but they differ from the traditional EG in several significant ways. When used to evaluate a data set of measurements made by a sample of patients experienced in SMBG, the new type 1 diabetes EG rated 98.6% of their measurements as clinically acceptable, compared with 95% for the traditional EG. CONCLUSIONS: The consensus EGs furnish a new tool for evaluating errors in the measurement of BG for patients with type 1 and type 2 diabetes.  (+info)

Validation of a structured interview for the assessment of diabetes self-management. (27/768)

OBJECTIVE: The authors developed and validated a semi-structured interview; the Diabetes Self-Management Profile (DSMP), to measure self-management of type 1 diabetes. The DSMP includes the following regimen components: exercise, management of hypoglycemia, diet, blood glucose testing, and insulin administration and dose adjustment. RESEARCH DESIGN AND METHODS: Families of youths with type 1 diabetes (n = 105) who were entering a controlled trial of intensive therapy (IT) versus usual care (UC) were administered the DSMP Analyses assessed the reliability and validity of the DSMP, including its associations with HbA1c and quality of life. RESULTS: The DSMP total score has adequate internal consistency (Cronbach's alpha 0.76), 3-month test-retest reliability (Pearson correlation, r = 0.67), inter-interviewer agreement (r = 0.94), and parent-adolescent agreement (r = 0.61). DSMP total scores (r = -0.28) and 3 subscales correlated significantly with HbA1c (diet [r = -0.27], blood glucose testing [r = -0.37], and insulin administration and dose adjustment [r = -0.25 ]). Adolescents' reports of self-management did not differ from parental reports. Higher DSMP scores were associated with more favorable quality of life for mothers and youths. CONCLUSIONS: The DSMP is a convenient measure that yields a reliable and valid assessment of diabetes self-management. Compared with extant similar measures, the DSMP is more strongly correlated with HbA1c.  (+info)

Diabetes-related emotional distress in Dutch and U.S. diabetic patients: cross-cultural validity of the problem areas in diabetes scale. (28/768)

OBJECTIVE: To examine the cross-cultural validity of the Problem Areas in Diabetes Scale (PAID) in Dutch and U.S. diabetic patients. RESEARCH DESIGN AND METHODS: A total of 1,472 Dutch people with diabetes completed the PAID along with other self-report measures of affect. Statistics covered Cronbach's alpha, exploratory factor analysis (EFA), and confirmatory factor analysis (CFA), Pearson's product-moment correlation, and t tests. Psychometric properties of PAID were compared for Dutch and U.S. diabetic patients. RESULTS: Internal consistency of the Dutch PAID was high and stable across sex and type of diabetes. Test-retest reliability was high. Principal component analyses confirmed 1 general 20-item factor, whereas EFA identified 4 new subdimensions: negative emotions, treatment problems, food-related problems, and lack of social support. These dimensions were confirmed with CFA and were replicated in the U.S. sample. The PAID and its subscales demonstrated moderate to high associations in the expected direction with other measures of affect. Dutch and U.S. subjects reported having the same problem areas, with U.S. patients reporting higher emotional distress levels both in type 1 and type 2 diabetes. CONCLUSIONS: The Dutch and U.S. 20-item PAID appeared to be psychometrically equivalent, which allowed for cross-cultural comparisons.  (+info)

Personality correlates of glycemic control in type 2 diabetes. (29/768)

OBJECTIVE: To determine whether traits of normal personality are associated with variations in glycemic control in patients with type 2 diabetes. RESEARCH DESIGN AND METHODS: A longitudinal cohort study was conducted using data from 105 type 2 diabetic patients in a clinical trial of a stress management intervention. Before treatment assignment, patients completed the NEO Personality Inventory, Revised, which is a questionnaire inventory measuring 5 major domains of normal personality and 30 important traits that define these domains. Glycemic control was assessed by measures of HbA1c and average blood glucose levels based on 7 days of self-monitoring at baseline and at 6 and 12 months. Relationships between personality traits and measures of glycemic control were examined by correlation and linear regression models that were adjusted for age, sex, race, duration of diabetes, medication status, and experimental treatment. RESULTS: Lower average blood glucose values at baseline were associated with higher scores for the personality domain of neuroticism and several specific traits including anxiety, angry hostility depression, self-consciousness, and vulnerability but were associated with lower scores for the trait of altruism. Results were similar for HbA1c but were not as strong. Follow-up results were similar but were less consistent. CONCLUSIONS: Personality traits may offer new insights into variations in glycemic control in patients with type 2 diabetes undergoing standard management. The relative tendency to experience fewer negative emotions and to focus on the needs of others instead of oneself could prove to be a risk factor for poor glycemic control.  (+info)

What do the needles, syringes, lancets and reagent strips of diabetic patients become in the absence of a common attitude? About 1070 questionnaires in diabetic clinics. (30/768)

The aim was to investigate the fate of injection and monitoring material after its use by diabetic patients in different countries (France, Belgium, Luxemburg, Switzeland and Tunisia). Some suitable containers are available for disposal but little is known about the attitudes of patients and physicians to them. 1 070 questionnaires were completed by patients (age: 50 +/- 18 years; diabetes duration: 15 +/- 11 years; 2.8 +/- 1.1 injections per day) visiting 109 doctors. Injections were done at home (72.6%), or both at home and at work (26.6%). At home: needles, syringes, lancets and reagent strips were thrown directly into the bin in 46.9%, 49.9%, 52.2% and 67.6% of cases, respectively; and in a closed plastic bottle in 29. 6%, 28.5%, 28.9% and 19.9% of cases, respectively. Specific containers were used in 8.6% and 6.3% of cases for needles and syringes, respectively. 62% of the bottles and containers were thrown directly into the bin, whereas 15.5% were returned to a pharmacy (4.5% taken to hospitals, 2.9% were burned). At work: 63% of the patients brought their needles and syringes home for disposal, 6.9% kept suitable containers at work and 30% threw their materials directly into local bins. We conclude that awareness should be increased and the organization of the collection of used material improved.  (+info)

Effect of intensive glycemic control on microalbuminuria in type 2 diabetes. Veterans Affairs Cooperative Study on Glycemic Control and Complications in Type 2 Diabetes Feasibility Trial Investigators. (31/768)

OBJECTIVE: Microalbuminuria can reflect the progress of microvascular complications and may be predictive of macrovascular disease in type 2 diabetes. The effect of intensive glycemic control on microalbuminuria in patients in the U.S. who have had type 2 diabetes for several years has not previously been evaluated. RESEARCH DESIGN AND METHODS: We randomly assigned 153 male patients to either intensive treatment (INT) (goal HbA(1c) 7.1%) or to standard treatment (ST) (goal HbA(1c) 9.1%; P = 0.001), and data were obtained during a 2-year period. Mean duration of known diabetes was 8 years, mean age of the patients was 60 years, and patients were well matched at baseline. We obtained 3-h urine samples for each patient at baseline and annually and defined microalbuminuria as an albumin:creatinine ratio of 0.03-0.30. All patients were treated with insulin and received instructions regarding diet and exercise. Hypertension and dyslipidemia were treated with similar goals in each group. RESULTS: A total of 38% of patients had microalbuminuria at entry and were evenly assigned to both treatment groups. INT retarded the progression of microalbuminuria during the 2-year period: the changes in albumin:creatinine ratio from baseline to 2 years of INT versus ST were 0.045 vs. 0.141, respectively (P = 0.046). Retardation of progressive urinary albumin excretion was most pronounced in those patients who entered the study with microalbuminuria and were randomized to INT. Patients entering with microalbuminuria had a deterioration in creatinine clearance at 2 years regardless of the intensity of glycemic control. In the group entering without microalbuminuria, the subgroup receiving ST had a lower percentage of patients with a macrovascular event (17%) than the subgroup receiving INT (36%) (P = 0.03). Use of ACE inhibitors or calcium-channel blockers was similarly distributed among the groups. CONCLUSIONS: Intensive glycemic control retards microalbuminuria in patients who have had type 2 diabetes for several years but may not lessen the progressive deterioration of glomerular function. Increases in macrovascular event rates in the subgroup entering without albuminuria who received INT remain unexplained but could reflect early worsening, as observed with microvascular disease in the Diabetes Control and Complications Trial.  (+info)

Glucoweb: a case study of secure, remote biomonitoring and communication. (32/768)

As the Internet begins to play a greater role in many healthcare processes, it is inevitable that remote monitoring of patients' physiological parameters over the Internet will become increasingly commonplace. Internet-based communication between patients and their healthcare providers has already become prevalent, and has gained significant attention in terms of confidentiality issues. However, transmission of data directly from patients' physiological biomonitoring devices over the Web has garnered significantly less focus, especially in the area of authentication and security. In this paper, we describe a prototype system called Glucoweb, which allows patients with diabetes mellitus to transmit their self-monitored blood glucose data directly from their personal glucometer device to their diabetes care provider over the Internet. No customized software is necessary on the patient's computer, only a Web browser and active Internet connection. We use this example to highlight key authentication and security measures that should be considered for devices that transmit healthcare data to remote locations.  (+info)