Masks
Laryngeal Masks
A type of oropharyngeal airway that provides an alternative to endotracheal intubation and standard mask anesthesia in certain patients. It is introduced into the hypopharynx to form a seal around the larynx thus permitting spontaneous or positive pressure ventilation without penetration of the larynx or esophagus. It is used in place of a facemask in routine anesthesia. The advantages over standard mask anesthesia are better airway control, minimal anesthetic gas leakage, a secure airway during patient transport to the recovery area, and minimal postoperative problems.
Respiratory Protective Devices
Respirators to protect individuals from breathing air contaminated with harmful dusts, fogs, fumes, mists, gases, smokes, sprays, or vapors.
Intubation, Intratracheal
A procedure involving placement of a tube into the trachea through the mouth or nose in order to provide a patient with oxygen and anesthesia.
Perceptual Masking
Air Pressure
The force per unit area that the air exerts on any surface in contact with it. Primarily used for articles pertaining to air pressure within a closed environment.
Manikins
In the medical field, manikins are realistic, full-size models of human bodies used for teaching and practicing medical skills, such as CPR, intubation, or surgical procedures, as they provide a realistic and safe training environment without the use of actual patients.
Fiber Optic Technology
Anesthesia, General
Positive-Pressure Respiration
A method of mechanical ventilation in which pressure is maintained to increase the volume of gas remaining in the lungs at the end of expiration, thus reducing the shunting of blood through the lungs and improving gas exchange.
Laryngoscopy
Examination, therapy or surgery of the interior of the larynx performed with a specially designed endoscope.
Respiration, Artificial
Any method of artificial breathing that employs mechanical or non-mechanical means to force the air into and out of the lungs. Artificial respiration or ventilation is used in individuals who have stopped breathing or have RESPIRATORY INSUFFICIENCY to increase their intake of oxygen (O2) and excretion of carbon dioxide (CO2).
Germ Layers
Cricoid Cartilage
Airway Obstruction
Any hindrance to the passage of air into and out of the lungs.
Respiratory Insufficiency
Drama
Smear Layer
Adherent debris produced when cutting the enamel or dentin in cavity preparation. It is about 1 micron thick and its composition reflects the underlying dentin, although different quantities and qualities of smear layer can be produced by the various instrumentation techniques. Its function is presumed to be protective, as it lowers dentin permeability. However, it masks the underlying dentin and interferes with attempts to bond dental material to the dentin.
Anesthesia, Inhalation
Protective Clothing
Tidal Volume
The volume of air inspired or expired during each normal, quiet respiratory cycle. Common abbreviations are TV or V with subscript T.
Oxygen Inhalation Therapy
Contrast Sensitivity
Inhalation Spacers
Noninvasive Ventilation
Techniques for administering artificial respiration without the need for INTRATRACHEAL INTUBATION.
Aerosols
Photic Stimulation
Pressure
Psychophysics
Laryngismus
A disorder in which the adductor muscles of the VOCAL CORDS exhibit increased activity leading to laryngeal spasm. Laryngismus causes closure of the VOCAL FOLDS and airflow obstruction during inspiration.
Larynx
Retina
The ten-layered nervous tissue membrane of the eye. It is continuous with the OPTIC NERVE and receives images of external objects and transmits visual impulses to the brain. Its outer surface is in contact with the CHOROID and the inner surface with the VITREOUS BODY. The outer-most layer is pigmented, whereas the inner nine layers are transparent.
Neuromuscular Blockade
The intentional interruption of transmission at the NEUROMUSCULAR JUNCTION by external agents, usually neuromuscular blocking agents. It is distinguished from NERVE BLOCK in which nerve conduction (NEURAL CONDUCTION) is interrupted rather than neuromuscular transmission. Neuromuscular blockade is commonly used to produce MUSCLE RELAXATION as an adjunct to anesthesia during surgery and other medical procedures. It is also often used as an experimental manipulation in basic research. It is not strictly speaking anesthesia but is grouped here with anesthetic techniques. The failure of neuromuscular transmission as a result of pathological processes is not included here.
Intermittent Positive-Pressure Ventilation
Application of positive pressure to the inspiratory phase when the patient has an artificial airway in place and is connected to a ventilator.
Anesthesia
Eye Protective Devices
Epiglottis
A thin leaf-shaped cartilage that is covered with LARYNGEAL MUCOSA and situated posterior to the root of the tongue and HYOID BONE. During swallowing, the epiglottis folds back over the larynx inlet thus prevents foods from entering the airway.
Air
Intubation
Visual Cortex
Nebulizers and Vaporizers
Devices that cause a liquid or solid to be converted into an aerosol (spray) or a vapor. It is used in drug administration by inhalation, humidification of ambient air, and in certain analytical instruments.
Neurons
Retinal Ganglion Cells
Neurons of the innermost layer of the retina, the internal plexiform layer. They are of variable sizes and shapes, and their axons project via the OPTIC NERVE to the brain. A small subset of these cells act as photoreceptors with projections to the SUPRACHIASMATIC NUCLEUS, the center for regulating CIRCADIAN RHYTHM.
Materials Testing
Pattern Recognition, Visual
Microscopy, Electron, Scanning
Microscopy in which the object is examined directly by an electron beam scanning the specimen point-by-point. The image is constructed by detecting the products of specimen interactions that are projected above the plane of the sample, such as backscattered electrons. Although SCANNING TRANSMISSION ELECTRON MICROSCOPY also scans the specimen point by point with the electron beam, the image is constructed by detecting the electrons, or their interaction products that are transmitted through the sample plane, so that is a form of TRANSMISSION ELECTRON MICROSCOPY.
Cross-Over Studies
Studies comparing two or more treatments or interventions in which the subjects or patients, upon completion of the course of one treatment, are switched to another. In the case of two treatments, A and B, half the subjects are randomly allocated to receive these in the order A, B and half to receive them in the order B, A. A criticism of this design is that effects of the first treatment may carry over into the period when the second is given. (Last, A Dictionary of Epidemiology, 2d ed)
Airway Management
Immobilization
Subliminal Stimulation
Pneumonia, Aspiration
Surface Properties
Continuous Positive Airway Pressure
A technique of respiratory therapy, in either spontaneously breathing or mechanically ventilated patients, in which airway pressure is maintained above atmospheric pressure throughout the respiratory cycle by pressurization of the ventilatory circuit. (On-Line Medical Dictionary [Internet]. Newcastle upon Tyne(UK): The University Dept. of Medical Oncology: The CancerWEB Project; c1997-2003 [cited 2003 Apr 17]. Available from: http://cancerweb.ncl.ac.uk/omd/)