Validation of the Rockall risk scoring system in upper gastrointestinal bleeding. (1/3865)

BACKGROUND: Several scoring systems have been developed to predict the risk of rebleeding or death in patients with upper gastrointestinal bleeding (UGIB). These risk scoring systems have not been validated in a new patient population outside the clinical context of the original study. AIMS: To assess internal and external validity of a simple risk scoring system recently developed by Rockall and coworkers. METHODS: Calibration and discrimination were assessed as measures of validity of the scoring system. Internal validity was assessed using an independent, but similar patient sample studied by Rockall and coworkers, after developing the scoring system (Rockall's validation sample). External validity was assessed using patients admitted to several hospitals in Amsterdam (Vreeburg's validation sample). Calibration was evaluated by a chi2 goodness of fit test, and discrimination was evaluated by calculating the area under the receiver operating characteristic (ROC) curve. RESULTS: Calibration indicated a poor fit in both validation samples for the prediction of rebleeding (p<0.0001, Vreeburg; p=0.007, Rockall), but a better fit for the prediction of mortality in both validation samples (p=0.2, Vreeburg; p=0.3, Rockall). The areas under the ROC curves were rather low in both validation samples for the prediction of rebleeding (0.61, Vreeburg; 0.70, Rockall), but higher for the prediction of mortality (0.73, Vreeburg; 0.81, Rockall). CONCLUSIONS: The risk scoring system developed by Rockall and coworkers is a clinically useful scoring system for stratifying patients with acute UGIB into high and low risk categories for mortality. For the prediction of rebleeding, however, the performance of this scoring system was unsatisfactory.  (+info)

Performance and specificity of monoclonal immunoassays for cyclosporine monitoring: how specific is specific? (2/3865)

BACKGROUND: Immunoassays designed for the selective measurement of cyclosporin A (CsA) inadvertently show cross-reactivity for CsA metabolites. The extent and clinical significance of the resulting overestimation is controversial. A comprehensive assessment of old and new methods in clinical specimens is needed. METHODS: In a comprehensive evaluation, CsA was analyzed in 145 samples with the new CEDIA assay and compared with the Emit assay with the old and new pretreatments, the TDx monoclonal and polyclonal assays, the AxSYM, and HPLC. All samples were from patients with liver and/or kidney transplants. RESULTS: The CEDIA offered the easiest handling, followed by the AxSYM, which showed the longest calibration stability. The TDx monoclonal assay provided the lowest detection limit and the lowest CVs. The mean differences compared with HPLC were as follows: Emit, 9-12%; CEDIA, 18%; AxSYM, 29%; and TDx monoclonal, 57%. The CycloTrac RIA paralleled the Emit results. In contrast to the mean differences, substantial (>200%) and variable overestimations of the CsA concentration were observed in individual patient samples. Metabolic ratios, estimates of the overall concentrations of several cross-reacting metabolites (nonspecific TDx polyclonal/specific reference method), correlated with the apparent biases of the various monoclonal assays. Metabolic ratios varied up to 10-fold, which translated into biases for individual samples between -7% and +174%. The higher the cross-reactivity of an assay was, the higher was the range of biases observed. The interindividual differences markedly exceeded other factors of influence (organ transplanted, hepatic function). CONCLUSION: Because assay bias cannot be predicted in individual samples, substantially erratic CsA dosing can result. The specificity of CsA assays for parent CsA remains a major concern.  (+info)

TE671 cell-based ELISA for anti-acetylcholine receptor antibody determination in myasthenia gravis. (3/3865)

BACKGROUND: Acetylcholine receptor (AChR) from human muscles is the antigen used currently in radioimmunoprecipitation assays (RIPAs) for the determination of anti-AChR antibodies in the diagnosis of myasthenia gravis (MG). Our aim was to develop and validate an ELISA using TE671 cells as the source of AChR. METHODS: After TE671 cell homogenization, the crude AChR extract was used for plate coating. Anti-AChR antibodies were determined in 207 MG patients and in 77 controls. RESULTS: The mean intra- and interassay CVs (for two samples with different anti-AChR antibody concentrations) were 9.7% and 15.7%, respectively. Test sensitivity and specificity, for generalized MG, were 79.5% (95% confidence interval, 72.8-85.0%) and 96.1% (89.0-99.1%). The detection limit was 2 nmol/L. Anti-AChR antibody concentrations from 53 MG patients, as tested with our ELISA, showed good agreement with an RIPA with a mean difference (SD) of 1.0 (5.6) nmol/L. CONCLUSION: Our ELISA is a simple screening test for the diagnosis of MG and enables rapid and inexpensive patient follow-up.  (+info)

LocaLisa: new technique for real-time 3-dimensional localization of regular intracardiac electrodes. (4/3865)

BACKGROUND: Estimation of the 3-dimensional (3D) position of ablation electrodes from fluoroscopic images is inadequate if a systematic lesion pattern is required in the treatment of complex arrhythmogenic substrates. METHODS AND RESULTS: We developed a new technique for online 3D localization of intracardiac electrodes. Regular catheter electrodes are used as sensors for a high-frequency transthoracic electrical field, which is applied via standard skin electrodes. We investigated localization accuracy within the right atrium, right ventricle, and left ventricle by comparing measured and true interelectrode distances of a decapolar catheter. Long-term stability was analyzed by localization of the most proximal His bundle before and after slow pathway ablation. Electrogram recordings were unaffected by the applied electrical field. Localization data from 3 catheter positions, widely distributed within the right atrium, right ventricle, or left ventricle, were analyzed in 10 patients per group. The relationship between measured and true electrode positions was highly linear, with an average correlation coefficient of 0.996, 0.997, and 0.999 for the right atrium, right ventricle, and left ventricle, respectively. Localization accuracy was better than 2 mm, with an additional scaling error of 8% to 14%. After 2 hours, localization of the proximal His bundle was reproducible within 1.4+/-1.1 mm. CONCLUSIONS: This new technique enables accurate and reproducible real-time localization of electrode positions in cardiac mapping and ablation procedures. Its application does not distort the quality of electrograms and can be applied to any electrode catheter.  (+info)

European interlaboratory comparison of breath 13CO2 analysis. (5/3865)

The BIOMED I programme Stable Isotopes in Gastroenterology and Nutrition (SIGN) has focused upon evaluation and standardisation of stable isotope breath tests using 13C labelled substrates. The programme dealt with comparison of 13C substrates, test meals, test conditions, analysis techniques, and calculation procedures. Analytical techniques applied for 13CO2 analysis were evaluated by taking an inventory of instrumentation, calibration protocols, and analysis procedures. Two ring tests were initiated measuring 13C abundances of carbonate materials. Evaluating the data it was found that seven different models of isotope ratio mass spectrometers (IRMS) were used by the participants applying both the dual inlet system and the continuous flow configuration. Eight different brands of certified 13C reference materials were used with a 13C abundance varying from delta 13CPDB -37.2 to +2.0/1000. CO2 was liberated from certified material by three techniques and different working standards were used varying from -47.4 to +0.4/1000 in their delta 13CPDB value. The standard deviations (SDs) found for all measurements by all participants were 0.25/1000 and 0.50/1000 for two carbonates used in the ring tests. The individual variation for the single participants varied from 0.02 /1000 (dual inlet system) to 0.14/1000 (continuous flow system). The measurement of the difference between two carbonates showed a SD of 0.33/1000 calculated for all participants. Internal precision of IRMS as indicated by the specifications of the different instrument suppliers is < 0.3/1000 for continuous flow systems. In this respect it can be concluded that all participants are working well within the instrument specifications even including sample preparation. Increased overall interlaboratory variation is therefore likely to be due to non-instrumental conditions. It is possible that consistent differences in sample handling leading to isotope fractionation are the causes for interlaboratory variation. Breath analysis does not require sample preparation. As such, interlaboratory variation will be less than observed for the carbonate samples and within the range indicated as internal precision for continuous flow instruments. From this it is concluded that pure analytical interlaboratory variation is acceptable despite the many differences in instrumentation and analytical protocols. Coordinated metabolic studies appear possible, in which different European laboratories perform 13CO2 analysis. Evaluation of compatibility of the analytical systems remains advisable, however.  (+info)

The length and eruption rates of incisor teeth in rats after one or more of them had been unimpeded. (6/3865)

The eruption rate and length of all four incisor teeth in rats were measured under ether anaesthesia by recording the position of marks on their labial surfaces at 2-day intervals, using calibrated graticules in microscope eyepieces. The rats were divided into four groups and either a lower, an upper, both a lower and an upper, or no incisors were unimpeded. This paper describes the changes when the unimpeded incisors returned to the occlusion. Neither the unimpeded nor the impeded incisors simply returned to control values immediately the period of unimpeded eruption ended, but showed transient changes in their lengths and eruption rates. The results confirm that eruption rates are determined by the sum of the lengths of the lower and upper incisors, rather than by their own lengths, with longer teeth erupting more slowly. Specifically, restoring the bevel to the incisors did not slow their eruption below normal impeded rates. The slowing of the eruption of the longer of two adjacent incisors was related to the length differences of the incisors in the same jaw, not to the sum of the differences in both jaws. Contact with the contralateral incisor in the opposite jaw slowed the eruption of an incisor more than contact with the ipsilateral incisor.  (+info)

Fluorimetric determination of aluminum traces in hemodialysis solutions using Mordant Red 19. (7/3865)

A sensitive and accurate method for the spectrofluorimetric determination of trace levels of aluminum in hemodialysis solutions using Mordant Red 19 as the complexation reagent has been developed. The optimal experimental conditions for the concentration of fluorimetric reagent, pH, temperature, and the specific type of matrix are reported. The emission of the fluorescent metal chelate was measured at 555 nm, excitation at 478 nm. Linearity between emission intensity and aluminum concentration was found in the 2-20 ppb range in standard aluminum solutions. Limit of detection was 0.4 ppb. The aluminum amounts in some commercial hemodialysis solutions were determined by means of the extrapolation method. The proposed method proved to be suitable in terms of sensitivity and accuracy for the determination of aluminum in dialysis fluids.  (+info)

Determination of tin, vanadium, iron, and molybdenum in various matrices by atomic absorption spectrometry using a simultaneous liquid-liquid extraction procedure. (8/3865)

An atomic-absorption spectrometric method is described for the determination of tin, vanadium, iron, and molybdenum in two certified reference materials, food samples, and petroleum crude. After treatment with acids, these elements are separated from matrix elements by simultaneous solvent extraction of 5,5'-methylenedisalicylohydroxamic acid complexes from HCl/NaClO4 solution into an isobutyl methyl ketone/tributyl phosphate solution. The detection limits range from 0.018 to 0.19 microg/mL (n = 3), and the relative standard deviations do not exceed 2.0% at levels of 0.5, 0.6, 2.0, and 7.0 microg/mL of Fe, Mo, V, and Sn, respectively. The method is selective and suffers only from interference by Zr(IV), Ti(IV), Th(IV), W(VI), PO4(3-), and F-.  (+info)