Single-plate Molteno implants in complicated glaucomas: results, survival rates, and complications. (1/13)

Sixty-two single-plate single-stage Molteno implantations for complicated glaucomas were performed between March 1991 and November 1992. The charts of all these patients were reviewed to determine the intraocular pressure (IOP) control success rate (< 21 mm Hg with or without medications), visual success rate (retention or improvement of visual acuity from preoperative level) and the rate of complications encountered. A Kaplan-Meier life-table (survival) analysis was also performed. IOP control was obtained in 74.2% of cases. Mean postoperative IOP was 16.97 +/- 8.07 mm Hg (Mean +/- SD). Visual success was obtained in 51.6% of the eyes. Eyes with aphakia/pseudophakic glaucomas showed the best response with 80% of them achieving IOP control and 60% achieving visual success. The survival plot for IOP control revealed 75.81% and 74.19% success rates at 48 and 72 weeks, respectively. Complications encountered were either due to the early postoperative hypotony or were tube-related. These results were gratifying considering the severity of the glaucoma in these cases and they reaffirm the usefulness of the Molteno implant in the management of difficult glaucomas.  (+info)

Survival analysis for success of Molteno tube implants. (2/13)

AIM: To apply survival analysis in assessing the long term outcome of Molteno tube implantation and to identify risk factors for failure. METHODS: A retrospective, 10 year, consecutive case series study of 119 eyes that underwent implantation of a Molteno tube. The main outcome measures considered were intraocular pressure (IOP), visual acuity, and complications. RESULTS: A 30% or greater reduction in IOP was achieved in 68.9% of cases. However, the overall, "complete success" rate (IOP <22 mm Hg with no medications) after a mean (SD) follow up period of 43 (33) months (range 6-120) was only 33.6% despite a fall in mean (SD) IOP from 38.2 (8.2) mm Hg to 20.1 (11.0) mm Hg. The "qualified success" rate (IOP <22 mm Hg with or without medications) was 60.5%. Failure was most common in the first postoperative year but could occur after several years, the survival curve having an exponential shape. The only statistically significant risk factor for failure identified was pseudophakia, although eyes with neovascular glaucoma tended to fare poorly. Postoperative IOP tended to be lower after double plate than after single plate implantation. There was no significant difference in outcome based on age, sex, race, previous penetrating keratoplasty, or previous conjunctival surgery. CONCLUSIONS: In eyes at high risk of trabeculectomy failure, implantation of an aqueous shunt device should be considered. Pseudophakia should be considered an additional risk factor for failure. Early failure appeared relatively more common but long term follow up of all cases is recommended to ensure adequate management of late failures.  (+info)

Otago Glaucoma Surgery Outcome Study: long term results of cataract extraction combined with Molteno implant insertion or trabeculectomy in primary glaucoma. (3/13)

BACKGROUND/AIMS: To describe the long term results of cases of cataract extraction combined with either Molteno implant insertion or trabeculectomy for primary open angle glaucoma. METHODS: This prospective case series followed cases which had cataract extraction and Molteno implant insertion (45 eyes) or trabeculectomy (94 eyes) followed up for a mean of 5.3 years and 3.9 years respectively. RESULTS: Cataract extraction and Molteno implant insertion or trabeculectomy controlled the intraocular pressure at 21 mmHg or less with a probability of 1.00 (95% CI 0.93 to 1.00) at 10 years or more after operation and 0.94 (95% CI 0.89 to 0.99) and 0.73 (95% CI 0.46 to 0.99) at five and 10 years after operation respectively. CONCLUSIONS: Cataract extraction combined with insertion of Molteno implants or trabeculectomy controlled the intraocular pressure in 100% (45/45) and 94% (88/94) of cases respectively.  (+info)

Outcome of graft free Molteno tube insertion. (4/13)

AIMS: To determine the long term outcome of Molteno implants inserted using a modified surgical technique that eliminates the need for a donor scleral graft. METHODS: Retrospective case series involving a medical record analysis of 35 consecutive patients undergoing first Molteno implant surgery for refractory glaucoma. The main outcomes included life table analysis of intraocular pressure control following surgery and frequency of intraoperative and postoperative complications. RESULTS: There were no complications related specifically to the modified method of tube placement. Medium term intraocular pressure control was similar to other series. CONCLUSIONS: This simplified method for the insertion of Molteno implants eliminates the need for a donor scleral graft while maintaining the implant's ability to control intraocular pressure.  (+info)

Location of glaucoma drainage devices relative to the optic nerve. (5/13)

BACKGROUND: Limited data are available to guide optimal positioning of glaucoma drainage devices (GDD) in relation to the limbus and optic nerve. The authors aim to provide guidelines for appropriate and safe GDD implantation. METHOD: The optimal positioning of five different GDD were evaluated using necropsy eyes of varying axial lengths. The dependent variable that was measured was the maximum distance that a GDD could be placed posterior to the limbus while remaining 2 mm away from the optic nerve. RESULTS: The average maximum distance posterior to the limbus of the anterior plate edge ranged between 9.0-15.0 mm in the superotemporal quadrant for the GDD tested. The distances for superonasal, inferonasal, and inferotemporal quadrants ranged between 8.0-14.0 mm, 9.0-14.0 mm, and 11.0-17.0 mm, respectively. The Molteno device could be placed most posteriorly while remaining 2 mm away from the nerve. The Ahmed FP7 and S2 were the least amenable to posterior placement before encroaching on the 2 mm limit. CONCLUSION: The maximum distance that a GDD can be placed posterior to the limbus, before encroachment around the optic nerve, varies between different devices and quadrants of placement. Taking a measurement of the exact distance of the plate from the limbus during GDD surgery is recommended.  (+info)

Otago glaucoma surgery outcome study: cytology and immunohistochemical staining of bleb capsules around Molteno implants. (6/13)

PURPOSE: To describe the cytology and immunohistochemistry of Molteno implant capsules from cases of primary and secondary glaucoma. METHODS: Histologic features of capsules including cell cytology, the distribution of activated (proliferating) cells, apoptosing cells, and membrane bound vesicles (presumed death messengers) were assessed by light microscopy and correlated with clinicopathological features in 10 noninflamed eyes with good intraocular pressure control (nine autopsy and one enucleation) obtained from 2 months to 16.8 years after insertion of Molteno implants. RESULTS: All bleb capsules demonstrated two distinct layers. The thin external layer was cellular with fairly numerous small blood vessels coursing through normally staining, regularly arranged collagen fibers. The thicker, deeper layer was avascular, relatively acellular, and characterized by regularly arranged swollen and fragmented collagen fibers. Most cells in the external layer appeared normal; however, between 5% (in recently formed blebs) and approximately 50% (in well established blebs) showed cytological and/or immunohistochemical changes characteristic of metabolic activation and/or apoptosis. All cells in the deeper layer, regardless of time after surgery, also demonstrated cytological and/or immunohistochemical staining characteristic of metabolic activation and/or apoptosis. In addition, the deeper layer evidenced large numbers of minute membrane-bound vesicles (presumed death messengers). CONCLUSIONS: The balance between activation and apoptosis regulates the thickness and permeability of bleb capsules, and the normal lifecycle of bleb capsules includes continual inner surface degeneration and external surface renewal.  (+info)

Otago glaucoma surgery outcome study: tissue matrix breakdown by apoptotic cells in capsules surrounding molteno implants. (7/13)

 (+info)

Otago Glaucoma Surgery Outcome Study: the pattern of expression of MMPs and TIMPs in bleb capsules surrounding Molteno implants. (8/13)

 (+info)